Page 31
EXAMPLE Sets Serial Port COM1 to RS232, 9600 baud, no parity, 8 data bits, 1 stop bit.
Command from PLC
Response from CM900
MSB
LSB
Remarks
MSB
LSB
Remarks
01H
10H
COM1 port, perform Command 10
01H
10H
Port echo, Command echo
FFH
FFH
Message Terminator
00H
E8H
Set Interface Type to RS232
25H
80H
Set Baud Rate to 9600
00H
01H
Set Parity to none
00H
08H
Set Data Bits to 8
00H
01H
Set Stop Bits to 1
FFH
FFH
Message Terminator
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
27
Page 32
Command 11 (11 Hex): Serial Port Block Read DESCRIPTION Read a specified number of bytes from a specific serial port. DISCUSSION The Serial Port Block Read command is used to read a given quantity of bytes from the specified serial port. Remember that there is a maximum of 100 registers of data that can be passed through the backplane interface per read, resulting in 198 bytes of ASCII data that can be transferred, with an additional two bytes used to transmit the command. Unlike the RFID read and write commands, the serial read command will return data in the MSB of the registers. This allows for more data to be transferred from the connected serial device. There is an optional delay for serial input that can be included in the command. The delay is measured in increments of 5 milliseconds. The CM900 will try for the specified delay period to read from the serial port. The CM900 will not accept any other command while it is waiting to accept serial data in the port. EXAMPLE Reads nine bytes of data from serial port COM1, with a 400 (0190H) x 5 milliseconds = 2 second delay.
Command from PLC
Response from CM900
MSB
LSB
Remarks
MSB
LSB
Remarks
01H
11H
COM1 port, perform Command 11
01H
11H
Port echo, Command echo
00H
09H
Read 9 bytes
44H
41H
Read Data 1 & 2 = ’DA’ (44H, 41H)
01H
90H
2 second delay
54H
41H
00H
00H
Terminating Character
Read Data 3 & 4 = ’TA’ (54H, 41H)
4CH
4FH
FFH
FFH
Message Terminator
Read Data 5 & 6 = ’LO’ (4CH, 4FH)
47H
49H
Read Data 7 & 8 = ’GI’ (47H, 49H)
43H
00H
Read Data 9 = ’C’ (43H)
FFH
FFH
Message Terminator
28
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
Page 33
Command 12 (12 Hex): Serial Port Block Write DESCRIPTION Write a specified number of bytes to a specific serial port. DISCUSSION The Serial Port Block Write command is used to write a given quantity of bytes to the specified serial port. Remember that there is a maximum of 100 registers of data that can be passed through the backplane interface per read. Unlike the RFID read and write commands, the serial write command utilizes the MSB as well as the LSB of the registers. This allows for more data to be transferred to the connected serial device. EXAMPLE Write 8 bytes of data to serial port COM1.
Command from PLC
Response from CM900
MSB 01H
MSB
LSB
Remarks
01H
12H
Port echo, Command echo
FFH
FFH
Message Terminator
LSB 12H
42H
42H
52H
20H
43H
4FH
44H
45H
FFH
FFH
Remarks COM1 port, perform Command 12 Write Data 1 & 2 = ’BA’ (42H, 41H) Write Data 3 & 4 = ’R ’ (52H, 20H) Write Data 5 & 6 = ’CO’ (43H, 4FH) Write Data 7 & 8 = ’DE’ (44H, 45H) Message Terminator
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
29
Page 34
Command 13 (13 Hex): Clear Serial Port DESCRIPTION This command is used to clear the 256K byte serial buffer on the specified CM900 serial port. DISCUSSION This command has a time out value to ensure that if a stream of data is being sent to the CM900, the CM900 will not delay clearing the buffer too long. EXAMPLE The following example will clear the 256K buffer on serial COM1, the Clear Serial Buffer Command cannot exceed 2 seconds. Command from PLC
Response from CM900
MSB 01H
MSB
LSB
Remarks
01H
13H
Port echo, Command echo
FFH
FFH
Message Terminator
LSB 13H
01H
90H
FFH
FFH
30
Remarks COM1 port, perform Command 13 Command time out (0190H x 5 ms = 2 sec.) Message Terminator
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
Page 35
Command 20 (20 Hex): Posted Block Write DESCRIPTION This command posts an RF Block Write on the antenna port. DISCUSSION The antenna is polled for twenty milli-seconds every program scan of the CM900. Bit 2 is set to indicate that a Posted Block Write is in progress. When an RF tag moves within range of the polling antenna the Block Write will be complete. As the posted write is completed, bit 0 is set, and bit 2 is cleared. See page 35 for information on the Status Byte. Note: If another command is called during the polling that takes two seconds or longer to complete, i.e. a serial command with a two second time-out, the antenna will not get polled for the time required by that command.
