Page 122
Exit and Save Configuration
ADVANCED FORMATTING k k
Divide Code into Fields
5 divide code into fields
☞
Read one number in the range 1 to 5 to divide the code into fields.
Define Code Fields
6 define code fields Each code field length can be set by either: a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field. OR BY b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match. OR BY c) specifying a specific character length up to the maximum of 99 characters.
OR BY d) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will not be transmitted.
112
Page 123
Exit and Save Configuration
ADVANCED FORMATTING k k
DEFINE FIELD 1 BY: EITHER field separator a)
☞ i)( Ak i)( Ak i)( Ak
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator i k i k i k
OR match character b)
☞ i)( Jk i)( Jk i)( Jk
Read the match character from the HEX table. Range of characters = 01-FE. OR field length c)
☞ i)(Dk i)(Dk i)(Dk
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
☞
AND Field 1 Terminators no field terminators
1 field terminator
☞ i))Fk i))Fk i))Fk i)) Ck i)) Ck i)) Ck
2 field terminators
☞
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE.
113
Page 124
Exit and Save Configuration
ADVANCED FORMATTING k k
DEFINE FIELD 2 BY: EITHER field separator a)
☞ i)( Ak i)( Ak i)( Ak
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator i k i k i k
OR match character b)
☞ i)( Jk i)( Jk i)( Jk
Read the match character from the HEX table. Range of characters = 01-FE. OR field length c)
☞ i)(Dk i)(Dk i)(Dk
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
☞
AND Field 2 Terminators no field terminators
1 field terminator
☞ i))Fk i))Fk i))Fk i)) Ck i)) Ck i)) Ck
2 field terminators
☞
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE.
114
Page 125
Exit and Save Configuration
ADVANCED FORMATTING k k
DEFINE FIELD 3 BY: EITHER field separator a)
☞ i)( Ak i)( Ak i)( Ak
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator i k i k i k
OR match character b)
☞ i)( Jk i)( Jk i)( Jk
Read the match character from the HEX table. Range of characters = 01-FE. OR field length c)
☞ i)(Dk i)(Dk i)(Dk
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
☞
AND Field 3 Terminators no field terminators
1 field terminator
☞ i))Fk i))Fk i))Fk i)) Ck i)) Ck i)) Ck
2 field terminators
☞
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE.
115
Page 126
Exit and Save Configuration
ADVANCED FORMATTING k k
DEFINE FIELD 4 BY: EITHER field separator a)
☞ i)( Ak i)( Ak i)( Ak
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator i k i k i k
OR match character b)
☞ i)( Jk i)( Jk i)( Jk
Read the match character from the HEX table. Range of characters = 01-FE. OR field length c)
☞ i)(Dk i)(Dk i)(Dk
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
☞
AND Field 4 Terminators no field terminators
1 field terminator
☞ i))Fk i))Fk i))Fk i)) Ck i)) Ck i)) Ck
2 field terminators
☞
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE.
116
Page 127
Exit and Save Configuration
ADVANCED FORMATTING k k
DEFINE FIELD 5 BY: EITHER field separator a)
☞ i)( Ak i)( Ak i)( Ak
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator i k i k i k
OR match character b)
☞ i)( Jk i)( Jk i)( Jk
Read the match character from the HEX table. Range of characters = 01-FE. OR field length c)
☞ i)(Dk i)(Dk i)(Dk
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
☞
AND Field 5 Terminators no field terminators
1 field terminator
☞ i))Fk i))Fk i))Fk i)) Ck i)) Ck i)) Ck
2 field terminators
☞
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE.
117
Page 128
Exit and Save Configuration
ADVANCED FORMATTING 7 k k
First Additional Fixed Field no fixed field i)* Ek i)* Ek i)* Ek 1 character fixed field
☞ i)*Hk i)*Hk i)*Hk 2 character fixed field
☞
3 character fixed field
☞ i)* Nk i)* Nk i)* Nk
4 character fixed field
☞ i)*-Qk i)*-Qk i)*-Qk 5 character fixed field
☞
6 character fixed field
☞
After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. Example: 4 Character Fixed Field
+ 4D + 41 + 49 + 4E =
118
MAIN
Page 129
Exit and Save Configuration
ADVANCED FORMATTING 8 k k
Second Additional Fixed Field no fixed field i)+ Gk i)+ Gk i)+ Gk 1 character fixed field
☞ i)+Jk i)+Jk i)+Jk 2 character fixed field
☞
3 character fixed field
☞ i)+ Pk i)+ Pk i)+ Pk
4 character fixed field
☞ i)+-Sk i)+-Sk i)+-Sk 5 character fixed field
☞
6 character fixed field
☞
After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. Example: 3 Character Fixed Field
+ 53 + 45 + 54 =
SET
119
Page 130
Exit and Save Configuration
ADVANCED FORMATTING k k
Field Transmission
9 number of fields to transmit
Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1 field 2 k k k field 3 i -k i -k i -k field 4 field 5 additional field 1 additional field 2
Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit
Field 2
+4+
120
Additional Field 1
+
Field 1
+
Field 2
+
Page 131
Exit and Save Configuration
ADVANCED FORMATTING 10 k k
Standard Formatting do not apply standard formatting i)- Kk i)- Kk i)- Kk apply standard formatting i)-Nk i)-Nk i)-Nk After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted.
11
End Format Definition end Format 1 definition i). Mk i). Mk i). Mk end Format 2 definition i).Pk i).Pk i).Pk end Format 3 definition end Format 4 definition i). Vk i). Vk i). Vk
121