Page 131

System Counters Log View You can display a number of values and counters that indicate whether the AL5010 is configured and operating properly by clicking the System Counters button. You can also enter DISPCOUNTERS in the command field and click Send. Scan Rate and Belt Speed System Counters Scan Rate

Belt Speed

Description This is the total number of scans/second that the AL5010 is reading. Note the this number does NOT take into account “laser toggling” if it is enabled. If “laser toggling” is enabled, the effective scan rate for any laser is half of this value. (tracking) Speed of the belt (in ft/min) as measured by the tachometer.

Bar Code Counters Bar Code Counters Triggers

Good Reads No Reads Mult Codes

Match Codes Bad ModChk

Error Counters Error Counters Xfter Ovrflw

Xfer BadLen QData@TX

QData@Trig

Description Total number of packages based on the trigger signal. In self-trigger mode, this will match the number of good reads. Total number of bar codes read and transmitted. If the AL5010 is set up to read multiple bar codes each trigger, this counter is incremented for each bar code read. Total number of bar codes that were not read. Total number of instances where more bar codes of a specific type were read than expected. This counter will also increment, regardless of whether the AL5010 is configured to report “multiple codes” as an error. Total number of bar codes that matched any of the Match Code criteria. Total number of bar codes that were rejected due to an invalid Mod Check.

Description Transfer Overflow. This counts the number of codes that were lost due to an overflow in the transfer buffer between the Decode/DSP processor and the AL5010/ARM processor. Transfer Bad Length. Number of codes in the transfer buffer than contained an invalid length, indicating some sort of memory corruption. Queue Data at Transmit (non-tracking). This counter indicates that the AL5010 had not completed processing all of the scan data at the user specified transmit time. This will only happen if the “transmit time” parameter is set to a value other than zero. This does not necessarily indicate an error, but does indicate that either the transmit time is too short or the AL5010 is seeing a lot of data which may be the result of too much background noise. Queue Data at Trigger (non-tracking). This counter indicates that the AL5010 had not completed processing all of the scan data prior to the start of the next trigger. This typically can only happen when the “transmit time” parameter is set to zero; although it can also happen in conjunction with a Force Transmit. As with the Queue Data at Transmit counter, this does not necessarily indicate an error, but it likely indicates that the AL5010 is seeing a lot of data which may be the result of too much background noise.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 132

ForcedTx Lost Codes

Missed Tx

Forced Transmit (non-tracking). A forced transmit indicates that the start of trigger occurred before the specified transmit delay time had expired. Lost Codes (tracking). If a bar code cannot be placed onto any package while in tracking, the code is “lost” and this counter is incremented. Lost codes are also reported in the AL5010 Monitor message window. Lost code occurances typically indicate tracking parameters need to be adjusted. Missed Transmit (tracking). If a bar code is decoded after the message for that package has been transmitted, the Missed Transmit counter is incremented.

Decode/DSP Counters Decode/DSP Counters DSP Codes Scan Ints Queue Size Num Cluster Bad Scan Pipe Error Full Scans Mem Full ScanTooLong Max Clusters

Description

Count of the number of barcodes decoded, per laser, by the DSP. Number of scan interupts detected by the DSP. Current size of the scan data queue within the DSP. This value changes dynamically. Current number of DRX clusters in use by the DSP. This value changes dynamically. Count of the number of scans in which the data contained formatting errors. Count of internal errors on the transfer of scan data from the scan data buffer. Number of times a scan could not be added to the scan data buffer because the maximum number of scans was exceeded. Number of times a scan could not be added to the scan data buffer because the memory was full. Number of times a scan was skipped because it contained too many transitions. Number of times, the maximum number of DRX clusters was exceeded.

ARM and DSP Restarts Counters ARM Restarts DSP Restarts

Description Number of times the ARM processor has restarted. This typically means the hardware watchdog timer expired causing the ARM processor to restart. Number of times the DSP processor has been restarted. Typically, this happens if the ARM suspects the DSP has “locked up” for any reason.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 133

Message Log View The Message Log contains various text messages that have been logged by the AL5010 software. You can view these messages by clicking the Message Log button. You can also enter DISPMSGLOG in the command field and click Send. The messages contained in this log typically reflect significant events.

