Page 32

GRYPHON™

4 WEDGE (continued)

IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard). KEY TRANSMISSION MODE make-only keyboard i i i make-break keyboard i i i

KEYBOARD TYPE advanced keyboard i i i typewriter keyboard i i i

22

', ', ',

Page 33

REFERENCES

4 WEDGE (continued) ALT MODE

The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used. You do not need to make a Keyboard Nationality selection. (default = Num Lock Unchanged). Make sure the Num Lock key on your keyboard is ON. IBM AT - ALT mode i i i k k k PC Notebook - ALT mode i i i i i i

WYSE TERMINALS ANSI Keyboard i i i

PC Keyboard

ASCII Keyboard i i i

VT220 style Keyboard i i i

23

Page 34

GRYPHON™

4 WEDGE (continued)

DIGITAL TERMINALS VT2xx/VT3xx/VT4xx i i i

APPLE APPLE ADB Bus i i i

24

Page 35

REFERENCES

4.7

4

USB READER CONFIGURATION

The USB interface is compatible with: Windows 98 (and later) Mac OS 8.0 (and later)

IBM POS for Windows 4690 Operating System

USB Start-up As with all USB devices, upon connection, the Host performs several checks by communicating with the USB device. During this phase the LED on the device blinks and normal operations are suspended. Two basic conditions must be met before the USB device is ready to read codes, the correct USB driver must be loaded and sufficient power must be supplied to the reader. For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). If the Host supplies sufficient power to the reader, the start-up phase ends correctly, the LED stops blinking and the reader emits the beep OK signal. If the Host does not supply sufficient power to the reader, a dialog box will appear on the Host and the reader will be blocked (LED continues blinking). In this case, disconnect the USB device cable at the Host (LED stops blinking), connect and power-up an external supply to the USB device cable then reconnect the USB device cable to the Host and close the dialog box. The reader emits the beep OK signal. You can now read codes. At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web page http://www.datalogic.com/services/support/. The reader is ready.

25

Page 36

GRYPHON™

4

First Start-Up Connect device to Host with USB cable

LED blinks

Load drivers (if requested)

LED off

Disconnect reader at Host

YES

Connect external power supply to cable and power up

BEEP OK

Does a dialog box appear asking whether Bus power is sufficient? NO LED off - BEEP OK Select desired USB interface code

Reconnect reader cable to Host and close dialog box

Load drivers (if requested)

Read test codes. Reader is READY

Successive start-ups will automatically recognize the previously loaded drivers. If external power is used, verify that external power is already supplied.

Successive Start-Ups Connect device to Host with USB cable

Disconnect reader at Host

Connect external power supply to cable and power up

YES

LED blinks

Does a dialog box appear asking whether Bus power is sufficient? NO LED off - BEEP OK

BEEP OK

26

Reconnect reader cable to Host and close dialog box

Read test codes. Reader is READY

Page 37

REFERENCES

4 USB USB-KBD i i i

6" 6" 6"

USB-KBD-ALT-MODE i i i

6" 6" 6"

USB-KBD-APPLE i i i

6" 6" 6" i i i

6" 6" 6"

USB-COM*

USB-IBM-Table Top i i i

6" 6" 6" k k k

USB-IBM-Hand Held i i i

*

6" 6" 6"

When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web page (see http://www.datalogic.com/services/support/).

27

Page 38

GRYPHON™

4

4.8

CHANGING DEFAULT SETTINGS

Once your reader is setup, you can change the default parameters to meet your application needs. Refer to the preceding paragraphs for initial configuration in order to set the default values and select the interface for your application. In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group. The RS232, WEDGE, PEN EMULATION groups are for Standard Interface parameter configuration for all GRYPHON™ D series readers and GRYPHON™ M/OM-GRYPHON™ Stand Alone configurations only: The USB group is for GRYPHON™ D USB only.

The following parameter groups are common to all interface applications: DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulation. POWER SAVE manages overall current consumption in the reading device. READING PARAMETERS control various operating modes and indicator status functioning. DECODING PARAMETERS maintain correct barcode decoding in certain special reading conditions. CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options. ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced formatting of messages towards the Host. It cannot be used with Pen Emulation connections. RADIO PARAMETERS (M series only) allow configuration of radio control parameters.

28

Page 39

RS232 PARAMETERS All GRYPHON™ D Series readers + GRYPHON™ M/OM-GRYPHON™ configurations only

BAUD RATE PARITY DATA BITS STOP BITS HANDSHAKING ACK/NACK PROTOCOL FIFO INTER-CHARACTER DELAY RX TIMEOUT SERIAL TRIGGER LOCK (D-SERIES ONLY)

1. 2.

Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups.

☞

= Read the code and follow the procedure given = Default value

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

29

Page 40

Enter configuration i i

Exit and Save Configuration

RS232 k k

BAUD RATE 150 baud i$% 6k i$% 6k i$% 6k 300 baud i$%9k i$%9k i$%9k 600 baud

1200 baud i$% ?k i$% ?k i$% ?k 2400 baud i$%-Bk i$%-Bk i$%-Bk 4800 baud

9600 baud

19200 baud

38400 baud

30

Page 41

Enter configuration i i

Exit and Save Configuration

RS232 k k

PARITY none i$$ 4k i$$ 4k i$$ 4k even parity i$$7k i$$7k i$$7k odd parity

DATA BITS 7 bits i$" 0k i$" 0k i$" 0k

8 bits i$"3k i$"3k i$"3k

9 bits

31