The text of a manual · part 5 of 6
C-BOX 150 Installation Manual, pages 21 to 28
Pages 21 to 28 of 34
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic C-Box 150
Page 21
INSTALLATION
2
The C-BOX 150 spring clamp connector pinouts are indicated in the following table. Refer to the scanner Reference Manual for details.
Scanner Pinouts Pin
Name
1, 3, 5 2, 4, 6 7, 8 *9, 13 20, 40 35 37
VS GND EARTH GROUND RS485 CABLE SHIELD RESERVED TX AUX RX AUX
21 22 23 24 25 26 27 28 29 30 31 32 33 34 36 38 39
DS2100A DS2400A
DS4600A
DS1100 DS2200
DS6X00 DX6X00 DS8100A DX8200A
OUT1+ OUT REF OUT2+ OUT REF NC NC EXT TRIG+ EXT TRIGNC NC NC NC RESERVED RESERVED RTSA CTSA SGND
OUT1+ OUT1OUT2+ OUT2RESERVED RESERVED EXT TRIG+ EXT TRIGIN1+ IN1IN2+ IN2RESERVED RESERVED GND SGND AUX SGND
OUT1+ IO REF OUT2+ IO REF NC IN1EXT TRIG+ EXT TRIGNC IO REF NC NC RESERVED RESERVED NC NC SGND
OUT1+ OUT1OUT2+ OUT2OUT 3A OUT 3B EXT TRIG/PS A EXT TRIG/PS B IN 2/ENC A IN 2/ENC B IN 3A IN 4A IN 3A IN 4A IN 3B/IN 4B GND GND
DS2100A DS2400A DS4600A DS6X00 DX6X00 DS8100A DX8200A RS232 RS485FD RS485HD 20mA CL (with INT-30 only)
*11, 15 *12, 16 17 18 *10, 14, 19
TX232 RTS232 RX232 CTS232 SGND MAIN
TX485+ TX485RX485+ RX485SGND MAIN
RTX485+ RTX485-
See INT-30 instructions
SGND MAIN
DS1100 DS2200 RS485HD *11, 15 *12, 16 17 18 *10, 14, 19
RTX485+ RTX485RESERVED RESERVED SGND MAIN
* The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In this way the network bus can enter and exit the C-Box 150 from different spring clamps but be physically connected together.
11
Page 22
C-BOX 150
2
2.4.3
Scanner Chassis Grounding Jumper Settings
The scanner chassis grounding method can be selected by positioning a jumper (see Figure 9). In this way the scanner chassis can be connected to earth ground (only if pins 7 or 8 are connected to a good earth ground) or to the power supply ground signal. The scanner chassis can also be left floating but, in this case, the jumper must be removed.
to EARTH GROUND (default)
to GND floating
Figure 9 – Chassis Grounding
2.4.4
Scanner Selection DS1100 DS2200
Other Devices Figure 10 - Scanner Selection Switch
This switch must be set upward only when a DS1100 or a DS2200 scanner (10-30 V version) is connected. For all the other devices the switch must be set downward.
12
Page 23
INSTALLATION
2.4.5
2
RS485 Bus Termination
ON
OFF Figure 11 - Termination Resistance Switch
This switch enables or disables the insertion of the bus termination resistor for RS485 Half Duplex Multidrop applications.
CAUTION
2.4.6
In Multiplexer applications the termination resistor must be enabled ONLY on the last device of the chain, the farthest away from the Multiplexer (assuming the Multiplexer is the first device of the chain). On all the other devices this resistor MUST NOT be enabled (OFF position).
Powering C-BOX 150 From A Scanner
In order for C-BOX 150 to accept power from the scanner through the 25-pin connector instead of the external power supply, a jumper can be positioned as indicated in Figure 12. This is useful, for example, in a typical Master Slaves layout with a Power Supply Unit connected to the scanners (see paragraph 2.6) or to pass power to connected accessories such as Encoder and Presence Sensor from DX8200A VAC models or other scanner layouts. See the relative scanner Reference Manual for details.
EXTERNAL PWR SUP. (default)
SCANNER PWR
Figure 12 – C-BOX 150 Power Source Jumper
13
Page 24
C-BOX 150
2
2.4.7
OM4000 Jumper Settings J5
J6
Figure 13 - OM4000 Jumpers
The jumpers allow connection to the EXT TRIG signals on separate spring clamp terminals for applications which use the OM4000 Oscillating Mirror in Trigger Mode. They are used together and they have the following significance: when a jumper is in the J5 position (see Figure above) pin 40 is connected to pin 27 (EXT TRIG+); a jumper in J6 position connects pin 20 to pin 28 (EXT TRIG-). If the jumpers are removed pin 20 and pin 40 are disconnected.
2.4.8
Configuration Switch And 9-Pin Internal Connector
The 9-pin internal connector may have two different functions according to the position of the configuration switch.
