Page 141

Specifications AccuLazr™ AL5010 Technical Specifications

Characteristic Name (1) Scan Head* 1 Laser, Standard Density 1 Laser, High Density 1L, High Density, Near Focus 2L, Low Density, High Pitch 2 Laser, High Density Optional Adjustable Raster (2) Mounting Base/Cable Size Weight Enclosure Temperature Relative Humidity Laser Type Power Requirement Power Consumption Visual Indicators (LEDs) Bar Code Types Connectors (Mounting Base) Communications Options Reliability Service Options Warranty Compliance

Description Mid Range Laser Bar Code Reader, AccuLazr™ AL5010 Line Scan Min Bar (mil) Depth of Field mm [inch] Part Number 1000067750 14-20 279.4[11”] 1000067751 7-13 228.6 [9”] 1000067757 7-13 127.0 [5”] 1000067753 1000067754 1000071308

Scans/ Second 700-1200 700-1200 700-1200

20+ 838.2 [33”] 600/laser 7-13 838.2 [33”] 600/laser Adjustable 20° above and below 0° (center); oscillating mirror

1 meter cable (0111623001); 3 meter cable (0111623002) H 104 mm [4.10”] x W 130.8 mm [5.15”] x D 49.9 mm [1.96”] Scan Head: 0.45 kg [1.0 lb] Mounting Bracket: 0.14 kg [0.3 lb] Mounting Base: 0.25-0.34 kg [0.56-0.75 lb] Powder-coated cast aluminum, high-impact plastic, rated for IP65 Operating: 0° to +40° C [+32° to +104° F] Storage: -20° to +70° C [-4° to +158° F] 10% - 90% non-condensing Visible laser diode 650 nm (Class 1) 12-28 VDC (power supplies available from Accu-Sort) < 25W Status, Trigger, Read, RX/TX, Network, Link; read quality (5 LEDs) All standard 1D symbologies 15-pin “D” Scanner connector, RJ45 connector for Ethernet On-board EtherNet/IP, Ethernet TCP/IP, Serial RS232/RS422, 4 programmable I/O relays, DeviceNet, Profibus (see AccuLazr Basic and Enhanced Interface Module datasheets) Universal Mounting Bracket (0111620001) Basic and Enhanced Interface Modules (see datasheets) > 50,000 hours MTBF @ 25° C [77° F] Installation assistance and on-site training 1-year limited, parts and labor UL, cUL, FCC (Class A), 21CFR1040, IEC-60825-1,CE, C-TICK

Accu-Sort reserves the right to change product specifications without notice.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 142

AccuLazr™ Basic Interface Module Technical Specifications Characteristic Name Size Weight

Description AccuLazr™ Basic Interface Module (0111631001) H 92.5 mm [3.64”] x W 136.4 mm [5.37”] x D 65.0 mm [2.56”] Basic Interface Module: 0.317 kg [0.7 lbs] Power Supply: 0.498 kg [1.1 lbs] Temperature Operating: 0° to +40° C [+32° to +104° F] Storage: -20° to +70° C [-4° to +158° F] Relative Humidity 10-90% non-condensing Enclosure High-impact plastic, rated for IP54 Power Requirements 12-28 VDC (power supplies available from Accu-Sort) Power Consumption < 25 W (max.) Power Supply 12-28 VDC (< 25W) (0111628001) Power Cord: 125V, 10A, 2.3 meter [7.6 ft] long (0102414001) 230V, 10A, 2.4 meter [8.0 ft] long (0102713001) Visual Indicators LEDs – Power, Trigger Connections Terminal Blocks rated for 16-24 AWG wire Standard RJ45 and 15-pin ‘D’ connections from mounting base Communications Ethernet, Serial RS232/RS422 (selectable) Reliability > 50,000 hours MTBF @ 25° C [77° F] Service Options Installation assistance and on-site training Warranty 1-year limited, part and labor Compliance UL, cUL, FCC (Class A), 21CFR1040, IEC-60825-1, CE, C-TICK (See Compliance table in this appendix.) Accu-Sort reserves the right to change product specifications without notice.

AccuLazr™ Enhanced Interface Module Technical Specifications Characteristic Name Size Weight

Description AccuLazr™ Enhanced Interface Module 133.6 mm [5.26“] H x 191.4 mm [7.54“] W x 67.0 mm [2.64“] D Enhanced Interface Module: 0.589 kg [1.3 lbs] (no I/O modules) Power Supply: 0.498 kg [1.1 lbs] Temperature Operating: 0° to +40° C [+32° to +104° F] Storage: -20° to +70° C [-4° to +158° F] Relative Humidity 10-90% non-condensing Enclosure High-impact plastic, rated for IP65 Power Requirements Input: 12-28 VDC (power supplies available from Accu-Sort) Power Consumption < 25 W (max.) Power Supply 12-28 VDC (< 25W) (0111628001) Power Cord: 125V, 10A, 2.3 meter [7.6 ft] long (0102414001) 230V, 10A, 2.4 meter [8.0 ft] long (0102713001) Visual Indicators LEDs – Power, Trigger, Tach, RX/TX1-2, DeviceNet, Profibus, I/0 1-4 Connections Terminal Blocks rated for 20-24 AWG wire (power is 16-24 AWG) Standard RJ45 and 15-pin ‘D’ connections from mounting base Communications Serial RS232/RS422 (2), Ethernet TCP/IP, DeviceNet, Profibus and up to 4 programmable I/O relay modules Options Tachometer: Programmable, 8-30VDC, 20 ft. cable (1000066479) General Mounting (1000020567) Extrusion Mounting (1000020568) Photoeye: incl. hardware/reflector (1000020569) I/O Modules: Input 3.3-32VDC (1000056135) Output 3-60VDC (1000056136) Output 12-42VACPeak (1000056137) Reliability > 50,000 hours MTBF @ 25° C [77° F] Service Options Installation assistance and on-site training Warranty 1-year limited, part and labor Compliance UL, cUL, FCC (Class A), 21CFR1040, IEC-60825-1, CE, C-TICK (See Compliance table in this appendix.) Accu-Sort reserves the right to change product specifications without notice.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 143

