Page 41

Command 24 (24 Hex): Cancel Posted Operations DESCRIPTION This command cancels all Posted Read/Write commands and sets bits 0 - 3 of the Posted Status Byte to zero. EXAMPLE The following command will cancel all Posted Read/Write commands.

Command from PLC

Response from CM900

MSB 00H

LSB 24H

MSB

LSB

Remarks

00H

24H

Port echo, Command echo

FFH

FFH

FFH

FFH

Message Terminator

Remarks ANT port, perform Command 24 Message Terminator

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

37

Page 42

5.7 Error Codes The Standard Program will return the an error if it encounters a fault during operation. Error codes are returned in the LSB of the second register passed to the PLC. Table 6 lists these hex error codes and their meanings.

Table 6, Error Codes Radio Frequency Error Codes Error Code 01 02 03 04 05 06 08 20 21

Description Non-Contiguous Read has failed Non-Contiguous Write has failed Non-Contiguous Read/Write Configuration has failed Fill Operation has failed Contiguous Block Read has failed Contiguous Block Write has failed Search Tag Operation failed Non-contiguous Read/Write attempted without Pre-Configuration Input Command does not match pre-defined format

Serial Commands Error Codes Error Code 20 21 22 23 24 25 26 27 28 29 2A

38

Description Serial configuration command, invalid mode (232 or 422) Serial configuration command, invalid baud rate (300, 600, 1200, 2400, 4800, 9600, 19200) Serial configuration command, invalid parity assignment (1-none, 2-even, 3odd) Serial configuration command, invalid data bit assignment (7, 8) Serial configuration command, invalid stop bit assignment (1, 2) Serial read command, invalid amount of data to read in (1-124) Serial read command, invalid timeout (1-32, 767) Serial read command, timeout was achieved before data reached the port Serial port clear buffer command, timeout was achieved before the port was cleared, possible data remaining in port Serial port requested does not exist on the CM900 COM2 is configured for RS422 communications

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 43

Table 6 (continued), Error Codes Posted Radio Frequency Error Codes Error Code 51 52 53 54

Description Posted read/write requested was too large (should be less than 100 bytes) Posted command is already active on antenna port one Posted read/write address is out of range Request for posted read buffer where there is no data present to report

Miscellaneous Error Codes Error Code 40 41

Description Port assignment does not match the command assignment End terminator (0xFFF) was not located in the register packet

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

39

Page 44

A APPENDIX: NOTICE OF EMISSIONS A.1 U.S. FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. Changes or modifications not expressly approved by EMS could void the user’s authority to operate this equipment.

A.2 Canadian RFI Regulations This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dens le Reglement sur le brouillage readioelectrique edicte par le ministere des Communications du Canada.

40

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 45

B APPENDIX: SPECIFICATIONS Table 7 shows specifications for the CM900. Table 7 - CM900 Specifications Electrical Backplane - supplied by PLC Supply Voltage Max. Current Front End - external supply required Supply Voltage Max. Current Max. Ripple Internal Memeory Master Microprocessor Application Program Storage Communication with Host Compatibility Interface, 5 VDC ± 5%, 250 mA, 24 VDC ± 5%, 250 mA, 750 mA with RF antenna connected, 2.0% of DC voltage, 32K byte battery-backed static RAM, 32K byte EEPROM, 2K used by system, Modicon Compact 984 PLC, direct-connect to backplane, Modicon proprietary interface

RF Interface RFID Port Name Compatibility Interface Max. Cable Length, ANT, EMS HS500-Series Read/Write RFID antennas, Proprietary EMS RFID interface, 4,000 ft. (1,200 m)

Serial Interface Serial Port Names Compatibility Interface Baud Rate Parity Data Bits Stop Bits, COM1, COM2 (Programming/Debug), Any third party external serial devices, COM1 - RS232/RS422, COM2 - RS232, 300, 600, 1200, 2400, 4800, 9600, 19200, None, Odd, Even, 7 or 8, 1 or 2

Modicon Interface Traffic-Cop Compatibility SP1004 Loadable, CM900 for 6-register transfer, PLC function block allows transfer of 1-100 registers of data between PLC and CM900

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

41

Page 46

Table 7 - CM900 Specifications (continued) Mechanical Specifications Dimensions (W x H x D) Weight Connectors Backplane 22-position plug-in terminal strip LED Indicator, Environment Operating Temp Non-Operating Temp Storage Temp Humidity Shock Resistance Vibration Resistance Altitude ESD Immunity Magnetic Immunity Noise Emissions

