Spec sheet from EMS, a Datalogic Group company, for the CM52 Remote I/O Module, a programmable interface between the Allen-Bradley Remote I/O network and RFID antennas, RFID reader/writers or bar code scanners. It lists features, electrical, communication, mechanical and environment specifications, connections and accessories.
- Device
- Programmable interface between the Allen-Bradley Remote I/O network and RFID antennas, reader/writers or bar code scanners p. 1
- RFID connections
- Up to two HS/HL500-Series antennas, or as many as 32 HMS-Series reader/writers, RS-Series readers or bar code scanners on a Mux32 line p. 1
- Power
- 24VDC ±15% from an external connector; 350mA module only, 900mA with antennas p. 2
- Processor and memory
- 25 MHz i386 processor, 512KB flash memory, 512KB RAM, DOS compatible operating system p. 1
- Serial ports
- Two general purpose serial ports: RS232, and RS232/RS422/RS485 (Mux32 Protocol) p. 1, 2
- Inputs and outputs
- Two industrial-level inputs, 10-30VDC; two industrial-level outputs, 5-30VDC@400mA, sourcing or sinking p. 2
- Size and weight
- 7.5 x 6.0 x 2.1in. (191 x 152 x 51mm), W x H x D; 2.0lbs. (0.9kg); ABS shell p. 2
- Enclosure rating
- NEMA 2 (IP31) p. 1, 4
- Environment
- 90% non-condensing humidity; shock IEC 68-2-27 Test EA 30g; vibration IEC 68-2-6 Test FC 1.5mm, 10-55Hz p. 2
- Tags
- HS200R, HS200XL or HS200LR-Series tags with HS500 antennas; ES600-Series read only tags with RS400-Series readers; HMS100-Series tags with HMS-Series reader/writers p. 4
- Standard program
- Remote I/O commands control block reads and writes, Mux32 status, serial I/O and tag fill; up to four commands at once p. 1
- Debug port
- Software upgrade port, or RS232 serial device connection (HMS800-Series, RS400-Series) p. 4
- Construction
- Two board set joined by a stackable PC104 connector p. 1
- Accessories
- DIN rail clips with screws; mating connector for the Remote I/O bus p. 4
What this sheet walks you through
- What the standard program lets Remote I/O commands do p. 1
- Electrical, communication, mechanical and environment specifications p. 2
- Connecting antennas, reader/writers and serial devices p. 4
Good to know
- One serial port serves at most 32 reader/writers or other serial devices. p. 4
Questions this sheet answers
What does the Datalogic CM52 do?
It links the Allen-Bradley Remote I/O network to RFID antennas, RFID reader/writers or bar code scanners, so a PLC can read and write tags. p. 1
What power does the CM52 need?
24VDC ±15% from an external connector: 350mA for the module alone, 900mA with antennas. p. 2
How many readers can connect to one CM52?
Up to two HS/HL500-Series antennas, or as many as 32 HMS-Series reader/writers, RS-Series readers or bar code scanners on a Mux32 line. p. 1
Which RFID tags work with the CM52?
HS200R, HS200XL or HS200LR-Series tags with HS500 antennas, ES600-Series read only tags with RS400-Series readers, and HMS100-Series tags with HMS-Series reader/writers. p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
CM52
CM52 Remote I/O Module Features
- Two Read/Write RFID Antenna Ports
- 25 MHz i386 Processor
- 512KB Flash Memory
- 512KB RAM
- DOS Compatible Operating System
- Two General Purpose Serial Ports for CM52
- Two Industrial-Level Inputs/Outputs
- LED Status Indicators
- NEMA 2 (IP31) Enclosure
Applications
- Material Handling
- Sortation Systems
- Work-in-Progress Monitoring
- Quality Control
Use With
EMS Passive Read/Write EMS Passive Read Only EMS Active Read/Write RS232 and RS422 Serial Devices
a Datalogic Group Company, is the field-proven leader in the development and application of Radio Frequency Identification (RFID) Tags/Labels/PCBs, Antennas, Controllers and network interface modules for tough industrial environments. With over a dozen years of RFID successes in the automotive, electronics, material handling and food processing industries, EMS has built a global reputation in providing customers with complete supply chain solutions – from production to retail EMS has the complete solution!