Update Firmware CAUTION: Used to reload AL5010 reader firmware. This function should only be performed under the guidance of Accu-Sort Technical Support.

Diagnostics > Update Firmware Extracting an Image: 1. Click the Extract Image button. 2. The Save As window enables you to save image (*.as) files. Burning an Image to Flash: 1. Click the Burn Flash button. 2. The Open window enables you to open an image file (*.as*) 3. Burn the image file to flash.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 134

Troubleshooting The following PCS (problem/cause/solution) tables are designed to assist you in troubleshooting the more common events that may occur during installation and operation of your AccuLazr AL5010. PCS Troubleshooting Problem Cause(s) Solution(s)

Problem Cause(s) Solution(s)

Problem Cause(s) Solution(s)

The POLARITY LED in the wiring base is RED. Wiring from the power supply to the INPUT POWER terminal block is incorrectly wired. IMPORTANT: DO NOT install the scan head if polarity LED is RED. 1. Correct the polarity problem by swapping the wires at the INPUT POWER terminal block. 2. Confirm power polarity is correct (GREEN LED). 3. Install the scan head. (See Chapter 3.) There is no laser light exiting from the AL5010 when power is activated. Have the laser(s) been shut off? No power is provided to the AL5010. 1. Check to ensure power is properly connected. 2. Check to see if AL5010 Status LED turns ON. 3. Confirm power supply functioning. 4. Remove AL5010 scan head from wiring base. 5. Verify Power LED in wiring base is GREEN. 6. If Power LED is RED, polarity is swapped. 7. If Power LED is OFF, check wiring at the INPUT POWER terminal block. 8. Replace the power supply if wiring was correct. 9. Reassemble AL5010 scan head to wiring base. The AL5010 is not reading bar codes. Code type is not enabled or wrong code length. Code passes by at too large an angle (tilt, pitch, skew). All codes have very poor print quality. 1. Enable code type or correct code length. 2. Make sure laser beam is ON when code passes by. 3. Verify correct bar code parameters are enabled. 4. Enable TEST MODE. (Use the AL5010 control panel button) 5. Hold code in the scan line. 6. Verify the AL5010 is reading the code. 7. Correct any tilt, pitch, or skew problems. 8. Remedy bar code printing problems.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 135

PCS Troubleshooting (continued) Problem Cause(s) Solution(s)

The AL5010 is experiencing poor read rate. Poorly printed bar codes. Scan head window is dirty. Codes passing by at too large an angle (tilt, pitch, skew). 1. Confirm the quality of bar code printing is good enough to read. Correct any print quality issues. 2. Clean scan head window as defined Chapter 7. 3. Check reading distance with a known good quality sample bar code. 4. Enable TEST MODE. (Use the AL5010 control panel button.) 5. Hold code in the scan line. 6. Verify the AL5010 is reading the code. 7. Correct any tilt, pitch, or skew problems.

Problem Cause(s) Solution(s)

The AL5010 is experiencing poor read rate in hardware trigger. Photoeye is not adjusted properly or requires alignment. 1. Verify that the photoeye is blocked the entire time the reader’s laser is scanning the bar code. 2. Adjust the photoeye as necessary. (See Verify Photoeye Operation in Chapter 7.) NOTE: For non-tracking applications only.

Problem Cause(s)

HOST is not receiving serial host message. Improper wiring between host and reader. Incorrect configuration settings. 1. Is the AL5010’s RX/TX LED flashing GREEN? 2. If yes, check the serial cable wiring at the wiring base’s SERIAL COM terminal block and at the HOST. 3. If no, verify AL5010 trigger input and trigger configuration. 4. View the Message Monitor to verify the AL5010 is transmitting data from the SERIAL COM port. (See Diagnostics > Monitor.)

