Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Datalogic CM52 Spec Sheet

Spec sheet · Datalogic

Datalogic CM52 Spec Sheet

Spec sheet4 pagesPDF 208 KB

All 4 pages are below, each with its text.

Download the PDF208 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Spec sheet from EMS, a Datalogic Group company, for the CM52 Remote I/O Module, a programmable interface between the Allen-Bradley Remote I/O network and RFID antennas, RFID reader/writers or bar code scanners. It lists features, electrical, communication, mechanical and environment specifications, connections and accessories.

Device
Programmable interface between the Allen-Bradley Remote I/O network and RFID antennas, reader/writers or bar code scanners p. 1
RFID connections
Up to two HS/HL500-Series antennas, or as many as 32 HMS-Series reader/writers, RS-Series readers or bar code scanners on a Mux32 line p. 1
Power
24VDC ±15% from an external connector; 350mA module only, 900mA with antennas p. 2
Processor and memory
25 MHz i386 processor, 512KB flash memory, 512KB RAM, DOS compatible operating system p. 1
Serial ports
Two general purpose serial ports: RS232, and RS232/RS422/RS485 (Mux32 Protocol) p. 1, 2
Inputs and outputs
Two industrial-level inputs, 10-30VDC; two industrial-level outputs, 5-30VDC@400mA, sourcing or sinking p. 2
Size and weight
7.5 x 6.0 x 2.1in. (191 x 152 x 51mm), W x H x D; 2.0lbs. (0.9kg); ABS shell p. 2
Enclosure rating
NEMA 2 (IP31) p. 1, 4
Environment
90% non-condensing humidity; shock IEC 68-2-27 Test EA 30g; vibration IEC 68-2-6 Test FC 1.5mm, 10-55Hz p. 2
Tags
HS200R, HS200XL or HS200LR-Series tags with HS500 antennas; ES600-Series read only tags with RS400-Series readers; HMS100-Series tags with HMS-Series reader/writers p. 4
Standard program
Remote I/O commands control block reads and writes, Mux32 status, serial I/O and tag fill; up to four commands at once p. 1
Debug port
Software upgrade port, or RS232 serial device connection (HMS800-Series, RS400-Series) p. 4
Construction
Two board set joined by a stackable PC104 connector p. 1
Accessories
DIN rail clips with screws; mating connector for the Remote I/O bus p. 4

What this sheet walks you through

  • What the standard program lets Remote I/O commands do p. 1
  • Electrical, communication, mechanical and environment specifications p. 2
  • Connecting antennas, reader/writers and serial devices p. 4

Good to know

  • One serial port serves at most 32 reader/writers or other serial devices. p. 4

Questions this sheet answers

What does the Datalogic CM52 do?

It links the Allen-Bradley Remote I/O network to RFID antennas, RFID reader/writers or bar code scanners, so a PLC can read and write tags. p. 1

What power does the CM52 need?

24VDC ±15% from an external connector: 350mA for the module alone, 900mA with antennas. p. 2

How many readers can connect to one CM52?

Up to two HS/HL500-Series antennas, or as many as 32 HMS-Series reader/writers, RS-Series readers or bar code scanners on a Mux32 line. p. 1

Which RFID tags work with the CM52?

HS200R, HS200XL or HS200LR-Series tags with HS500 antennas, ES600-Series read only tags with RS400-Series readers, and HMS100-Series tags with HMS-Series reader/writers. p. 4

The file

Size and text

Pages4
PDF208 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Datalogic CM52 Spec Sheet

The text of page 1, from the PDF itself

CM52

CM52 Remote I/O Module Features

  • Two Read/Write RFID Antenna Ports
  • 25 MHz i386 Processor
  • 512KB Flash Memory
  • 512KB RAM
  • DOS Compatible Operating System
  • Two General Purpose Serial Ports for CM52
  • Two Industrial-Level Inputs/Outputs
  • LED Status Indicators
  • NEMA 2 (IP31) Enclosure

Applications

  • Material Handling
  • Sortation Systems
  • Work-in-Progress Monitoring
  • Quality Control

Use With

EMS Passive Read/Write EMS Passive Read Only EMS Active Read/Write RS232 and RS422 Serial Devices

a Datalogic Group Company, is the field-proven leader in the development and application of Radio Frequency Identification (RFID) Tags/Labels/PCBs, Antennas, Controllers and network interface modules for tough industrial environments. With over a dozen years of RFID successes in the automotive, electronics, material handling and food processing industries, EMS has built a global reputation in providing customers with complete supply chain solutions – from production to retail EMS has the complete solution!