Figure 14 - Configuration Switch and 9-pin Male Connector
POSITION
MODE Normal Operation (default): In this position, the C-BOX 150 is in the normal operating mode. The configuration PC communicates with the scanner through the 9-pin internal connector and the scanner auxiliary serial interface. The internal connector pinout is illustrated in the following table:
14
Page 25
INSTALLATION
2 9-pin C-Box 150 connector pinout in Normal mode
Pin 1 2 3 4 5 6 7 8 9
Name RXA TXA GND RESERVED RESERVED
POSITION
Function NC Auxiliary RS232 Auxiliary RS232 NC Ground NC Device Dependent Signal Device Dependent Signal NC
MODE CFG: When the switch is in this position, the C-BOX 150 can be configured. The communication with the scanner is interrupted and pins 2 and 3 are no longer dedicated to the scanner auxiliary interface but to the C-BOX 150 configuration (see table below). The C-BOX 150 enters configuration mode and waits to be configured through WinHost (see WinHost Help On Line). Once the C-BOX 150 configuration is completed, it is necessary to return the switch in the Normal Operation position. At the end of the reboot phase, the C-BOX 150 is ready to function with the new configuration.
9-pin C-Box 150 connector pinout in Configuration mode Pin
Name
Function
2 3
RX TX
C-BOX 150 Configuration C-BOX 150 Configuration
5
SGND
Signal Ground
When the C-BOX 150 configuration is completed, remember to return the Configuration switch in the Normal Operation position. CAUTION
15
Page 26
C-BOX 150
2
2.5
OPERATING MODES
With the C-BOX 150, the following operating modes are possible: Normal Operation: At power on, the C-BOX 150 tries to connect to the scanner. Once the connection procedure is completed the C-BOX 150 verifies if an Automatic SEND command must be executed. While executing the command, the serial Auxiliary interface is not available for the user. After the command completion, the warning LED will turn OFF and the Aux interface will become free for communication. After the initialization procedure, in the Normal operating mode the scanner reads barcodes and communicates with the host. Also in this mode, through the C-BOX 150 internal buttons it is possible to communicate with the scanner to perform one of the three GET/TEST/SEND Functions (see paragraph 2.5.1). Configuration (CFG): When the CFG switch is in CFG position (left) it is possible to configure the C-BOX 150 parameters through WinHost.
2.5.1
GET/TEST/SEND Functions
The C-BOX 150 has three internal function buttons which are available in the Normal operating mode. C-BOX 150
GET
TEST
SEND
Figure 15 – Internal Function Buttons
The procedure to enable the GET/TEST/SEND function is the following: 1.
16
Press both the left and right buttons at the same time for at least one second; the warning LED will turn ON.
Page 27
INSTALLATION
2
2.
Release the buttons.
3.
Press the left button corresponding to the GET function, the center button corresponding to the TEST function or the right button corresponding to the SEND function.
NOTE
Once the buttons are released in step 1, a ten-second timeout starts. If no button is pressed within this time (no function is selected), the procedure will be cancelled. The C-Box 150 warning LED will turn OFF at the end of each procedure.
Function
Description
GET (left button)
The C-BOX 150 reads the current scanner configuration and permanently copies it in its own memory support. The C-BOX 150 preserves this configuration also when switched off. The GET option can be disabled through WinHost.
TEST (center button)
The C-BOX 150 forces the scanner (DS1100, DS2XXX families and DS4600A) to run the Test Operating Mode (refer to the scanner Reference Manual for details). Press any button to quit the Test Operating Mode and restore the scanner normal operating mode. For DS6XXX, DX6XXX, DS8100A and DX8200A scanners you should use scanner keypad.
SEND (right button)
The C-BOX 150 sends the configuration previously stored in its own permanent memory support to the scanner’s memory. The SEND option can be disabled through WinHost; by default it is Automatic.
To override the eventual default Automatic SEND service, it is possible to preset a GET service by executing the enabling procedure immediately at power-on. NOTE
17
Page 28
C-BOX 150
2
2.5.2
LED Indicators
Power polarity error (red)
Power on (green)
Warning (red)
Status (yellow)
TX (green)
Figure 16 - LED Indicators
The internal LEDs of the C-BOX 150 (see Figure above) indicate the following: POWER ON (PWR)
(green) indicates the C-BOX 150 is connected to the power supply and the power switch is ON.
POWER POLARITY ERROR
(red) indicates a wrong polarity. While activated, all other LEDs will be off until the power feed is connected with correct polarity.
WARNING (WL)
(red) indicates a warning or error condition. Off: the C-BOX 150 has terminated the Connection and/or the Update phase; all the operations have been executed successfully. ON: during a connection procedure and/or the Update phase (the system is busy) or during the C-BOX 150 Configuration Mode. It flashes quickly when a GET command has been preset at power on.
18