Page 61

Serial Write, Opcode 12 Writes up to 124 bytes of data to the specified serial port. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

LSB

7

6

5

4

0

11

10

9

8

2

1

0

OPCODE 12 (0CH) 3

Reserved

Task Number

0=COM1 1=COM2

Word 1

Word 2

Word 3

MSB

Reserved

LSB

Number of bytes to write, 1-124 bytes (binary 0000 0001 = 1 byte, etc.)

MSB

Data byte 0

LSB

Data byte 1

MSB

Data byte 2

LSB

Data byte 3 - until the end of the data to be written.

When the command BTW is complete, set the Initiate bit in the output file. The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB

Reserved

LSB

7

6

1

5

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

55

Page 62

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error) flag in the Input file. The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

0

4

3

MSB

17

16

15

14

Reserved

Word

2

1

0

Used by scanner for block transfers

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

1

5

4

3

2

Digital In

Digital In

Error

Reserved Done

Ack

0

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

56

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 63

Clear Serial Buffers, Opcode 14 Clears the Input/Output Serial Buffers for the designated serial port. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

LSB

7

6

5

4

0

11

10

9

8

2

1

0

OPCODE 14 (0EH) 3

Reserved

Task Number

0=COM1 1=COM2

When the command BTW is complete, set the Initiate bit in the output file. The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB LSB

Reserved 7

6

1

5

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error) flag in the Input file.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

57

Page 64

The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

0

4

3

MSB

17

16

15

14

Reserved

Word

2

1

0

Used by scanner for block transfers

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

1

5

4

3

2

Digital In

Digital In

Error

Reserved Done

Ack

0

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

58

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 65

HMS RS232 Commands

HMS Tag Fill (RS232), Opcode 16 Writes a fill byte to consecutive HMS tag address at the specified serial port. You can define as many as 30 different fill fields. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

LSB

7

6

5

4

0

11

10

9

8

2

1

0

OPCODE 16 (10H) 3

Reserved

Task Number

0=COM1 1=COM2

Word 1

MSB

Fill Byte (0-255)

LSB

Number of Fields to Follow (1-30)

Word 2

Timeout Value (in 100 ms units, 0 = no timeout)

Word 3

Field 1: Length (number of bytes)

Word 4

Field 1: Start Address in RFID Tag

Word 5

Field 2: Length (number of bytes)

Word 6

Field 2: Start Address in RFID Tag

Word

Field n: Length (number of bytes)

(n x 2) +1 Word

Field n: Start Address in RFID Tag

(n x 2) +2

When the command BTW is complete, set the Initiate bit in the output file.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

59

Page 66

The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB

Reserved

LSB

7

6

5

1

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error or Timeout) flag in the Input file. The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

MSB

17

16

15

0

4

3

1

0

Used by scanner for block transfers 14

Reserved

Word

2

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

5

4

3

2

1

0

Error

Timeout

Done

Ack

Digital In

Digital In

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

60

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 67

HMS Tag Read (RS232), Opcode 17 Reads data from the HMS Tag at the specified serial port. The total number of data bytes for all fields is 128. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

0

11

10

9

8

2

1

0

OPCODE 17 (11H) LSB

7

6

5

4

3

Reserved

Task Number

0=COM1 1=COM2

Word 1

MSB LSB

Reserved Number of Fields to Follow (1-24)

Word 2

Timeout Value (in 100 ms units, 0 = no timeout)

Word 3

Field 1: Length (number of bytes)

Word 4

Field 1: Start Address in RFID Tag

Word 5

Field 2: Length (number of bytes)

Word 6

Field 2: Start Address in RFID Tag

Word

Field n: Length (number of bytes)

(n x 2) + 1 Word

Field n: Start Address in RFID Tag

(n x 2) + 2

When the command BTW is complete, set the Initiate bit in the output file.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

61

Page 68

The Command Flags bit map is shown below. The address of Word 0 is O:rrg where O indicates the output file, rr is the CM52 rack address and g is the CM52 group assignment. Word 0

Word

LSB

Used by scanner for block transfers

MSB

Reserved

LSB

7

6

5

1

4

3

Reserved

MSB

17

16

15

14

13

2

1

0

Digital

Digital

Initiate

Out 2

Out 1

12

11

10

Reserved

The CM52 will respond by setting the Ack flag when it sees the Initiate flag to signal receipt of the command buffer. When the command is completed the CM52 will set the Done (and possibly Error or Timeout) flag in the Input file. The Response Flags bit map is shown below. The address of Word 0 is I:rrg where I indicates the input file, rr is the CM52 rack address and g is the CM52 group assignment. Word

LSB

7

6

5

MSB

17

16

15

0

4

3

1

0

Used by scanner for block transfers 14

Reserved

Word

2

LSB

7

1

6 Reserved

MSB

13

12

11

10

Task 3

Task 2

Task 1

Task 0

Done

Done

Done

Done

5

4

3

2

1

0

Error

Timeout

Done

Ack

Digital In

Digital In

2

1

17

16

15

14

13

12

11

10

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

MUX32

Addr 07

Addr 06

Addr 05

Addr 04

Addr 03

Addr 02

Addr 01

Addr 00

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

If the CM52 is configured as a 1/2 rack device, the remaining MUX32 status bits will be present in word 2 and word 3.

62

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 69

When the DONE flag is detected, issue a Block Transfer Read (BTR) to retrieve the data read from the Tag. The number of words requested can either be an exact number or if you use “0" the CM52 will return all the words retrieved from the last read command. The data will appear in the following format. A maximum of 128 bytes of data can be retrieved. Word 0

Word 1

Word n

MSB

Data Byte 0

LSB

Data Byte 1

MSB

Data Byte 2

LSB

Data Byte 3

MSB

Data Byte (n x 2)

LSB

Data Byte (n x 2) +1

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

63

Page 70

HMS Tag Write (RS232), Opcode 18 Writes data to the HMS Tag at the specified serial port. A maximum of 118 bytes can be written using a single field. Reduce the data payload by 2 bytes for each additional field definition. The Block Transfer Write is formatted as follows: Word

MSB

15

14

13

12

0

11

10

9

8

2

1

0

OPCODE 18 (12H) LSB

7

6

5

4

3

Reserved

Task Number

0=COM1 1=COM2

Word 1

MSB LSB

Reserved Number of Fields to Follow (1-11)

Word 2

Timeout Value (in 100 ms units, 0 = no timeout)

Word 3

Field 1: Length (number of bytes)

Word 4

Field 1: Start Address in RFID Tag

Word 5

Field 2: Length (number of bytes)

Word 6

Field 2: Start Address in RFID Tag

Word

Field n: Length (number of bytes)

(n x 2) + 1 Word

Field n: Start Address in RFID Tag

(n x 2) + 2 Word

Data bytes to write, where “F” is the field number (118 bytes max.)

(F x 2) + 3

When the command BTW is complete, set the Initiate bit in the output file.

64