Page 81

The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB

Reserved

LSB

7

6

5

1

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error) flag in the Input file. The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

MSB

17

16

15

0

4

2

1

0

Used by scanner for block transfers 14

Reserved

Word

3

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

1

0

5

4

3

2

Error

Reserved Done

Ack

Digital In

Digital In

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

75

Page 82

HMS MUX32 Tag Fill, Opcode 34 Writes a fill byte to consecutive addresses in the HMS Tag (in range of the specified antenna). When the Slave’s Data Ready bit is set, issue a Collect command (Opcode 39) to retrieve status and data. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

0

LSB

7

6

5

4 Reserved

Word 1

Word 2

11

10

9

8

2

1

0

OPCODE 34 (22H)

MSB

Fill byte

LSB

MUX32 Address of Slave device

3

Task Number

Reserved

Length of fill in bytes

Word 3

Start address in RFID tag

Word 4

Timeout Value (given in 100 ms units, 0 = no timeout)

When the command BTW is complete, set the Initiate bit in the output file.

76

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 83

The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB

Reserved

LSB

7

6

5

1

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error) flag in the Input file. The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

MSB

17

16

15

0

4

2

1

0

Used by scanner for block transfers 14

Reserved

Word

3

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

1

0

5

4

3

2

Error

Reserved Done

Ack

Digital In

Digital In

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

R–eady

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

77

Page 84

3.6.5 General Auto-Polled MUX32 Commands The 40-series Auto-polled MUX32 Read command (opcode 40) polls the entire bus and returns data from the next active device that has data. The 40-Series commands are not compatible and cannot be used in conjunction with 30-Series commands. A Data Ready bit is set in the response from a Read command indicating which device responded, and that the data has been returned. The Data Ready bit is automatically reset by the next Read command issued. The address of the responding device is included in the response message packet with the status of the previously issued MUX32 command. The MUX32 Read command is used in conjunction with the 40-series HMS antenna commands (Read, Write, and Fill) to collect status and data from specified MUX32 slaves; since those commands only post the requested operation, then return immediately. In typical applications, the auto-polled MUX32 Read command would continuously poll the bus while other operations, such as an HMS Tag Read or Write, execute concurrently. Only one Data Ready bit is set at a time using the 40-Series commands.

78

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 85

MUX32 Read (Auto-polled), Opcode 40 Polls the MUX32 bus and returns either when data is received from a responding slave; or when the timeout period expires with no slaves responding. The status and address of the responding slave and the number of bytes returned are included in the response along with the data itself. Two status bytes are returned: The standard response header status indicates status of the Read command itself. The status returned in the BTR response byte 0, indicates MUX32 status of the previously issued command. The command is formatted as follows: Word

MSB

15

14

13

12

0

11

10

9

8

2

1

0

OPCODE 40 (28H) LSB

7

6

5

4

3

Reserved Word 1

Task Number

Reserved

Timeout, in 100 ms units. 0 = no timeout

When the command BTW is complete, set the Initiate bit in the output file. The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB LSB

Reserved 7

6

1

5

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

79

Page 86

Word

LSB

7

6

5

0

4

3

2

1

0

12

11

10

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

Used by scanner for block transfers MSB

17

16

15

14

13 Reserved

Word

LSB

7

6

5

1

4

3

Reserved

MSB

17

16

15

14

13

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error or Timeout) flag in the Input file. The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

0

4

3

MSB

17

16

15

14

Reserved

Word

2

1

0

Used by scanner for block transfers

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

5

4

3

2

1

0

Error

Timeout

Done

Ack

Digital In

Digital In

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

80

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 87

When the DONE flag is detected, issue a Block Transfer Read (BTR) to retrieve the data read from the Tag. The number of words requested can either be an exact number or if you use “0" the CM52 will return all the words retrieved from the last read command. The data will appear in the following format with the first two words used for overhead. Word

MSB

0

Word 1

Word 2

Word 3

15

14

13

12

Reserved LSB

Responding Slave Address

MSB

Length of data in bytes

LSB

Data byte 0

MSB

Data byte 1

LSB

Data byte 2

MSB

Data byte 3

LSB

Data byte 4 etc.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

11

10

9

8

Error

Timeout

Done

Reserved

81

Page 88

MUX32 Write (Auto-Polled), Opcode 41 Writes up to 58 byte of data to the specified MUX32 slave. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

LSB

7

6

5

4

MSB

Length of data in bytes, 1-58 bytes

0

11

1

Word 2

Word 3

9

8

2

1

0

OPCODE 41 (29H) 3

Reserved Word

10

LSB

MUX32 Address

MSB

Data byte 0

LSB

Data byte 1

MSB

Data byte 2

LSB

Data byte 3 etc...

Task Number

Reserved

When the command BTW is complete, set the Initiate bit in the output file. The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB LSB

Reserved 7

6

1

5

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error) flag in the Input file.

82

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 89

The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

0

4

MSB

17

16

15

14

Reserved

Word

3

2

1

0

Used by scanner for block transfers

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

1

5

4

3

2

Digital In

Digital In

Error

Reserved Done

Ack

0

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

83

Page 90

HMS Auto-Polled MUX32 Commands

HMS MUX32 Tag Read (Auto-Polled), Opcode 42 Reads data from the HMS Tag at the antenna specified. Control is returned immediately. The MUX32 command (Opcode 40) should be issued following the Tag read command to retrieve the data and status of the read operation. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

0

11

LSB

7

6

5

4

3

Reserved Word 1

10

9

8

2

1

0

OPCODE 42 (2AH)

MSB

Length of data in bytes

LSB

MUX32 Address

Task Number

Word 2

Start Address in Tag

Word 3

Timeout Value (given in 100 ms units, 0 = no timeout)

Reserved

When the command BTW is complete, set the Initiate bit in the output file. The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB

Reserved

LSB

7

6

1

5

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

84

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module