The text of a manual · part 1 of 3
C-BOX 200 Installation Manual, pages 1 to 10
Pages 1 to 10 of 28
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic C-Box 200
Page 1
an €-fOx 200
Installation Manual
DATALOGIC] BEL
Bar Code & More
Page 2
C-BOX 200 INSTALLATION MANUAL
Page 3
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX 200, active connection box
01 e tutti i suoi modelli and all its models et tous ses modèles und seine modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y
92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022, August 1994:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)
EN 50082-2, March 1995:
ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT
Ruggero Cacioppo Lippo di Calderara, 07/03/2001 Quality Assurance Supervisor
Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies. Datalogic S.p.A. reserves the right to make modifications and improvements without prior notification. - 2001 Datalogic S.p.A.
821000560
Page 4
CONTENTS
GUIDE TO INSTALLATION.............................................................. iv SAFETY PRECAUTIONS .................................................................vii Power Supply ....................................................................................vii 1 1.1
GENERAL FEATURES...................................................................... 1 Description ......................................................................................... 1
2 2.1 2.2 2.3 2.4 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.4.6 2.4.7 2.5 2.6 2.7 2.7.1 2.7.2
INSTALLATION ................................................................................. 2 Package Contents .............................................................................. 2 Opening the Device............................................................................ 3 Mechanical Installation ....................................................................... 4 Electrical Connections and Setup ...................................................... 6 Power Supply ..................................................................................... 7 System Wiring .................................................................................... 8 Chassis Grounding Jumper Settings................................................ 10 Multidrop Address Selection............................................................. 11 RS485 Bus Termination ................................................................... 12 Connection to a Multiplexer .............................................................. 13 OM4000 Jumper Settings................................................................. 14 9-Pin Scanner Auxiliary Serial Interface ........................................... 15 Scanner Requirements..................................................................... 16 Operating Modes.............................................................................. 16 GET/SEND Buttons.......................................................................... 17 LED Indicators.................................................................................. 18
3
TECHNICAL FEATURES ................................................................ 19 iii
Page 5
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the C-BOX 200. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Correctly position and mount the C-BOX 200 within the reach of the barcode scanner cable, according to the information in paragraph 2.3. 3) Provide correct system cabling according to the signals necessary for your application and RS485 settings (see all sub-paragraphs under 2.4) The installation is now complete.
iv
Page 6
C-BOX 200 General View
3
1 2
Figure A
1 25-pin scanner connector 2 Compression connectors 3 Cover screws (4)
v
Page 7
C-BOX 200 General View
7
8
9
12
4 5 10
3 11
1
2
6 Figure B
1 Power switch (ON/OFF)
vi
2 Spring clamp terminal blocks
7 GET button 8 SEND button
3 Multidrop address switches
9 Auxiliary port connector
4 Power on LED
10 Chassis grounding selector
5 Warning LED
11 Termination resistance switch
6 Tx LED
12 OM4000 jumpers
Page 8
SAFETY PRECAUTIONS POWER SUPPLY ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT - This product is intended to be installed by Qualified Personnel only. The C-BOX 200 is intended to be supplied by an NEC Class 2 power source, rated 10-30 V, minimum 0.65 A. See par. 2.4.1 for correct power supply connections.
vii
Page 9
viii
Page 10
DATALOGIC
C-BOX 200
1 GENERAL FEATURES 1.1 DESCRIPTION The C-BOX 200 is a connection box which can be used as an accessory of the Datalogic scanners to perform the following functions: •
Facilitate the connection of the scanner signals using a spring clamp connector.
•
Perform a conversion from RS232 to RS485 multidrop system to connect a RS232 scanner to a multidrop network.
•
Optocoupled RS485 interface is used over long distances or in electrically noisy environments.
•
Get the scanner configuration and store it in memory.
•
Send the configuration stored in memory to the scanner.
The C-BOX 200 mechanical dimensions are 167 x 115 x 40 mm (6.57 x 4.53 x 1.57 in.). It weighs about 340 g. (12 oz). Electrical connection is provided through spring clamp terminal blocks inside the C-BOX 200. The scanner is connected to the C-BOX 200 through a 25-pin connector placed on the left side of the housing. A 9-pin connector placed inside the C-BOX 200 facilitates connection between an external PC and the auxiliary serial interface of the scanner.
General Features - 1