The text of a manual · part 4 of 21
Gryphon Reference Manual: 4 Configuration, pages 22 to 31
Pages 22 to 31 of 183, from Gryphon Reference Manual
The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic D100 and Datalogic M100
Page 22
GRYPHON™
4
4
CONFIGURATION
4.1
CONFIGURATION METHODS
4.1.1
Reading Configuration Barcodes
This manual can be used for complete setup and configuration of your reader by following the setup procedures in this chapter (see par. 4.2 for an overview). If you wish to change the default settings, this manual provides complete configuration of your reader in an easy way. To configure your reader:
1) Open the folded page in Appendix C with the hex-numeric table and keep it open during the device configuration.
2) Read the Enter Configuration code ONCE, available at the top of each page of configuration.
3) Modify the desired parameters in one or more sections following the procedures given for each group.
4) Read the Exit and Save Configuration code ONCE, available at the top of each page of configuration. Reference notes describing the operation of the more complex parameters are given in chapter 5.
4.1.2
Using DL Sm@rtSet
DL Sm@rtSet is a Windows-based utility program providing a quick and user-friendly configuration method via the RS232 interface. It also allows upgrading the software of the connected device (see the DL Sm@rtSet User's Manual for more details).
4.1.3
Copy Command
A previously configured device (Master), can be used to send its configuration directly to other devices of the same type (Slaves). The particular procedure for each device is given in par. 5.9.
12
Page 23
REFERENCES
4.1.4
4
Sending Configuration Strings from Host
An alternative configuration method is provided in Appendix A using the RS232 interface. This method is particularly useful when many devices need to be configured with the same settings. Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily.
4.2
SETUP PROCEDURES
For GRYPHON™ D-Series readers, follow the setup procedures in pars. 4.3 and 4.6. For GRYPHON™ D-Series USB readers, follow the setup procedures in par. 4.7. For GRYPHON™ M-Series readers, the setup procedures depend on two basic applications, Stand Alone or STAR-System™. Stand Alone applications allow communication with the Host by either the OM-GRYPHON™ cradle (par. 4.4), or by the STAR-Modem™ radio modem (par. 4.4.2). STAR-System™ applications allow communication with the Host through an RS485 network by the STARGATE™ RF base station or by the STAR-Modem™ radio modem (par. 4.5). Proceed as shown in the following diagram: B e g in S etu p b y choosin g the setup proced ure for your G R Y P H O N ™ reade r as indica ted belo w.
GRYPHON™ D
G RYPHO N™ D USB
P ar. 4.3 P ar. 4.6
P ar. 4 .7
S tan d Alo n e Ap p lica tio n s
S T AR -S ys tem ™ Ap p licatio n s
G R Y P H O N ™ M /O M -G R Y P H O N ™
G R Y P H O N ™ M /S T AR -S ystem ™
P ar. 4.4 P ar. 4.6
P ar. 4 .5
O p tio n a l P ar. 4.4.1
• ST AR G AT E™ • ST AR -M odem ™ in ST AR -System ™ Mode m ultiple g uns per O M -G R Y P H O N ™
G R Y P H O N ™ M /S T AR -M o dem ™ in S tand A lon e M od e P ar. 4.4.2
E n d o f S etu p Y ou r read er is now ready to read ba rcodes u sing the de fault settings.
13
Page 24
GRYPHON™
4
4.3
GRYPHON™ D SETUP
1.
Read the restore default parameters code below. Restore GRYPHON™ D Default i i i
Pk Pk Pk
After reading the above code, go to par. 4.6 Interface Selection.
4.4
GRYPHON™ M/OM-GRYPHON™ STAND ALONE SETUP Read the restore default parameters code below.
1.
Restore GRYPHON™M Default i i i
Pk Pk Pk
Read the codes below to set the radio address of the GRYPHON M reader.
2.
Enter configuration i i i
3.
Set Radio Address i3" 3')k i3" 3')k i3" 3')k
+ four digits for the GRYPHON™ M Address (from 0000 to 1999). All readers used in the same area must have different addresses.
4.
Exit and Save configuration
14 k k k
Page 25
REFERENCES
5.
4
Read the Bind code to pair the GRYPHON™ M to the OM-GRYPHON™ cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following paragraph 4.4.1, ‘Using Multiple M Series Readers with Same Cradle'. Bind i i i
3/ 3/ 3/
The green LED on the GRYPHON™ M will blink; the reader is ready to be positioned onto the cradle.
6.
Firmly position the reader onto the OM-GRYPHON™ cradle within 10 seconds, a beep will be emitted, signaling that the OM-GRYPHON™ cradle has been paired to the GRYPHON™ M, and the green LED on the reader will go off.
Green LED
7.
Read the OM-GRYPHON™ restore default code: Restore OM-GRYPHON™ default i i i
39 39 39
Go to par. 4.6 Interface Selection.
15
Page 26
GRYPHON™
4
4.4.1
Using Multiple M-Series Readers With Same Cradle
If you want to use several M-Series readers with the same OM-GRYPHON™ cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join (step 5). Join
5. i i i
The green LED on the GRYPHON™ M will blink: the reader is ready to be positioned onto the cradle. Complete step 6.
END of procedure. If the cradle is not Bound to a reader, its address assumes a random value which can cause conflicts and malfunctions to other cradles within its range. CAUTION
YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.8.
16
Page 27
REFERENCES
4.4.2
4
GRYPHON™ M/STAR-Modem™ in Stand Alone Mode
To configure a GRYPHON™ M reader to communicate with STAR-Modem™ in Stand Alone Mode, follow the procedure in par. 4.4 substituting steps 4 and 5 with those below: STAR-Modem™ Address
4.
i343k i343k i343k
Read the code above and the four-digit address of the STAR-Modem™.
5.
Exit and Save configuration k k k
END of procedure. YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.8.
17
Page 28
GRYPHON™
4
4.5
GRYPHON™ M/STAR-SYSTEM™ SETUP
The following procedure allows configuring a GRYPHON™ M reader to communicate with various STAR-System™ devices such as STARGATE™ RF base stations.
1.
Restore GRYPHON™ M Default i i i
2.
Enter configuration i i i
3.
Pk Pk Pk
Set the connection according to the length of the codes to be read: Code Length ≤240 Characters i3"Bk i3"Bk i3"Bk
Code Length >240 Characters
4.
Set Radio Address
+ four digits from the Numeric Table in the range 0000-1999. All readers must have different addresses.
18
Page 29
REFERENCES
4 First STAR-System™ Address
5.
i343k i343k i343k
Read the code above and the four-digit address of the First STAR-System™ device in the system.
Set Last STAR-System™ Address
6.
i355k i355k i355k
Read the code above and the four-digit address of the Last STAR-System™ device in the system.
Whenever the system is composed of a single base station, the first and last base station addresses (steps 5 and 6) must have the same value. NOTE
Exit and Save Configuration
7.
k k k
END of procedure. YOUR READER IS NOW READY TO READ BARCODES. To change the defaults see par. 4.8.
19
Page 30
GRYPHON™
4
4.6
INTERFACE SELECTION
Read the interface selection code for your application. RS232 Standard i i i
$1 $1 $1
POS Terminals Nixdorf Mode A i i i i i i i i i
$. $. $.
Fujitsu
ICL Mode
For POS terminal default settings refer to par. 5.11.
PEN i i i
20
Page 31
REFERENCES
4 WEDGE IBM AT or PS/2 PCs i i i i i i i i i i i i
IBM XT
PC Notebook
IBM SURE1
IBM Terminal 3153 i i i
21