5.5 Command Set Overview The Standard Program recognizes a variety of commands from the PLC for performing reads and writes to the CM900’s ports. The commands are encoded in the least significant byte (LSB) of the first register passed to the CM900 from the PLC. Table 3 lists each command and provides a brief description of its function. Table 3 - Command Set Listing

COMMAND

HEX EQUIVALENT

COMMAND NAME

DIRECT RF 0

00 Hex

1

01 Hex

Idle RF Port Noncontiguous Read

2

02 Hex

RF Port Noncontiguous Write

3

03 Hex

RF Port Configure Noncontiguous Read/Write Addresses

4

04 Hex

RF Port Fill Tag

5

05 Hex

RF Port Block Read

6

06 Hex

RF Port Block Write

SERIAL 10

10 Hex

Serial Port Configure

11

11 Hex

Serial Port Block Read

12

12 Hex

Serial Port Block Write

13

13 Hex

Clear Serial Port

20

20 Hex

Posted Block Write*

21

21 Hex

Posted Block Read*

22

22 Hex

Read Posted Read Data Buffer *

23

23 Hex

Posted Status Byte*

POSTED RF

24 24 Hex Cancel Posted Operations* *Use of Posted Commands requires special considerations. Please consult EMS or your distributor before implementing these commands.

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

17

Page 22

5.6 Command Descriptions Command 0 (00 Hex): Idle DESCRIPTION Sets the command byte to 0. DISCUSSION When a file move has been completed or when RF operations are not needed, the command byte may be set to zero, but this is not required. Alternatively, the new command can overwrite the old command values. Unlike other commands, the CM900 will not respond to the idle command. EXAMPLE Sets the command byte to 0.

Command from PLC

Response from CM900

MSB

LSB

Remarks

None

00H

00H

ANT, perform Command 0

FFH

FFH

Message Terminator

18

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 23

Command 1 (01 Hex): RF Port Noncontiguous Read DESCRIPTION Directs an RFID antenna to perform a Read of noncontiguous data addresses in an RFID tag. DISCUSSION This command is designed to perform noncontiguous address reads from an RFID tag. The data collected from the tag is presented to the PLC through a backplane register transfer. Before a noncontiguous read command can be performed, the addresses must be preconfigured though the use of the configuration command (Command 03). The data will be read in the same sequence as the addresses are originally stored. The data read from the tag is returned in the LSB of the register and the MSB is always 00H. EXAMPLE The following example illustrates a noncontiguous read command issued after the addresses are preconfigured using the example presented with the configuration command (Command 03). It directs the antenna to read and return the data at addresses 0005H, 0100H, 0101H, 04AAH, and 0597H of the tag memory. Command from PLC

Response from CM900

MSB

Remarks

MSB

LSB

Remarks

00H

01H

Port echo, Command echo

00H

10H

Data read at Address 0005H

00H

11H

Data read at Address 0100H

00H

AAH

Data read at Address 0101H

00H

BAH

Data read at Address 04AAH

00H

32H

Data read at Address 0597H

FFH

FFH

Message Terminator

LSB

00H

01H

ANT port, perform Command 1

FFH

FFH

Message Terminator

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

19

Page 24

Command 2 (02 Hex): RF Port Noncontiguous Write DESCRIPTION Directs the RFID antenna to perform a Write to noncontiguous data addresses in an RFID tag. DISCUSSION This command is designed to perform noncontiguous address writes to an RFID tag. Before a noncontiguous write command can be performed, the addresses must be preconfigured-configured using the configuration command (Command 03). This command has the same control structure as the noncontiguous read command, except the port address and command number are followed by the data to be written into the preconfigured addresses on the RFID tag. Since all data is stored in 8-bit data format, the MSB of each data word are set to 00H. Data to be stored is always placed in the LSB of the data word. The data must be written in the same sequence as when configured using the configure command. If the amount of data written by this command does not match the amount of data for which the port was configured, an error response will be received. EXAMPLE The following example illustrates a noncontiguous write command issued after the addresses are preconfigured using the example presented with the configuration command (Command 03). It directs the antenna to write 44H to address 3040H and 67H to address 3042H. Command from PLC

Response from CM900

MSB

LSB

Remarks

MSB

LSB

Remarks

00H

02H

ANT port, perform Command 2

00H

02H

Port echo, Command echo

00H

44H

Write 44H to Write Address 1

FFH

FFH

Message Terminator

00H

67H

Write 67H to Write Address 2

FFH

FFH

Message Terminator

20

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 25

Command 3 (03 Hex): RF Port Configure Noncontiguous R/W Addresses DESCRIPTION Set up all non-contiguous Read/Write data addresses for the RFID port. Must be performed before Commands 1 or 2, or an error will occur. DISCUSSION This command configures the addresses to be accessed on the RFID tag when either a Noncontiguous Read (Command 1) or Noncontiguous Write (Command 2) is directed from the host PLC. No tag or antenna communications are initiated by using this command. A Read Address Terminator, FFF0H, and a Write Address Terminator, FFF1H, are always required, regardless of whether or not both reads and writes are being configured. After the configure command is executed, any sequence of noncontiguous read or write commands can subsequently be executed. When using the Noncontiguous Write command, data must be presented in the same sequence as configured. Likewise, the read command returns data in the same sequence as configured.

