Page 111
A APPENDIX QUICK REFERENCE Command
Opcode Decimal
Binary
Description
Page
Hex
Tag Fill
4
0000 0100
04
Fill tag with repeating byte 38
Tag Read
5
0000 0101
05
Read tag at RFID port
40
Tag Write
6
0000 0110
06
Write to tag at RFID port
43
Serial ReadLn (RS232)
9
0000 1001
09
Read serial data until
49 termination character Define Serial Parameters
10
0000 1010
0A
Sets serial interfaces
36
Serial Read (RS232)
11
0000 1011
0B
Read data from serial port
52
Serial Write (RS232)
12
0000 1100
0C
Write data to serial port
54
Reset Tag Battery Timer
13
0000 1101
0D
Battery time byte on tag
45
Clear Serial Buffers
14
0000 1110
0E is cleared Clears input/output serial
56 buffers HMS Tag Fill (RS232)
16
0001 0000
10
Fills tags with repeated
58 byte HMS Tag Read (RS232)
17
0001 0001
11
Read HMS tag at RFID
60 port HMS Tag Write (RS232)
18
0001 0010
12
Write to tag at RFID port
63
Tag-to-Tag Transfer
20
0001 0100
14
Copies data from one tag
47 to another Serial Read (MUX32)
30
0001 1110
1E
Read data from MUX32
65 slave Serial Write (MUX32)
31
0001 1111
1F
Write data to MUX32
67 slave HMS Tag Read (MUX32)
32
0010 0000
20
Read data to HMS tag via
71
MUX32 slave HMS Tag Write (MUX32)
33
0010 0001
21
Write data to HMS tag
73 via MUX32 slave HMS Tag Fill (MUX32)
34
0010 0010
22
Fills HMS tag with
75 repeated byte via MUX32 slave Collect (MUX32)
39
0010 0111
27
Retrieves data from 30-
69
Series commands Read, Auto-polled (MUX32)
40
0010 1000
28
Polls MUX32 Bus, returns
88 data, status, and address of responding slave Write, Auto-polled (MUX32)
41
0010 1001
29
Writes data to specified
91
MUX32 slave
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
105
Page 112
Command
Tag Read, Auto-polled
Opcode Decimal
Binary
Hex
42
0010 1010
2A
(HMS MUX32) Tag Writ, Auto-polled
Page
Reads data from HMS
83
Tag at specified Antenna 43
0010 1011
2B
(HMS MUX32) Tag Fill,Auto-polled
Description
Writes data to HMS Tag
85 at specified Antenna 44
0010 1100
2C
(HMS MUX32)
Writes Fill Byte to
87 addresses in HMS Tag at specified Antenna
Post Tag Read
60
0011 1100
3C
Tag read is posted
91
Post Tag Write
61
0011 1101
3D
Tag write is posted
93
Post Serial Read
62
0011 1110
3E
Serial read is posted
95
Post Serial ReadLn
63
0011 1111
3F
Serial ReadLn is Posted
97
Buffer Read
68
0100 0100
44
Reads data from Task
99
Buffer following posted command Buffer Write
69
0100 0101
45
Write data to Task Buffer
102 preceding a posted write command Define Mode
120
0111 1000
78
Establishes global
32 parameters
106
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
Page 113
B APPENDIX SPECIFICATIONS
Electrical Supply Voltage
24 VDC (+/-15%)
Current Consumption
350 mA (module only) 900 mA (with antennas)
Communication Compatibility
Remote I/O
RFID Interface
Two HS/HL-Series antenna ports
COM1
RS232
COM2
RS232/RS422/RS485 (MUX32)
Inputs - CM52
Two industrial-level inputs, 10-30 Vdc
HMS-Series through serial ports
Output - CM52
Two industrial-level output, 5-30 Vdc (400 mA, sinking)
Mechanical Specifications Dimensions (L x W x H)
2.00 x 7.50 x
6.00 inches
(51 x 191x 152 cm) Weight
2.0 lb. (0.9 kg)
Enclosure
EMI shielded ABS shell
Environmental Operating Temperature
+32 to 122 degrees F (0 to 50 degrees C)
Storage Temperature
-4 to 158 degrees F (-20 to 70 degrees C)
Humidity
90% non-condensing
Shock Resistance
IEC 68-2-27 test EA 30g; 11 msec; 3 shocks each axis
Vibration Resistance
IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours each axis
Protection Class
NEMA 2 (IP31)
NOTE:Specifications are subject to change without notice.
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
107
Page 114
C APPENDIX ASCII CHART Decimal
Hex
Character
Decimal
Hex
Character
000
00
NUL
030
1E
RS
001
01
SOH
031
1F
US
002
02
STX
032
20
(space)
003
03
ETX
033
21
!
004
04
EOT
034
22
‘’
005
05
ENQ
035
23
#
006
06
ACK
036
24
$
007
07
BEL
037
25
%
008
08
BS
038
26
&
009
09
HT
039
27
`
010
0A
LF
040
28
(
011
0B
VT
041
29
)
012
0C
FF
042
2A
*
013
0D
CR
043
2B
+
014
0E
SO
044
2C
‘
015
0F
SI
045
2D
-
016
10
DLE
046
2E
.
017
11
DC1
047
2F
/
018
12
DC2
048
30
0
019
13
DC3
049
31
1
020
14
DC4
050
32
2
021
15
NAK
051
33
3
022
16
SYN
052
34
4
023
17
ETB
053
35
5
024
18
CAN
054
36
6
025
19
EM
055
37
7
026
1A
SUB
056
38
8
027
1B
ESC
057
39
9
028
1C
FS
058
3A
:
029
1D
GS
059
3B
;
108
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
Page 115
Decimal
Hex
Character
Decimal
Hex
Character
060
3C
<
094
5E
^
061
3D
=
095
5F, 062
3E
>
096
60
`
063
3F
?
097
61 a
064
40
@
098
62 b
065
41
A
099
63 c
066
42
B
100
64 d
067
43
C
101
65 e
068
44
D
102
66 f
069
45
E
103
67 g
070
46
F
104
68 h
071
47
G
105
69 i
072
48
H
106
6A j
073
49
I
107
6B k
074
4A
J
108
6C l
075
4B
K
109
6D m
076
4C
L
110
6E n
077
4D
M
111
6F o
078
4E
N
112
70 p
079
4F
O
113
71 q
080
50
P
114
72 r
081
51
Q
115
73 s
082
52
R
116
74 t
083
53
S
117
75 u
084
54
T
118
76 v
085
55
U
119
77 w
086
56
V
120
78 x
087
57
W
121
79 y
088
58
X
122
7A z
089
59
Y
123
7B
{
090
5A
Z
124
7C
|
091
5B
[
125
7D
}
092
5C
\
126
7E
~
093
5D
]
127
7F
DEL
Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module
109
Page 116
Notes:
110