Solution(s)

Problem Cause(s) Solution(s)

Problem Cause(s) Solution(s)

AL5010 reads bar codes, but transmits a NO READ message. (Tracking Applications Only) Improper tracking configuration 1. Check for “Code Lost” messages using diagnostics. 2. If “Code Lost” messages are present, check the tracking configuration. (See Tracking.) 3. Correct as needed. Cannot connect configuration PC running to the AL5010’s Ethernet port. Improperly configured Ethernet port on configuration PC 1. Verify network port configuration on PC. 2. Port on PC must be configured for a static IP address.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 136

Discovering the IP Address If you don’t know the IP address for the AL5010 unit, it can be found in two ways. To Discover the IP Address Using Recovery Mode: 1. Unplug the power to the AL5010 system. 2. Hold down the “!” button on the back of the reader while you restore power. 3. Release the button. The LEDs should strobe from 5 to 1 and the status LED will be RED indicating that the unit is in Recovery Mode. 4. Open a browser and type 192.168.3.100 in the address bar. 5. The AL5010 recovery screen opens. The screen displays the IP address for the unit as well as the user name and password for the User Interface.

6. Note the IP address for the unit and click REBOOT. The AL5010 reboots and the AL5010 Login screen opens. To Discover the IP Address Using a Terminal Emulation Program: 1. Connect a laptop computer to one of the serial blocks in the interface module (Basic or Enhance) using a serial cable with flying leads (See the Electrical Installation section of this manual). NOTE: Make sure the baud rate, stop bits, etc match the serial port to which you are connected.

2. Launch a terminal emulation program on your laptop computer (i.e.: HyperTerminal, Tera Term, etc.) 3. Type IpAdDr in the terminal emulation program. If everything is set up correctly, the IP address will be displayed. NOTE: Since these processes are performed with a direct connection to the individual reader, there are no security issues.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 137

!!"#$%&'( #)*+*(,&-."!/(#012(3$1"$4

!"#$%&"

!!52&60!2( *+"#" ,#" , -%.%/"0 12.3"# 45 5%"-06#"7-,&",3-" 21%/8 9:;<8= /+,/ ,#" 7,#/ 45 /+" >?@A'AB C1 .48/ &,8"8D &4.741"1/8 8+42-0 3" #"7-,&"0 E%/+ , .,/&+%1F #"&4.."10"0 87,#" 7,#/ 9;!G=B

!"#$%&" 7#4&"02#"8 ,#" 0%$%0"0 %1/4 /E4 8H%-- -"$"-8I J28/4."# /"&+1%&%,18 9E%/+ 84." /#,%1%1F 5#4. >&&26!4#/= >&&26!4#/ *#,%1"0 ,10 >2/+4#%K"0 !"#$%&" *"&+1%&%,18 41-L >-- >?@A'A ,&&"884#%"8 ,10 47/%418 ,#" &418%0"#"0 &28/4."# /"&+1%&%,1 5%"-06#"7-,&",3-" 21%/8 9:;<8=B

*+" 5%"-06#"7-,&",3-" 21%/8 9:;<8= ,#" %0"1/%5%"0 %1 /+%8 &+,7/"#B

7284$!2921/(,&-!2."&2:( ; <=>?@I *+%8 8L.34- %10%&,/"8 L42 ,#" ,342/ /4 7"#54#. ,1 ,&/%41 %1$4-$%1FD "%/+"# , 0,1F"#428 -"$"- 45 $4-/,F"D 4# /4 E,#1 ,F,%18/ ,1 ,&/%41 /+,/ &42-0 #"82-/ %1 0,.,F" /4 0"$%&"8 4# "-"&/#%&,- 8+4&HB G-",8" 54--4E 1"&"88,#L 7#4&"02#"8 ,8 42/-%1"0 %1 !"#$%&' () *#+&%,B