EMS,

Technical Description The CM52 is a general purpose programmable interface between the Allen-Bradley Remote I/O network and up to two HS/HL500-Series Antennas, or as many as 32 HMS-Series Reader/Writers, RS-Series Readers, or bar code scanners (or a combination of both) on a Mux32 line. The CM52 can be used to give a Remote I/O presence to a wide range of existing equipment, such as bar code Readers, RFID Controllers, bar code verifiers, sensors and switches.

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

This programmable interface is provided with a standard program that allows Remote I/O commands to control the reading and EMOTE writing of a block (or non-contiguous RESENCE blocks) of data, FOR Mux32 connection status, serial inputs/ UTO outputs, and Tag fill functions.

R PI/OA ID PRODUCTS

The standard program can readily be modified by EMS. For special applications; contact your EMS representative. The module is based on a real-time, DOS compatible operating system providing great speed and flexibility. As many as four commands can be processed simultaneously. The CM52 is implemented as a two board set, interconnected by a stackable PC104 Connector.

Fax: 831/438-5768Web: www.ems-rfid.com177

Page 2 of Datalogic CM52 Spec Sheet

The text of page 2, from the PDF itself

CM52 Remote I/O Module Electrical

Power Requirements From External Connector

24VDC ±15% 350mA (Module Only) 900mA (with Antennas)

Communication

Interface RFID

A-B Remote I/O Two EMS HS/HL-Series Antenna Ports, HMS-Series Readers through Serial Ports

Ports

COM1 COM2 Input Output

RS232 RS232/RS422/RS485(Mux32 Protocol) Two Industrial-Level Inputs, 10-30VDC Two Industrial-Level Outputs, 5-30VDC@400mA Either Sourcing or Sinking

Mechanical Specifications

Dimensions (W x H x D) Weight Enclosure

7.5 x 6.0 x 2.1in. (191 x 152 x 51mm) 2.0lbs. (0.9kg) ABS Shell

Environment

Operating Temperature Storage Temperature Humidity Shock Resistance Vibration Resistance

32º to 120ºF (0º to 49ºC) -4º to 158ºF (-20º to 70ºC) 90% Non-Condensing IEC 68-2-27 Test EA 30g; 11ms; 3 Shocks Each Axis IEC 68-2-6 Test FC 1.5mm; 10-55Hz; 2 Hours Each Axis NEMA 2 (IP31)

Protection Class

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

178Fax: 831/438-5768Web: www.ems-rfid.com

Page 3 of Datalogic CM52 Spec Sheet

The text of page 3, from the PDF itself

CM52 Remote I/O Module Mechanical Dimensions

POWER

Remote I/O Module

CM52 BUS ACTIVE ANT 0 ANT 1 COMM 1 COMM 2

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

Fax: 831/438-5768Web: www.ems-rfid.com179

Page 4 of Datalogic CM52 Spec Sheet

The text of page 4, from the PDF itself

CM52 Remote I/O Module Connections Remote I/O Bus Two Read/Write Ports Connect to HS500-Series Antennas Use any HS200R, HS200XL or HS200LR-Series Tags

Read/Write AntennaHS500Read/Write AntennaCOMM 2COMM 1ANT 1ANT 0BUS ACTIVEPOWERCM52HS500Remote I/O ModuleCM52 Remote I/O Module

One Serial Port for Connection to as many as 32 Readers/Writers or other Serial Devices. Connect to RS400-Series Readers with ES600-Series Read Only Tags. Connect to HMS-Series Reader/Writers with HMS100-Series Read/Write Tags.

Passive Reader/Writer

HMS827

Software Upgrade Port (Debug Port) or RS232 Serial Device Connection (HMS800-Series, RS400-Series)

Available Models ModelDescriptionCM52

Remote I/O Module, NEMA 2 (IP31)

Accessories ModelDescription00-1096 30-1022

DIN Rail Clips with Screws Mating Connector Remote I/O Bus

Your Complete Supply Chain RFID Provider – Call: 831/438-7000

180Fax: 831/438-5768Web: www.ems-rfid.com

More documents · 1

For the same models