Power Supply for AL5010 Characteristic

Dimensions Weight Temperature

Relative Humidity Enclosure Power Requirements Power Consumption Connections Compliance

Description

L 4.65” [118 mm] x W 1.36” [34.5 mm] x H 2.05” [52 mm] 0.6 lbs. [0.275 kg] Operating: 0° to +70° C Storage: -40° to +85° C 5-95% non-condensing ABS plastic, Rated for IP40 Input: 90-264 VAC / 0.5A typical, 1.0A max. @ 120 VAC Output: Max. 250mA Load < 40 W Male IEC (available with either domestic or international power cord) UL, cUL, CE, FCC (Class A) (See Compliance table.)

Output Modules Part Number 1000056136 1000056137 Maximum Line Voltage 60 VDC 42 VAC Minimum Line Voltage 3.0 VDC 12 VAC Maximum Peak Off State Voltage 60 VDC 42 VAC peak Maximum Peak Off State Leakage 1.0 mA 2.5 mA RMS Static off–state dv/dt -200 V/usec Maximum On–State Current 0.5 A DC 0.5 A RMS Minimum On–State Current 10 mA DC 50mA RMS Maximum 1 Cycle Surge -4 A peak Maximum 1 Second Surge 1.5 A DC -Peak On–State Voltage 1.5 V DC 1.6 V peak *NOTE: Relay modules are only for connection to SELV, LPS power source and shall also meet the requirements for Class 2.

Input Module Part Number Maximum Input Voltage Minimum Input Voltage Input Resistance Maximum Input Current Drop Out Current Allowable Off–State Input Current Allowable Off–State Input Voltage * NOTE: Compatible with TTL level voltages.

1000056135 * 32 VDC 3.3 VDC 1 k ohm 32mA DC@ 32 VDC 1.0 mA DC 1.0 mA DC 2.0 VDC

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 144

136

AccuLazr™ AL5010 Product Line Manual

Appendix A: Specifications

Certifications UL Listing

UL Listed UL Listed to Canadian safety standards Standard to which conformity is declared: EN60950: Test Spec: IEC 60950 3RD Edition / (2000) (Information Technology Equipment (I.T.E.), Including Electrical Business Equipment

Standards to which conformity is declared: FCC 47 CFR, Part 15, subpart B, “Unintentional Radiators” CLASS A Radiated Emissions and CLASS B Conducted Emissions

Standards to which conformity is declared: 1 Emissions EN 61000-6-4: 2001 CISPR 11:1999 Radiated Emissions – Class A CISPR 11:1999 Conducted Emissions – Class A 2 Immunity EN 61000-6-2: 2001 Electromagnetic Compatibility - Generic Standards Immunity for industrial environments EN 61000-4-2:1995, Electromagnetic compatibility (EMC), Electrostatic discharge immunity test EN 61000-4-3: 2001, (EMC), Part 4 - Section 3: Radiated, radio-frequency electromagnetic field test EN 61000-4-4:2004, (EMC), Electrical fast transient/burst immunity test EN 61000-4-5:1995, (EMC), Part 4 - Section 5 Surge immunity test EN 61000-4-6:2003, (EMC), Part 4 - Section 6 Immunity to conducted disturbances, induced by radio-frequencies IEC 61000-4-11: 2003, (EMC), Part 4 - Section 11 Voltage dips, short interruptions & variations immunity IEC 61000-3-2 A14, 3/2000 and 61000-3-3: Harmonic current emissions Fluctuating and Steady State Harmonics) ENV 50204: 1995, "(EMC), Radiated, Electromagnetic Field From Digital Radio Telephones-Immunity Test"

C-TICK: N2468, DATALOGIC AUTOMATION PTY, Australia / New Zealand

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 145

Read Charts

How to identify the scan head model: The model type is shown on the serial label.

1L – Indicates a scan head that is using one laser. 2L – Indicates a scan head that is using two lasers. SD – Identifies a standard density scan head for reading bar codes with minimum bar/space widths of 15 mil+. HD – Identifies a high density scan head for reading bar codes with minimum bar/space widths of 10 mil+. NHD – Identifies a near focus, high density scan head for reading bar codes with minimum bar/space widths of 10 mil+. IMPORTANT: All read charts are subject to change without notice.

NOTE: An Ultra-Near Focus model is also available with a depth of field from 4 to 20 inches. Please contact Accu-Sort Systems for details relating to your application.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 146

Combo Read Chart / Table

1,200 scans per second (standard) throughout DOF ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 °

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 147

AL5010-1L NHD: 1 Laser, Near Focus High-Density Scan Head Part Number 1000067752 10 mil code

1,200 scans per second (standard) throughout DOF ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 °

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 148

AL5010-1L HD: 1 Laser, High-Density Scan Head Part Number 1000067751 10 mil code

1,200 scans per second (standard) throughout DOF ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 °

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 149

AL5010-1L HD: 1 Laser, High-Density Scan Head Part Number 1000067751 14 mil code

1,200 scans per second (standard) throughout DOF ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 °

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 150

AL5010-1L HD: 1 Laser, High-Density Scan Head Part Number 1000067751 20 mil code

1,200 scans per second (standard) throughout DOF ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 °

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net