42, 1.57 x 5.59 x 4.43 in. (40 x 142 x 112.5 mm), .62 lbs, Direct plug-in to Modicon Compact 984 PLC Housings, 24 VDC, COM1, COM2, ANT, Power, Error, COM1 RX, COM1 TX, COM2 RX, COM2 TX, ANT, +32° to +140° F (0° to +60°C), -40° to +185° F (-40° to +85°C), per IEC 68-2-14, Test Nb, -40° to +185° F (-40° to +85°C), per IEC 68-2-1/2, Test Ab and Bb, 0 to 95% non-condensing, per IEC 68-2-3, Test Ca, 30G for 11 ms, per IEC 68-2-27, Test Ea, 1 G at 3 to 500 Hz for 23 minutes per plane, 1 octave/minute in all three planes per IEC 68-2-6, Test Fc, 15,000 ft. (4,540 m), per MIL-STD-810, Method 500.2, low pressure, 4kV to all surfaces, per IEC 801-2, level tests, Per IEC 801-3, Level 3, FCC Part 15, Subpart B, Class A; CDC Class B

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 47

C APPENDIX: MODELS & ACCESSORIES Table 8 lists the available models and accessories for the CM900. Table 8, Models and Accessories Available Models Part Number

Description

CM900

Automatic Identification module for Modicon 984-A120 Compact and Micro programmable controller. One RFID port for EMS RFID antennas and two serial communications ports for interface to external serial devices.

Accessories Part Number

Description

SP1011-LIB

Software manual and libraries for use in developing custom application programs for the CM900. Diskette includes libraries and standard program source code, does not include C compiler, tools or compiler manual. C programming experience required.

88-1001

Franklin C compiler for CM900 software development

SP1004

Software loadable program for most models of Modicon 984 CPU (excluding 984-A, -B, -X) and most models of the Modicom Compact Series (excluding compact CPU - 120 models). Required to run the standard program.

CBL-1182

Demonstration cable set, includes two 10 ft. long RS232 connection cables to the main (DB-25S) and programming ports (DE-9P), 10 ft. long connection cable for a HS500/HS501antenna, and 24 VDC wall mount power supply. Terminal connectors included.

CBL-1183

Demonstration cable set, includes two 10 ft. long RS232 connection cables to the main (DB-25S) and programming ports (DE-9P), 10 ft. long connection cable for a HS500A/HS501A antenna, and 24 VDC wall mount power supply. Terminal connectors included.

CBL-1184

Cable assembly, PC AT-to-CM900 programming cable, DE-9S to terminal strip. Includes power supply.

CBL-1185

Cable assembly, PC XT-to-CM900 programming cable, DB-25S to terminal strip. Includes power supply.

46-1286

Connector assembly, CM900, for connection to pins 1-11

46-1285

Connector assembly, CM900, for connection to pins 12-22

Replacement Parts 17-1122

Operator’s Manual, CM900 AutoID Interface Module

17-1079

Software Manual, SP1011-LIB

17-1080

Software Manual, SP1004 Software Loadable for the Modicon Compact Series 984/CM900 Interface

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

43

Page 48

D APPENDIX: ASCII CHART

Decimal

Hex

Character

Decimal

Hex

Character

000

00

NUL

032

20

(space)

001

01

SOH

033

21

!

002

02

STX

034

22

’’

003

03

ETX

035

23

#

004

04

EOT

036

24

$

005

05

ENQ

037

25

%

006

06

ACK

038

26

&

007

07

BEL

039

27

‘

008

08

BS

040

28

(

009

09

HT

041

29

)

010

0A

LF

042

2A

*

011

0B

VT

043

2B

+

012

0C

FF

044

2C

’

013

0D

CR

045

2D

-

014

0E

SO

046

2E

.

015

0F

SI

047

2F

/

016

10

DLE

048

30

0

017

11

DC1

049

31

1

018

12

DC2

050

32

2

019

13

DC3

051

33

3

020

14

DC4

052

34

4

021

15

NAK

053

35

5

022

16

SYN

054

36

6

023

17

ETB

055

37

7

024

18

CAN

056

38

8

025

19

EM

057

39

9

026

1A

SUB

058

3A

:

027

1B

ESC

059

3B

;

028

1C

FS

060

3C

<

029

1D

GS

061

3D

=

030

1E

RS

062

3E

>

031

1F

US

063

3F

?

44

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

Page 49

Decimal

Hex

Character

Decimal

Hex

Character

064

40

@

098

62 b

065

41

A

099

63 c

066

42

B

100

64 d

067

43

C

101

65 e

068

44

D

102

66 f

069

45

E

103

67 g

070

46

F

104

68 h

071

47

G

105

69 i

072

48

H

106

6A j

073

49

I

107

6B k

074

4A

J

108

6C l

075

4B

K

109

6D m

076

4C

L

110

6E n

077

4D

M

111

6F o

078

4E

N

112

70 p

079

4F

O

113

71 q

080

50

P

114

72 r

081

51

Q

115

73 s

082

52

R

116

74 t

083

53

S

117

75 u

084

54

T

118

76 v

085

55

U

119

77 w

086

56

V

120

78 x

087

57

W

121

79 y

088

58

X

122

7A z

089

59

Y

123

7B

{

090

5A

Z

124

7C

|

091

5B

[

125

7D

}

092

5C

\

126

7E

~

093

5D

]

127

7F

DEL

094

5E

^

095

5F, 096

60

‘

097

61 a

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module

45

Page 50

Notes:

46

Copyright © 2001, Escort Memory Systems Inc. CM900 AutoID Interface Module