Page 112
Enter configuration i i
Exit and Save Configuration
CODE SELECTION k k
CODE 16K disable the code i"+ @k i"+ @k i"+ @k
Code 16K i"+Ck i"+Ck i"+Ck To read stacked codes, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief "ticks" indicates that reading is proceeding correctly.
CODE 49 disable the code i". Fk i". Fk i". Fk
Code 49 i".Ik i".Ik i".Ik To read stacked codes, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief "ticks" indicates that reading is proceeding correctly.
102
Page 113
Enter configuration i i
Exit and Save Configuration
CODE SELECTION k k
PDF417 Only PDF417 series readers disable the code i"3 Pk i"3 Pk i"3 Pk
PDF417 i"3Sk i"3Sk i"3Sk
To read stacked codes, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief "ticks" indicates that reading is proceeding correctly.
103
Page 114
Enter configuration i i
Exit and Save Configuration
CODE SELECTION k k
RSS CODES disables the family i"2 Nk i"2 Nk i"2 Nk DISABLE CODE ENABLE CODE disable RSS Expanded Linear and Stacked i"2 *k i"2 *k i"2 *k enable RSS Expanded Linear and Stacked i"2.k i"2.k i"2.k disable RSS Limited
-k -k -k enable RSS Limited disable RSS 14 Linear and Stacked i"2 0k i"2 0k i"2 0k enable RSS 14 Linear and Stacked i"2 4k i"2 4k i"2 4k To read the stacked version of these codes, simply move the reader over the code so that each line of the code is scanned.
104
Page 115
ADVANCED FORMATTING NOT FOR PEN INTERFACES
CONCATENATION ADVANCED FORMATTING
Please follow the setup procedure carefully for these parameters. NOTE
1. 2.
Read the Enter Configuration code ONCE, available at the top of page . Read configuration codes precisely following the numbered procedure given.
☞
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of page.
105
Page 116
Enter configuration i i
Exit and Save Configuration
ADVANCED FORMATTING k k
CONCATENATION disable i&* Bk i&* Bk i&* Bk enable i&*Ek i&*Ek i&*Ek Permits the concatenation of two codes defined by code type and length. It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires. The order of transmission is CODE 1-CODE 2. Define Concatenation
1
Code 1 code ID
☞ i&, Fk i&, Fk i&, Fk Read the code type from the Code Identifier Table beginning in Appendix B. code length
☞ i&- Hk i&- Hk i&- Hk Read a number in the range 01-99 from the Hex/Numeric Table.
106
Page 117
Exit and Save Configuration
ADVANCED FORMATTING 2 k k
Code 2 code ID
☞ i&,Ik i&,Ik i&,Ik Read the code type from the Code Identifier Table beginning in Appendix B. code length
☞ i&-Kk i&-Kk i&-Kk Read a number in the range 01-99 from the Hex/Numeric Table.
3
Concatenation Result Code ID use code 1 ID i&/ Lk i&/ Lk i&/ Lk use code 2 ID i&/Ok i&/Ok i&/Ok Since you can concatenate codes from different families, you must select the Code ID character of the resulting code. The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).
4
Concatenation Timeout timeout
☞ i&+ k i&+ k i&+ k Read two numbers in the range 00 to 99 00= no timeout 01-99 = timeout from 1 to 99 seconds
107
Page 118
Exit and Save Configuration
ADVANCED FORMATTING 5 k k
Transmission after Timeout no code transmitted after timeout i&. Jk i&. Jk i&. Jk only code 1 transmitted (if read) after timeout i&.Mk i&.Mk i&.Mk only code 2 transmitted (if read) after timeout either code 1 or code 2 transmitted after timeout i&. Sk i&. Sk i&. Sk Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection.
108
Page 119
ADVANCED FORMATTING ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria which you will define in the following procedure. Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure: Read the Enter Configuration Command Step 1 Begin Format Definition 1, 2, 3, or 4 Steps 2 - 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 - 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step 10 Apply or Not Standard Message Formatting Step 11 End Format Definition 1, 2, 3, or 4 YES
Define another? NO
Enable Advanced Formats 1, 2, 3, 4 Define No Match Result Read the Exit and Save Configuration Command
109
Page 120
Enter configuration i i
1
Exit and Save Configuration
ADVANCED FORMATTING k k
Begin Format Definition begin Format 1 definition
☞ i)" 5k i)" 5k i)" 5k begin Format 2 definition
☞ i)"8k i)"8k i)"8k begin Format 3 definition
☞ begin Format 4 definition
☞ i)" >k i)" >k i)" >k
2
Match Code Type match code type
☞
Read the above code + the code type to match from the Code Identifier Table in Appendix B. OR any code type i)# 7k i)# 7k i)# 7k
3
Match Code Length match code length
☞ i)$ i)$ i)$ k k k
Read the above code + two numbers in the range 01 to 99 for the exact code length. OR any code length i)$ k i)$ k i)$ k
110
Page 121
Exit and Save Configuration
ADVANCED FORMATTING k k
Match with Predefined Characters
4 no match i)% )& ak i)% )& ak i)% )& ak OR match with 1 character
☞ i)%>k i)%>k i)%>k match with a 2-character string
☞ match with a 3-character string
☞ i)% Dk i)% Dk i)% Dk match with a 4-character string
☞ i)%-Gk i)%-Gk i)%-Gk
After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 01-FE. Example: Match code with the 2-character predefined string = "@@". Match with a 2-character string
+ 40 + 40
Read
AND
☞ position of first character in predefined string i)& i)& i)& k k k
Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found. Read 00 if the match string can be found in any character position.
111