Page 29
INSTALLATION
2 1 blinking/sec: a requested operation has been terminated abnormally. 2 blinking/sec: a wrong operation has been requested (for example the configuration in memory is not compatible with the connected scanner).
STATUS (SL)
(yellow) indicates the status of the non-volatile memory support. Off: the memory is empty (no configuration on board). 1 blinking/sec: the memory is not empty (a Get scanner configuration service has been executed)*. 2 blinking/sec: the memory is not empty (a Get Scanner Configuration service has been executed); however the saved configuration is not compatible with the current scanner one.
TRANSMISSION (TX)
(green) indicates there is communication between the CBOX 150 and the scanner. This LED blinks during the connection procedure.
* This is the typical state after correct system installation.
19
Page 30
C-BOX 150
2
2.6 2.6.1
TYPICAL LAYOUTS 1000, 2000, 4000 Scanners
For 1000, 2000, 4000 Scanner Families, the C-BOX 150 can operate in point-to-point single scanner configuration layouts.
C-BOX 150 2
Scanner PWR supply
Laptop
3
1
1
Main serial interface
2
Auxiliary serial interface (Local Echo)
3
External Trigger (for On-Line mode)
Figure 17 – Typical one scanner Layout
20
Host
Page 31
INSTALLATION
2.6.2
2
6000, 8000 Scanners
For the 6k/8k scanner Families, the C-BOX 150 can operate in both point-to-point single scanner configuration layouts and in a whole cluster of scanners in Master/Slave layouts. Slave 2
Master
Slave1
CAB-610X
CAB-610X
C-BOX 150
BTK-6000 CAB-60XX
PS Encoder Host
CAB-610X CAB-610X
CAB-610X
CAB-63XX
BTK-6000
Slave 5
Slave 4
Slave 3 PWR-240
CAB-63XX
NOTE
In a Master/Slave layout with a great number of Slaves, a Power Supply Unit can be connected to the scanners and the C-BOX 150 can accept the scanner power by setting the Power Source Jumper in the right position. See paragraph 2.4.6
By default, C-BOX 150 is able to perform Backup/Restore of the whole cluster (Master and Slaves). The following conditions must be met: 1.
The Master/Slave network must be either Synchronized or Multidata.
2.
The A.S.R. mode must be disabled.
In order to perform Backup/Restore of Master only, the C-BOX 150 Cluster GET/SEND parameter must be configured to "Master only". See also WinHost Help online.
21
Page 32
C-BOX 150
2
2.7
SCANNER REPLACEMENT
If you have to replace the scanner with another one: 1.
Switch-off the system.
2.
Connect the new scanner.
3.
Switch-on the system.
4.
Wait until the Warning Led (WL, red) is switched Off.
Now the new scanner has been automatically (default) updated with the correct configuration!
22
Page 33
TECHNICAL FEATURES
3
3
TECHNICAL FEATURES
ELECTRICAL FEATURES Power Supply voltage Power consumption max. USER INTERFACE LED indicators
10 to 30 Vdc 2.5 W + scanner Power ON, Warning, Status Tx, Polarity inversion
PHYSICAL FEATURES Mechanical dimensions Weight
161 x 114.5 x 40 mm (6.34 x 4.51 x 1.57 in) about 410 g. (14.48 oz.)
SOFTWARE FEATURES Parameter storage
Non-volatile internal memory
ENVIRONMENTAL FEATURES Operating temperature
-10 to 50 °C (14 to 122 °F)
Storage temperature
-20 to 70 °C (-4 to 158 °F)
Humidity max. Vibration resistance IEC 68-2-6 test FC Shock resistance IEC 68-2-27 test EA Protection class
90% non condensing 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 2g @ 70-200 Hz 2 hours on each axis 30g; 11 ms; 3 shocks on each axis IP64 (when correctly connected to the scanner)
The features given are typical at a 25 °C ambient temperature (if not otherwise indicated). NOTE
23
Page 34
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy
06 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX-XXX e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y
92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022 (CLASS A ITE), August 1994: AMENDMENT A1 (CLASS A ITE), October 2000
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE
EN 61000-6-2, October 2001:
ELECTROMAGNETIC COMPATIBILITY (EMC). PART 6-2: GENERIC STANDARDS – IMMUNITY FOR INDUSTRIAL
CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT
ENVIRONMENTS
Lippo di Calderara, 05/05/2006 Ruggero Cacioppo Quality Assurance Laboratory Manager