The text of a manual · part 7 of 21
Gryphon Reference Manual: 4 Configuration, pages 52 to 61
Pages 52 to 61 of 183, from Gryphon Reference Manual
The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic D100 and Datalogic M100
Page 52
Enter Configuration i i
Exit and Save Configuration
USB-KBD CONTROL CHARACTER EMULATION
CTRL+ Shift + Key i'0 Ok i'0 Ok i'0 Ok
CTRL + Key i'0Rk i'0Rk i'0Rk
42 k k
Page 53
WEDGE PARAMETERS All GRYPHON™ D Series readers + GRYPHON™ M/OM-GRYPHON™ configurations only
KEYBOARD NATIONALITY CAPS LOCK CAPS LOCK AUTO-RECOGNITION NUM LOCK INTER-CHARACTER DELAY INTER-CODE DELAY KEYBOARD SETTING WEDGE CONTROL CHARACTER EMULATION
1. 2.
Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups.
☞
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
43
Page 54
Enter configuration i i
Exit and Save Configuration
WEDGE k k
KEYBOARD NATIONALITY Belgian
English i'+-Qk i'+-Qk i'+-Qk French
German i'+ Nk i'+ Nk i'+ Nk Italian i'+Hk i'+Hk i'+Hk Spanish
Swedish
USA i'+ Ek i'+ Ek i'+ Ek
The Japanese Keyboard Nationality selection is valid only for IBM AT compatible PCs. Japanese
44
Page 55
Enter configuration i i
Exit and Save Configuration
WEDGE k k
CAPS LOCK caps lock OFF i'& ;k i'& ;k i'& ;k caps lock ON i'&>k i'&>k i'&>k Select the appropriate code to match your keyboard caps lock status. Note: Caps lock manual configuration is ignored when Caps Lock Auto-Recognition is enabled. For PC Notebook interface selections, the caps lock status is automatically recognized, therefore this command is not necessary.
CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable i'1 Qk i'1 Qk i'1 Qk enable i'1Tk i'1Tk i'1Tk
45
Page 56
Enter configuration i i
Exit and Save Configuration
WEDGE k k
NUM LOCK toggle num lock i'-Lk i'-Lk i'-Lk num lock unchanged i'- Ik i'- Ik i'- Ik This selection is used together with the Alt Mode interface selection for AT or Notebook PCs. It changes the way the Alt Mode procedure is executed, therefore it should be set as follows: • if your keyboard Num Lock is normally on use num lock unchanged
• if your keyboard Num Lock is normally off use toggle num lock
In this way the device will execute the Alt Mode procedure correctly for your application.
INTER-CHARACTER DELAY delay between characters transmitted to Host
☞ i$, k i$, k i$, k
Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds delay disabled
46
Page 57
Enter configuration i i
Exit and Save Configuration
WEDGE k k
INTER-CODE DELAY delay between codes transmitted to Host
☞
Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 seconds delay disabled
47
Page 58
Enter configuration i i
Exit and Save Configuration
WEDGE k k
KEYBOARD SETTING ALPHANUMERIC KEYBOARD SETTING The reader can be used with terminals or PCs with various keyboard types and nationalities through a simple keyboard setting procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Keyboard setting consists of communicating to the reader how to send data corresponding to the keyboard used in the application. The keys must be set in a specific order. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys.
Example: If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Each pressed and released key must generate an acoustic signal on the reader, otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Backspace" to correct a wrong key entry. In this case the reader emits 2 beeps. Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK". setting the alphanumeric keyboard
☞ i'# 5k i'# 5k i'# 5k
Read the code above. Press the keys shown in the following table according to their numerical order. Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to the various national symbologies. In this case: •
The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with keys not used, or substituted with each other.
• characters can be substituted with other single symbols (e.g. "SPACE") even if not included in the barcode set used.
• characters can be substituted with others corresponding to your keyboard. The reader signals the end of the procedure with 2 beeps indicating the keys have been registered.
48
Page 59
WEDGE 01 : Shift 02 : Alt 03 : Ctrl 04 : Backspace 05 : SPACE 06 : ! 07 : " 08 : # 09 : $ 10 : % 11 : & 12 : ' 13 : ( 14 : ) 15 : * 16 : + 17 : , 18 : 19 : . 20 : / 21 : 0 22 : 1 23 : 2 24 : 3 25 : 4 26 : 5 27 : 6
28 : 7 29 : 8 30 : 9 31 : : 32 : ; 33 : < 34 : = 35 : > 36 : ? 37 : @ 38 : A 39 : B 40 : C 41 : D 42 : E 43 : F 44 : G 45 : H 46 : I 47 : J 48 : K 49 : L 50 : M
51 : N 52 : O 53 : P 54 : Q 55 : R 56 : S 57 : T 58 : U 59 : V 60 : W 61 : X 62 : Y 63 : Z 64 : [ 65 : \ 66 : ] 67 : ^ 68 : _ (underscore) 69 : ` 70 : { 71 : | 72 : } 73 : ~ 74 : DEL
GRYPHON™ M Series Only When working with GRYPHON™ M series readers, the keyboard setup functioning is signaled by the LEDs on the OM-GRYPHON™ cradle. Each key stroke corresponds to a double blinking of the green LED. By pressing the Backspace key the red LED on the OM-GRYPHON™ cradle blinks, while the green LED stays on.
Do not place the reader onto the OM-GRYPHON™ cradle during this procedure. Otherwise, the battery charging will occur modifying the LEDs functioning. CAUTION Once the procedure has been completed, the green LED turns off.
49
Page 60
Enter configuration i i
Exit and Save Configuration
WEDGE CONTROL CHARACTER EMULATION Ctrl + Shift + Key i'0 Ok i'0 Ok i'0 Ok
Ctrl + Key i'0Rk i'0Rk i'0Rk
50 k k
Page 61
PEN EMULATION All GRYPHON™ D Series readers + GRYPHON™ M/OM-GRYPHON™ configurations only
OPERATING MODE MINIMUM OUTPUT PULSE CONVERSION TO CODE 39 OVERFLOW OUTPUT LEVEL IDLE LEVEL INTER-BLOCK DELAY
1. 2.
Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups.
☞
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
51