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
31
Page 36
EXAMPLE The following command will post a contiguous Block Write on the antenna port. When a tag comes into range of Antenna 0, starting at address 10 dec on the tag it will write 3 hex, E hex, and A hex in consecutive addresses. Command from PLC
Response from CM900
MSB 00H
MSB
LSB
Remarks
00H
20H
Port echo, Command echo
FFH
FFH
Message Terminator
LSB 20H
00H
0AH
00H
03H
00H
0DH
00H
0E
00H
0AH
FFH
FFH
32
Remarks ANT port, perform Command 20 Posted Block Write starting Address (10 dec) Posted data to be written at starting address (10 dec) Posted data to be written at starting address plus one (11 dec) Posted data to be written at starting address plus two (12 dec) Posted data to be written at starting address plus three (13 dec) Message Terminator
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
Page 37
Command 21 (21 Hex): Posted Block Read DESCRIPTION This command posts a contiguous Block Read on a Antenna 0. DISCUSSIONS The antenna is polled for twenty milli-seconds every scan of the CM900. Bit 3 will indicate that a posted Block Read is in progress. When an RF tag is within range of the polled antenna, the Block Read will be completed and the data read will be stored in the Posted Read Data Buffer in the CM900. As the posted Block Read is completed, the CM900 will turn on bit 1 and change bit 3. See page 35 for information on the Status Byte. Note: If another command is called during the polling that takes two seconds or longer to complete, i.e. a serial command with a two second time-out, the antenna will not get polled for the time required by that command. EXAMPLE The following command will post a Block Read on the antenna port at address 16 decimal for a length of five bytes. Command from PLC
Response from CM900
MSB 00H
MSB
LSB
Remarks
00H
21H
Port echo, Command echo
FFH
FFH
Message Terminator
LSB 21H
00H
10H
00H
05H
FFH
FFH
Remarks ANT port, perform Command 21 Posted Block Read starting Address (16 dec) Posted Block read length (5 dec) Message Terminator
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
33
Page 38
Command 22 (22 Hex): Read Posted Read Data Buffer DESCRIPTION This command reports the last data to be stored in the buffer by a Posted Block Read command. DISCUSSION CM900 will pass data stored in the buffer from the RF antenna to the PLC and update Status Byte bit 1. EXAMPLE The following example requests the CM900 to read the data collected in the Posted Read Data Buffer from the RF antenna.* Command from PLC
Response from CM900
MSB 00H
LSB 22H
MSB
LSB
Remarks
00H
22H
Port echo, Command echo
FFH
FFH
00H
23H
Data read at starting address (16 dec)
00H
45H
Data read at starting address plus one(17 dec)
00H
BCH
Data read at starting address plus two (18 dec)
00H
DEH
Data read at starting address plus three (19 dec)
00H
98H
Data read at starting address plus four (20 dec)
FFH
FFH
Message Terminator
Remarks RF port, perform Command 22 Message Terminator
* Addresses are from the Post Block Read example on page 33.
34
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
Page 39
Command 23 (23 Hex): Posted Commands Status Byte DESCRIPTION This command reports the status of all posted commands pending or completed for the RF port. DISCUSSION The Status Byte has the following structure: Table 5, Posted Command Status Byte Structure Bit
Value
Description
7
0
Spare - always set to 0
6
0
Spare - always set to 0
5
1
Spare - always set to 1
4
1
Spare - always set to 1
3
0 or 1
Posted Block Read Command in Process Set to 1, After Posted Block Read was requested and before it is completed Reset to 0, After tag moves into range of antenna and Posted Block Read Is completed, Cancel All Posted Operations Command has been requested
2
0 or 1
Posted Block Write Command in Process Set to 1, After Posted Block Write was requested and before it is completed Reset to 0, After tag moves into range of antenna and Posted Block Write Is completed, Cancel All Posted Operations Command has been requested
1
0 or 1
Posted Block Read Complete Set to 1, Requested Posted Block Read was completed, Posted Read Data Buffer ready to read Reset to 0, After Read Posted Block Read Data Buffer has been requested, Cancel All Posted Operations Command has been requested
0
0 or 1
Posted Block Write Complete Set to 1, Requested Posted Block Write was completed Reset to 0, After Status Byte has been requested, When a new posted Write/Read is requested, Cancel All Posted Operations Command has been requested
Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module
35
Page 40
EXAMPLE The following command requests the Posted Status Byte for the RF antenna. Command from PLC
Response from CM900
MSB 00H
MSB
LSB
Remarks
00H
23H
Port echo, Command echo
00H
34H
Status byte for RF antenna
FFH
FFH
Message Terminator
FFH
36
LSB 23H FFH
Remarks ANT port, perform Command 23 Message Terminator