Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 12

CM52 Remote I/O Interface Module Operator's Manual, pages 111 to 116

Pages 111 to 116 of 116

The original document is the PDF (886 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic CM52

Page 111

A APPENDIX QUICK REFERENCE Command

Opcode Decimal

Binary

Description

Page

Hex

Tag Fill

4

0000 0100

04

Fill tag with repeating byte 38

Tag Read

5

0000 0101

05

Read tag at RFID port

40

Tag Write

6

0000 0110

06

Write to tag at RFID port

43

Serial ReadLn (RS232)

9

0000 1001

09

Read serial data until

49 termination character Define Serial Parameters

10

0000 1010

0A

Sets serial interfaces

36

Serial Read (RS232)

11

0000 1011

0B

Read data from serial port

52

Serial Write (RS232)

12

0000 1100

0C

Write data to serial port

54

Reset Tag Battery Timer

13

0000 1101

0D

Battery time byte on tag

45

Clear Serial Buffers

14

0000 1110

0E is cleared Clears input/output serial

56 buffers HMS Tag Fill (RS232)

16

0001 0000

10

Fills tags with repeated

58 byte HMS Tag Read (RS232)

17

0001 0001

11

Read HMS tag at RFID

60 port HMS Tag Write (RS232)

18

0001 0010

12

Write to tag at RFID port

63

Tag-to-Tag Transfer

20

0001 0100

14

Copies data from one tag

47 to another Serial Read (MUX32)

30

0001 1110

1E

Read data from MUX32

65 slave Serial Write (MUX32)

31

0001 1111

1F

Write data to MUX32

67 slave HMS Tag Read (MUX32)

32

0010 0000

20

Read data to HMS tag via

71

MUX32 slave HMS Tag Write (MUX32)

33

0010 0001

21

Write data to HMS tag

73 via MUX32 slave HMS Tag Fill (MUX32)

34

0010 0010

22

Fills HMS tag with

75 repeated byte via MUX32 slave Collect (MUX32)

39

0010 0111

27

Retrieves data from 30-

69

Series commands Read, Auto-polled (MUX32)

40

0010 1000

28

Polls MUX32 Bus, returns

88 data, status, and address of responding slave Write, Auto-polled (MUX32)

41

0010 1001

29

Writes data to specified

91

MUX32 slave

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

105

Page 112

Command

Tag Read, Auto-polled

Opcode Decimal

Binary

Hex

42

0010 1010

2A

(HMS MUX32) Tag Writ, Auto-polled

Page

Reads data from HMS

83

Tag at specified Antenna 43

0010 1011

2B

(HMS MUX32) Tag Fill,Auto-polled

Description

Writes data to HMS Tag

85 at specified Antenna 44

0010 1100

2C

(HMS MUX32)

Writes Fill Byte to

87 addresses in HMS Tag at specified Antenna

Post Tag Read

60

0011 1100

3C

Tag read is posted

91

Post Tag Write

61

0011 1101

3D

Tag write is posted

93

Post Serial Read

62

0011 1110

3E

Serial read is posted

95

Post Serial ReadLn

63

0011 1111

3F

Serial ReadLn is Posted

97

Buffer Read

68

0100 0100

44

Reads data from Task

99

Buffer following posted command Buffer Write

69

0100 0101

45

Write data to Task Buffer

102 preceding a posted write command Define Mode

120

0111 1000

78

Establishes global

32 parameters

106

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 113

B APPENDIX SPECIFICATIONS

Electrical Supply Voltage

24 VDC (+/-15%)

Current Consumption

350 mA (module only) 900 mA (with antennas)

Communication Compatibility

Remote I/O

RFID Interface

Two HS/HL-Series antenna ports

COM1

RS232

COM2

RS232/RS422/RS485 (MUX32)

Inputs - CM52

Two industrial-level inputs, 10-30 Vdc

HMS-Series through serial ports

Output - CM52

Two industrial-level output, 5-30 Vdc (400 mA, sinking)

Mechanical Specifications Dimensions (L x W x H)

2.00 x 7.50 x

6.00 inches

(51 x 191x 152 cm) Weight

2.0 lb. (0.9 kg)

Enclosure

EMI shielded ABS shell

Environmental Operating Temperature

+32 to 122 degrees F (0 to 50 degrees C)

Storage Temperature

-4 to 158 degrees F (-20 to 70 degrees C)

Humidity

90% non-condensing

Shock Resistance

IEC 68-2-27 test EA 30g; 11 msec; 3 shocks each axis

Vibration Resistance

IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours each axis

Protection Class

NEMA 2 (IP31)

NOTE:Specifications are subject to change without notice.

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

107

Page 114

C APPENDIX ASCII CHART Decimal

Hex

Character

Decimal

Hex

Character

000

00

NUL

030

1E

RS

001

01

SOH

031

1F

US

002

02

STX

032

20

(space)

003

03

ETX

033

21

!

004

04

EOT

034

22

‘’

005

05

ENQ

035

23

#

006

06

ACK

036

24

$

007

07

BEL

037

25

%

008

08

BS

038

26

&

009

09

HT

039

27

`

010

0A

LF

040

28

(

011

0B

VT

041

29

)

012

0C

FF

042

2A

*

013

0D

CR

043

2B

+

014

0E

SO

044

2C

‘

015

0F

SI

045

2D

-

016

10

DLE

046

2E

.

017

11

DC1

047

2F

/

018

12

DC2

048

30

0

019

13

DC3

049

31

1

020

14

DC4

050

32

2

021

15

NAK

051

33

3

022

16

SYN

052

34

4

023

17

ETB

053

35

5

024

18

CAN

054

36

6

025

19

EM

055

37

7

026

1A

SUB

056

38

8

027

1B

ESC

057

39

9

028

1C

FS

058

3A

:

029

1D

GS

059

3B

;

108

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

Page 115

Decimal

Hex

Character

Decimal

Hex

Character

060

3C

<

094

5E

^

061

3D

=

095

5F, 062

3E

>

096

60

`

063

3F

?

097

61 a

064

40

@

098

62 b

065

41

A

099

63 c

066

42

B

100

64 d

067

43

C

101

65 e

068

44

D

102

66 f

069

45

E

103

67 g

070

46

F

104

68 h

071

47

G

105

69 i

072

48

H

106

6A j

073

49

I

107

6B k

074

4A

J

108

6C l

075

4B

K

109

6D m

076

4C

L

110

6E n

077

4D

M

111

6F o

078

4E

N

112

70 p

079

4F

O

113

71 q

080

50

P

114

72 r

081

51

Q

115

73 s

082

52

R

116

74 t

083

53

S

117

75 u

084

54

T

118

76 v

085

55

U

119

77 w

086

56

V

120

78 x

087

57

W

121

79 y

088

58

X

122

7A z

089

59

Y

123

7B

{

090

5A

Z

124

7C

|

091

5B

[

125

7D

}

092

5C

\

126

7E

~

093

5D

]

127

7F

DEL

Copyright 1998, Escort Memory Systems CM52 Remote I/O Interface Module

109

Page 116

Notes:

110