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

21

Page 26

EXAMPLE Configures the Noncontiguous Read command for the antenna to read at addresses 0005H, 0100H, 0101H, 04AAH and 0597H, and the Noncontiguous Write command to write at addresses 3040H and 3042H. Command from PLC

Response from CM900

MSB

LSB

Remarks

MSB

LSB

Remarks

00H

03H

ANT port, perform Command 3

00H

03H

Port echo, Command echo

00H

05H

Read Address 1 = 0005H

FFH

FFH

Message Terminator

01H

00H

Read Address 2 = 0100H

01H

01H

Read Address 3 = 0101H

04H

AAH

Read Address 4 = 04AAH

05H

97H

Read Address 5 = 0597H

FFH

F0H

Read Address Terminator

30H

40H

Write Address 1 = 3040H

30H

42H

Write Address 2 = 3042H

FFH

F1H

Write Address Terminator

FFH

FFH

Message Terminator

22

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 27

Command 4 (04 Hex): RF Port Fill Tag DESCRIPTION Fill an RFID tag with a one-byte value over multiple contiguous addresses. DISCUSSION This command is commonly used to clear an RFID tag’s memory. It writes a onebyte value repetitively across a specified range of tag addresses, up to 8K bytes at a time. It should be noted that an 8K byte fill, which occurs at 3000 bytes/second, will supersede any other command to the CM900 for up to 2.6 seconds. The fill function requires one data value byte, a starting address, and a fill length. It will then proceed to fill the tag with the data value byte, starting at the specified start address for the specified number of consecutive bytes. EXAMPLE Writes ’A’ (41H) to the tag starting at address 0005H for the following next consecutive 2048 bytes. Command from PLC

Response from CM900

MSB 00H

LSB 04H

00H 08H

05H 00H

MSB 00H FFH

00H FFH

41H FFH

Remarks ANT port, perform Command 4 Start Address = 0005H Fill Length= 2048 bytes (0800H) Data Value Byte = 41H Message Terminator

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

LSB 04H FFH

Remarks Port echo, Command echo Message Terminator

23

Page 28

Command 5 (05 Hex): RF Port Block Read DESCRIPTION Read a block of data from an RFID tag. DISCUSSION The RF Port Block Read command is used to read segments of data from contiguous areas of tag memory. It is capable of handling up to 98 bytes of data transferred to the PLC with one command, with an additional two bytes used to transmit the command echo. Unlike the noncontiguous reads and writes, the block read does not need a configuration command to precede it. The block read consists of a start address and quantity, followed by the message terminator, FFFFH, as shown below. The data read from the tag is returned in the LSB of the register, and the MSB is always 00H. EXAMPLE: Reads 8 bytes of data from the tag starting at address 0101H. Command from PLC

Response from CM900

MSB 00H

LSB 05H

MSB

LSB

Remarks

00H

05H

Port echo, Command echo

01H 00H

01H 08H

00H

52H

Read Data 1 = 52H

00H

46H

Read Data 2 = 46H

00H

49H

Read Data 3 = 49H

FFH

FFH

00H

44H

Read Data 4 = 44H

00H

20H

Read Data 5 = 20H

00H

54H

Read Data 6 = 54H

00H

61H

Read Data 7 = 61H

00H

67H

Read Data 8 = 67H

FFH

FFH

Message Terminator

24

Remarks ANT port, perform command 5 Start Address = 0101H Read Block Length = 8 bytes (0008H) Message Terminator

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 29

Command 6 (06 Hex): RF Port Block Write DESCRIPTION Write a block of data to an RFID tag. DISCUSSION The RF Port Block Write command is used to write segments of data to contiguous areas of tag memory. It is capable of transferring up to 98 bytes of data transferred from the PLC with one command, with an additional two bytes used to transmit the command. Unlike the noncontiguous reads and writes, the Block Write does not need a configuration command to precede it. The Block Write consists of a start address followed by the data stream to be written to the RFID tag. The data to be written to the tag is contained in the LSB of the register, and the MSB is always 00H. EXAMPLE: Writes 8 bytes of data to the tag starting at address 0400H.

Command from PLC

Response from CM900

MSB

LSB

Remarks

MSB

LSB

Remarks

00H

06H

ANT port, perform Command 6

00H

06H

Port echo, Command echo

FFH

FFH

Message Terminator

04H

00H

Start Address = 0400H

04H

00H

Write Data 1 = 52H

00H

46H

Write Data 2 = 46H

00H

49H

Write Data 3 = 49H

00H

44H

Write Data 4 = 44H

00H

20H

Write Data 5 = 20H

00H

54H

Write Data 6 = 54H

00H

61H

Write Data 7 = 61H

00H

67H

Write Data 8 = 67H

FFH

FFH

Message Terminator

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

25

Page 30

Command 10 (10 Hex): Serial Port Configure DESCRIPTION Sets the serial communication protocol for the Serial Ports COM1 and COM2. Please note that the COM2 port is RS232 only. DISCUSSION This command will set up the serial communication protocol for a specified serial port. Table 4 lists the available serial port configuration options, and the appropriate hex values. The configuration options must be provided in the same order as listed in Table 4 .

Table 4 - Serial Port Protocol Settings Parameter

Hex Equivalent

Interface Type

Parameter

Hex Equivalent

Parity

RS232

00E8H

None

0001H

RS422

01A6H

Even

0002H

Odd

0003H

Baud Rate

Data Bits

300

012CH

8

0008H

600

0258H

7

0007H

1200

04B0H

2400

0960H

Stop Bits

4800

12C0H

1

0001H

9600

2580H

2

0002H

19200

4B00H

2

0002H

26

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module