A5B(; <=>?@I *+%8 8L.34- %0"1/%5%"8 , 7#4&"02#" /+,/ #"M2%#"8 L42 /,H" .",82#"8 /4 7#"$"1/ N-"&/#48/,/%& O%8&+,#F" 9N!O= "BFBD 28" ,1 N!O E#%8/ 8/#,7B J%#&2%/ 34,#08 ,#" .48/ ,/ #%8HB G-",8" 54--4E N!O 7#4&"02#"8 ,8 42/-%1"0 %1 !"#$%&' () *#+&%,B

AC/2&1$4(B260!2:( *4 #"7-,&" ,1L "P/"#1,- 0"$%&"8D #"5"#"1&" /+" %18/,--,/%41 7#4&"02#"8 7#4$%0"0 %1 J+,7/"# Q ,10 J+,7/"# RB

D024.(7284$!2$E42(<10/:(FD7<:G( ;"7-,&"."1/ 7#4&"02#"8 54# 5%"-06#"7-,&",3-" 21%/8 9:;<8= /+,/ .,L 3" 7"#54#."0 3L &28/4."# /"&+1%&%,18 ,#" 7#4$%0"0 E%/+ /+" #"7-,&"."1/ 7,#/B

; <=>?@H >1 "10 28"# 4# 8L8/".8 %1/"F#,/4# E%/+ 3,8%& "-"&/#4."&+,1%&,- ,10 /"&+1%&,- 8H%--8 .,L 7"#54#. /+" #".4$,- ,10 #"7-,&"."1/ 45 /+" 5%"-0 #"7-,&",3-" 21%/8 9:;<8= -%8/"0 3"-4EB S4E"$"#D >&&26!4#/ /#,%1%1F %8 #"&4.."10"0B J41/,&/ J28/4."# !"#$%&" ,/ '6TAA6 U>;6JVON /4 8&+"02-" /#,%1%1F /+,/ 5%/8 L42# 1""08B

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

'()

Page 138

FRU Guide

Spare Part Number

Replacement Assembly Descriptions

1000067750

Scan Head (1L-SD)

1-laser, standard density

1000067751

Scan Head (1L-HD)

1-laser, high density

1000067752

Scan Head (1L-NHD)

1-laser, near focus, high density

1000067753

Scan Head (2L-SD)

2-laser, standard density

1000067754

Scan Head (2L-HD)

2-laser, high density

AL5010 Bar Code Reader

1000070389

NOTE: For Adjustable Raster versions or units with custom software installed, please contact Customer Service at 1-800-BARCODE to obtain your correct field replaceable units. Please have the unit serial number or order E-number available when you contact Accu-Sort.

1000070388

0111623001

Mounting Base

1-meter cable

0111623002

Mounting Base

3-meter cable

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 139

FRU Guide

Spare Part Number

Replacement Assembly Descriptions

AL5010 Interface Module

1000070391

0111631001

Basic Interface Module Trig, Ethernet, (1) serial port (RS232/422 selectable)

1000070384

0111633001

Enhanced Interface Module with DeviceNet Tach, Trig, Ethernet, (2) serial port (RS232/422 selectable), (4) I/O

0111633002

Enhanced Interface Module with DeviceNet Tach, Trig, Ethernet, (2) serial port (RS232/422 selectable), (4) I/O

0111633003

Enhanced Interface Module with Profibus Tach, Trig, Ethernet, (2) serial port (RS232/422 selectable), (4) I/O

1000068248

DeviceNet Replacement Module (Anybus-IC 32-pin)

1000068247

Profibus Replacement Module (Anybus-IC 32-pin)

1000056135

DC Input Module (White): 3.3-32 VDC (32 mA)

1000056136

DC Output Module (Red): 3-60 VDC (3 A max.)

1000056137

AC Output Module (Black): 12-42 VACPeak (3 A max.)

1000070387

1000020569

Trigger Photoeye, flying leads

1000070390

1000066479

Tachometer, programmable, 8-30 VDC

N/A

0111628001

Power Supply 40 Watt, 12 VDC

1000070385 1000070386

Other FRUs

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 140

132

Service

AccuLazr™ AL5010 Product Line Manual

Notes:

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net