Page 9

GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the C-BOX 150. 1) Read all information in the section "Safety Precautions" at the beginning of this manual. 2) Correctly position and mount the C-BOX 150 within the reach of the barcode scanner cable, according to the information in paragraph 2.3. 3) Make all electrical connections according to your application. See par. 2.4 and 2.6. Further typical layouts are given in the Scanner Reference Manual. 4) Set all the proper configuration jumpers and switches according to your application. See all sub-paragraphs under 2.4. 5) Connect the scanner to the C-BOX 150. 6) Switch-on the system. 7) Wait until the Warning Led (WL, red) is switched off. 8) Through the internal 9 pin male connector (it carries the Scanner Aux. Serial Port signals) configure the scanner according to your specific application; use WinHost for the 1000, 2000, 4000 Family, and Genius for the 6K/8K Family. 9) Force the 'Get Scanner Configuration' procedure using the internal keys (see paragraph 2.5.1). 10) Wait until the Warning Led (WL, red) is switched Off.

Now the C-BOX 150 contains the scanner configuration. The installation is complete.

vii

Page 10

viii

Page 11

INTRODUCTION

1

INTRODUCTION

1.1

PRODUCT DESCRIPTION

1

The C-BOX 150 is a connection box which can be used as an accessory to several Datalogic family scanners. Its main feature is to make the substitution of a Datalogic scanner in an installation plain and easy. To achieve this goal the C-BOX 150 provides the GET command to pass the connected scanner’s configuration to the C-BOX 150 non volatile memory. The SEND command allows a previously saved configuration to be transferred from the C-BOX 150 to the scanner. By default, at every power-on, the C-BOX 150 automatically sends the configuration stored in its memory to the connected scanner. Therefore the substituted scanner will be correctly configured. The C-BOX 150 allows you to perform the following functions: •

Facilitate the connection of the scanner signals using a spring clamp connector.

•

Get the scanner configuration and store it in memory.

•

Force the scanner to the Test operating mode.

•

Send the configuration stored in memory to the scanner.

The C-BOX 150 mechanical dimensions are 161 x 114.5 x 40 mm (6.34 x 4.51 x 1.57 in.). The C-BOX 150 weighs about 410 g (14.48 oz). Electrical connection is provided through spring clamp terminal blocks inside the CBOX 150. The scanner is connected to the C-BOX 150 through a 25-pin connector placed on the left side of the housing. A 9-pin connector placed inside the C-BOX 150 facilitates connection between an external PC and the auxiliary serial interface of the scanner.

1

Page 12

C-BOX 150

1

1.2

C-BOX 150 COMPATIBLE DEVICES

The C-BOX 150 can be connected to the following scanners through the 25-pin connector illustrated in Figure A. DS1100*

DS2400A

DS8100A

DS2100A

DS4600A

DX8200A

DS2200*

DS6X00

*10 and 30 Vdc versions only

2