The text of a manual · part 8 of 21
Gryphon Reference Manual: 4 Configuration, pages 62 to 71
Pages 62 to 71 of 183, from Gryphon Reference Manual
The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic D100 and Datalogic M100
Page 62
PEN EMULATION The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes.
OPERATING MODE interpret mode
Interprets commands without sending them to the decoder.
transparent mode i<-k i<-k i<-k Sends commands to the decoder without interpreting them.
52
Page 63
Enter configuration i i
Exit and Save Configuration
PEN EMULATION k k
MINIMUM OUTPUT PULSE high resolution code emulation
200 µs i%( =k i%( =k i%( =k 400 µs i%(@k i%(@k i%(@k
600 µs
800 µs i%( Fk i%( Fk i%( Fk
1 ms i%(-Ik i%(-Ik i%(-Ik 1.2 ms low resolution code emulation
See par. 5.2.1 for details.
53
Page 64
Enter configuration i i
Exit and Save Configuration
PEN EMULATION k k
CONVERSION TO CODE 39 AND CODE 128 ► disable conversion to Code 39 i%" 1k i%" 1k i%" 1k Transmits codes in their original format.
enable conversion to Code 39 i%"4k i%"4k i%"4k Converts codes read into Code 39 format.
enable conversion to Code 128
Converts codes read into Code 128 format. ► = default value for GRYPHON™ D Series readers = default value for GRYPHON™ M Series readers See par. 5.2.2 for details.
54
Page 65
Enter configuration i i
Exit and Save Configuration
PEN EMULATION k k
OVERFLOW narrow i%) ?k i%) ?k i%) ?k medium i%)Bk i%)Bk i%)Bk wide
See par. 5.2.3 for details.
OUTPUT LEVEL normal (white = logic level 0)
i%% 7k i%% 7k i%% 7k inverted (white = logic level 1)
i%%:k i%%:k i%%:k
See par. 5.2.4 for details.
55
Page 66
Enter configuration i i
Exit and Save Configuration
PEN EMULATION
IDLE LEVEL normal (black level)
i%& 9k i%& 9k i%& 9k inverted (white level)
i%&<k i%&<k i%&<k
See par. 5.2.4 for details.
INTER-BLOCK DELAY delay between character blocks transmitted to Host
☞ i$, k i$, k i$, k
Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from .1 to 9.9 seconds DELAY disabled See par. 5.2.5 for details
56 k k
Page 67
DATA FORMAT NOT FOR PEN INTERFACES
CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR FIELD ADJUSTMENT FIELD ADJ. CHARACTER CODE LENGTH TX CHARACTER REPLACEMENT ADDRESS STAMPING ADDRESS DELIMITER
1. 2.
Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups.
☞
= Read the code and follow the procedure given = Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
57
Page 68
DATA FORMAT
CODE IDENTIFIER TABLE CODE
AIM STANDARD
DATALOGIC STANDARD
2/5 interleaved 2/5 industrial 2/5 normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 with 2 ADD ON EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON EAN 13 with 5 ADD ON UPC A with 2 ADD ON UPC A with 5 ADD ON UPC E with 2 ADD ON UPC E with 5 ADD ON Code 39 Code 39 Full ASCII CODABAR ABC CODABAR Code 128 EAN 128 ISBT 128 Code 93 CIP/39 CIP/HR Code 32 MSI Plessey Standard Plessey Anker Telepen Delta IBM Code 11 Code 16K Code 49 PDF417 RSS Expanded Linear and Stacked RSS Limited RSS 14 Linear and Stacked
]Iy ]Xy ]Sy ]Xy ]E4 ]E0 ]Xy ]Xy ]E5 ]E6 ]E1 ]E2 ]Xy ]Xy ]Xy ]Xy ]Ay ]Ay ]Fy ]Xy ]Cy ]Cy ] C4 ]Gy ]Xy ]Xy ]Xy ]My ]P0 ]P1 ]X0 ]X0 ]Hy ]K0 ]Ty ]L0 ]e0 ]e0 ]e0
N P O Q A B C D J K L M F G H I V W R S T k f U Y e X Z a o d c b p q r t v u
58
Custom
Page 69
DATA FORMAT •
AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options (check digit tested or not, check digit tx or not, etc.).
•
When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled).
•
The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character.
•
Write in the Custom character identifiers in the table above for your records.
59
Page 70
Enter configuration i i
Exit and Save Configuration
DATA FORMAT CODE IDENTIFIER disable i&# 4k i&# 4k i&# 4k
Datalogic standard ik ik ik
AIM standard custom i&# =k i&# =k i&# =k
60 k k
Page 71
Enter configuration i i
Exit and Save Configuration
DATA FORMAT k k
CUSTOM CODE IDENTIFIER define custom code identifier(s)
☞
Read the above code. (Code Identifiers default to Datalogic standard, see table on previous page). Select the code type from the code table in Appendix B for the identifier you want to change.
You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step : valid characters are in the range 00-FD.
Example:
To define Code 39 Code Identifier = @ define custom code identifier(s)
Read i&' i&' k k
Code 39
+ i78k i78k
+
40
+
FF
61