Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

C-BOX 200 Installation Manual, pages 11 to 20

Pages 11 to 20 of 28

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic C-Box 200

Page 11

C-BOX 200

DATALOGIC

2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the C-BOX 200 and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: 1)

C-BOX 200

2)

Installation manual

2

1

Figure 2.1 - C-BOX 200 package contents

2 - Installation

Page 12

DATALOGIC

C-BOX 200

2.2 OPENING THE DEVICE To install the C-BOX 200 or during normal maintenance, it is necessary to open it by unscrewing the four cover screws:

WARNING The C-BOX 200 must be disconnected from the power supply during this operation.

Figure 2.2 - Opening the C-BOX 200

It is possible to perform the following operations: •

Proceed with the cable connections (see paragraph 2.4.2).

•

Set the multiplexer address selection on the rotary switches.

•

Mount the C-BOX 200 to a wall or panel.

Installation - 3

Page 13

C-BOX 200

DATALOGIC

2.3 MECHANICAL INSTALLATION The diagram below gives the overall dimensions of the C-BOX 200 and may be used for its installation. ∅ ∅ mm in

Figure 2.3 - Overall dimensions

4 - Installation

Page 14

DATALOGIC

C-BOX 200

C-BOX 200 can be installed to operate in different positions. The two screw holes inside the housing of the C-BOX 200 are for mechanical fixture (Figure 2.4). To mount the C-BOX 200: 1) Open the C-BOX 200 by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the device as a pattern, mark the panel with an appropriate object and then drill two holes in the panel. 2) Align the C-BOX 200 and insert two screws and screw them into the panel until tight (see Figure 2.4).

Figure 2.4 - Mounting C-BOX 200

Installation - 5

Page 15

C-BOX 200

DATALOGIC

2.4 ELECTRICAL CONNECTIONS AND SETUP The following figure shows the typical layout. The dotted line in the figure refers to an optional hardware configuration.

PC Scanner Auxiliary Interface SCANNER

System Cables Figure 2.5 – System layout

A PC can be quickly connected to the C-BOX 200 (and consequently to the scanner auxiliary interface) through the internal 9-pin connector. This allows monitoring of the data transmitted by the scanner or configuration through the WinHost utility (see the scanner Installation Manual for more details). The scanner auxiliary interface signals are also available on the internal spring clamp connectors. After making system cabling and switch settings (see sub-paragraphs under 2.4), connect the scanner to the 25-pin connector on the left side of the CBOX 200 housing. Switch ON the C-BOX 200 power switch (see Figure 2.6). After power on, an automatic connection procedure takes place between the C-BOX 200 and the scanner. During this phase, requiring a few seconds, the warning LED is turned ON. Once the procedure had been completed successfully, the warning LED is turned OFF. After system functioning has been verified, close the C-BOX 200 using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing. 6 - Installation

Page 16

DATALOGIC

C-BOX 200

2.4.1 Power Supply Power is supplied to the C-BOX 200 through the pins provided on the spring clamp connector. The power switch (see Figure 2.6) switches the power supply ON or OFF for both the C-BOX 200 and the connected scanner.

ON S1 OFF

Figure 2.6 - Power switch ON/OFF positions

USER INTERFACE

C-BOX 1

VS

2

GND

V+ (10 - 30 Vdc) GND

Figure 2.7 - Power supply connections

NOTE Pin 1 is also electrically connected to pins 3 and 5, just as pin 2 is electrically connected to pins 4 and 6. This is useful for external trigger/inputs connections. The power supply must be between 10 and 30 Vdc only.

Installation - 7

Page 17

C-BOX 200

DATALOGIC

2.4.2 System Wiring The connection and wiring procedure for C-BOX 200 is described as follows: 1)

Open the C-BOX 200 as described in paragraph 2.2.

2)

Verify that the C-BOX 200 power switch is off (see Figure 2.6).

3)

Unscrew the compression connectors and pass all the system cables through them into the C-BOX 200 housing.

4)

To connect the power and input/output signals: •

Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm.

•

Using a device such as a screwdriver, push down on the lever directly next to the clamp (see Figure 2.8).

•

Insert the wire into the clamp and release the lever.

The wire will now be held in the spring clamp.

Figure 2.8 - System cable connections

The wiring used can be solid or stranded but must meet the following specifications. All positions:

8 - Installation

24 - 16 AWG

0.2 - 1.5 mm²

Page 18

DATALOGIC

C-BOX 200

The C-BOX 200 spring clamp connector pinouts are indicated in the following table. Refer to the scanner Installation Manual for details. Pin 1, 3, 5 2, 4, 6 7, 8 *9, 13 *10, 14 *11, 15 *12, 16 20, 33, 34, 40 21 23 27 28 35 37 39

22 24 25, 26 29 30 31 32 36 38

Name VS GND EARTH GROUND RS485 CABLE SHIELD RS485 REF RTX485+ RTX485Reserved OUT1+ OUT2+ EXT TRIG+ EXT TRIGTXA RXA SGND DS2100 DS2400 OUT REF OUT REF NC NC NC NC NC RTSA CTSA

DS4300 DS4600 OUT1OUT2Reserved IN1+ IN1IN2+ IN2GND SGND AUX

*The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In this way the network bus can enter and exit the C-BOX from different spring clamps but be physically connected together.

NOTE Pin 7 or 8 should be connected to the earth ground. Pin 17, 18 and 19 are not present in the C-BOX 200 model.

Installation - 9

Page 19

C-BOX 200

DATALOGIC

2.4.3 Chassis Grounding Jumper Settings The scanner chassis grounding method can be selected by positioning a jumper (see Figure 2.9). In this way the scanner chassis can be connected to earth ground (only if pins 7 or 8 are connected to a good earth ground) or to the power supply ground signal. The scanner chassis can also be left floating but, in this case, the jumper must be removed.

to EARTH GROUND (default)

to GND floating

Figure 2.9 – Chassis grounding

The C-BOX 200 is now installed which completes the electrical connections for your scanning system.

10 - Installation

Page 20

DATALOGIC

C-BOX 200

2.4.4 Multidrop Address Selection For RS485 half-duplex interface connections, the scanner multidrop address should be set using the rotary switches placed inside the C-BOX 200. The valid address range is from 00 to 31. This value is read only at poweron; any change at run-time has no effect. If an invalid value is detected (32-99) the C-BOX cannot communicate with the Multiplexer and the green LED remains off. Furthermore, the SEND command configures the scanner using the previously configured valid scanner address.

TENS

UNITS

Figure 2.10 - Rotary switches

Installation - 11