EMS,
Technical Description The CM52 is a general purpose programmable interface between the Allen-Bradley Remote I/O network and up to two HS/HL500-Series Antennas, or as many as 32 HMS-Series Reader/Writers, RS-Series Readers, or bar code scanners (or a combination of both) on a Mux32 line. The CM52 can be used to give a Remote I/O presence to a wide range of existing equipment, such as bar code Readers, RFID Controllers, bar code verifiers, sensors and switches.
Your Complete Supply Chain RFID Provider – Call: 831/438-7000
This programmable interface is provided with a standard program that allows Remote I/O commands to control the reading and EMOTE writing of a block (or non-contiguous RESENCE blocks) of data, FOR Mux32 connection status, serial inputs/ UTO outputs, and Tag fill functions.
R PI/OA ID PRODUCTS
The standard program can readily be modified by EMS. For special applications; contact your EMS representative. The module is based on a real-time, DOS compatible operating system providing great speed and flexibility. As many as four commands can be processed simultaneously. The CM52 is implemented as a two board set, interconnected by a stackable PC104 Connector.
Fax: 831/438-5768Web: www.ems-rfid.com177
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
CM52 Remote I/O Module Electrical
Power Requirements From External Connector
24VDC ±15% 350mA (Module Only) 900mA (with Antennas)
Communication
Interface RFID
A-B Remote I/O Two EMS HS/HL-Series Antenna Ports, HMS-Series Readers through Serial Ports
Ports
COM1 COM2 Input Output
RS232 RS232/RS422/RS485(Mux32 Protocol) Two Industrial-Level Inputs, 10-30VDC Two Industrial-Level Outputs, 5-30VDC@400mA Either Sourcing or Sinking
Mechanical Specifications
Dimensions (W x H x D) Weight Enclosure
7.5 x 6.0 x 2.1in. (191 x 152 x 51mm) 2.0lbs. (0.9kg) ABS Shell
Environment
Operating Temperature Storage Temperature Humidity Shock Resistance Vibration Resistance
32º to 120ºF (0º to 49ºC) -4º to 158ºF (-20º to 70ºC) 90% Non-Condensing IEC 68-2-27 Test EA 30g; 11ms; 3 Shocks Each Axis IEC 68-2-6 Test FC 1.5mm; 10-55Hz; 2 Hours Each Axis NEMA 2 (IP31)
Protection Class
Your Complete Supply Chain RFID Provider – Call: 831/438-7000
178Fax: 831/438-5768Web: www.ems-rfid.com
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
CM52 Remote I/O Module Mechanical Dimensions
POWER
Remote I/O Module
CM52 BUS ACTIVE ANT 0 ANT 1 COMM 1 COMM 2
Your Complete Supply Chain RFID Provider – Call: 831/438-7000
Fax: 831/438-5768Web: www.ems-rfid.com179
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
CM52 Remote I/O Module Connections Remote I/O Bus Two Read/Write Ports Connect to HS500-Series Antennas Use any HS200R, HS200XL or HS200LR-Series Tags
Read/Write AntennaHS500Read/Write AntennaCOMM 2COMM 1ANT 1ANT 0BUS ACTIVEPOWERCM52HS500Remote I/O ModuleCM52 Remote I/O Module
One Serial Port for Connection to as many as 32 Readers/Writers or other Serial Devices. Connect to RS400-Series Readers with ES600-Series Read Only Tags. Connect to HMS-Series Reader/Writers with HMS100-Series Read/Write Tags.
Passive Reader/Writer
HMS827
Software Upgrade Port (Debug Port) or RS232 Serial Device Connection (HMS800-Series, RS400-Series)
Available Models ModelDescriptionCM52
Remote I/O Module, NEMA 2 (IP31)
Accessories ModelDescription00-1096 30-1022
DIN Rail Clips with Screws Mating Connector Remote I/O Bus
Your Complete Supply Chain RFID Provider – Call: 831/438-7000