The text of a manual · part 11 of 20
Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide: Symbologies, pages 95 to 104
Pages 95 to 104 of 184, from Magellan 1400i On-Counter Presentation Omnidirectional Bar Code Reader Product Reference Guide
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 1400i
Page 95
GS1 DataBar Expanded / Expanded Stacked
GS1 DataBar Expanded / Expanded Stacked, continued GS1 DataBar Expanded Length 1, Length 2 Programming Instructions 1. Scan the START/END barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation. For GS1 DataBar Expanded barcodes, only the data characters are included in the length calculations. NOTE
4. Scan the START/END barcode. START / END PROGRAMMING BAR CODES
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 008
Set Length 2 ³ DEFAULT SETTING FOR THIS FEATURE: 014
Product Reference Guide
5-21
Page 96
Symbologies
GS1 DataBar Expanded / Expanded Stacked, continued Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Expanded label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
5-22
Magellan® 1400i
Page 97
GS1 DataBar Expanded / Expanded Stacked
GS1 DataBar Expanded / Expanded Stacked, continued Coupon Read Control This feature controls coupon reading. START / END PROGRAMMING BARCODES
Disable coupon filtering
Enable UPCA coupon decoding Disable GS1 DataBar coupon decoding DEFAULT
Enable GS1 DataBar coupon decoding Disable UPCA coupon decoding
Product Reference Guide
5-23
Page 98
Symbologies
GS1 DataBar Limited The following options apply to the GS1 DataBar Limited symbology.
Disable/Enable GS1 DataBar Limited When this feature is disabled, the scanner will not read GS1 DataBar Limited barcodes. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Limited DEFAULT
Enable GS1 DataBar Limited ³
5-24
Magellan® 1400i
Page 99
GS1 DataBar Limited
GS1 DataBar Limited, continued GS1 DataBar Limited 128 Emulation When enabled, GS1 DataBar Limited barcodes will be translated to the GS1 128 label data format. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Limited 128 Emulation DEFAULT
Enable GS1 DataBar Limited 128 Emulation
Minimum Reads This feature specifies the minimum number of consecutive times an GS1 DataBar Limited label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-25
Page 100
Symbologies
Code 39 The following options apply to the Code 39 symbology.
Disable/Enable Code 39 When this feature is disabled, the scanner will not read Code 39 barcodes. START / END PROGRAMMING BAR CODES
Disable Code 39
Enable Code 39 DEFAULT
Check Character Calculation When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code 39 labels. START / END PROGRAMMING BAR CODES Disable Check Char Calculation DEFAULT
Enable Check Char Calculation
5-26
Magellan® 1400i
Page 101
Code 39
Code 39, continued Check Character Transmit Enable this option to transmit the check character with scanned barcode data. START / END PROGRAMMING BAR CODES Disable Check Char Transmission
Enable Check Char Transmission DEFAULT
Start/Stop Characters Enables/disables transmission of Code39 start and stop characters. START / END PROGRAMMING BAR CODES Don’t Transmit Start/Stop Characters DEFAULT
Transmit Start/Stop Characters
Product Reference Guide
5-27
Page 102
Symbologies
Code 39, continued Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters. START / END PROGRAMMING BAR CODES Disable Code 39 Full ASCII DEFAULT
Enable Code 39 Full ASCII
5-28
Magellan® 1400i
Page 103
Code 39
Code 39, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the Code 39 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the Code 39 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the Code 39 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the Code 39 Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT
Fixed Length Decoding
Product Reference Guide
5-29
Page 104
Symbologies
Code 39, continued Code 39 Length 1, Length 2 Programming Instructions 1. Scan the START/END barcode. 2. Scan either the Set Length 1 or Set Length 2 barcode. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) representing the length in decimal notation.
NOTE
For Code 39 barcodes, all check, data and full ASCII shift characters (even if full ASCII is enabled) are included in the length calculations. Start/Stop characters are not included.
4. Scan the START/END barcode. START / END PROGRAMMING BAR CODES
Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 2 DEFAULT SETTING FOR THIS FEATURE: 050
Quiet Zones This feature enables/disables the requirement that quiet zones must be present for Code 39 barcodes. START / END PROGRAMMING BAR CODES Don’t require Quiet Zones DEFAULT
Require Quiet Zones ³
5-30
0
0
1
Magellan® 1400i