Page 85

EAN-13

EAN-13, continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads ³

Product Reference Guide

0 0 6

0

5-11

Page 86

Symbologies

EAN-8 The following options apply to the EAN-8 symbology.

Disable/Enable EAN-8 When disabled, the scanner will not read EAN-8 barcodes. START / END PROGRAMMING BAR CODES

Disable EAN-8

Enable EAN-8 DEFAULT

Check Digit Transmission Enable this option to transmit the check Digit along with EAN-8 barcode data. START / END PROGRAMMING BAR CODES

Don’t Send Check Digit

Send Check Digit DEFAULT

5-12

Magellan® 1400i

Page 87

EAN-8

EAN-8, continued Expand EAN-8 to EAN-13 - Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. START / END PROGRAMMING BAR CODES Don’t Expand to EAN-13 DEFAULT

Expand to EAN-13

Minimum Reads This feature specifies the minimum number of consecutive times an EAN-8 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads ³

Minimum = 3 Reads

Minimum = 4 Reads

Product Reference Guide

5-13

Page 88

Symbologies

Enable EAN Two-Label Enables/disables the ability of the scanner to decode EAN two-label pairs. START / END PROGRAMMING BAR CODES

Disable EAN Two-Label

Enable EAN Two-Label

Enable EAN Two-Label Combined Enables/disables the transmitting of an EAN two label pair as one label. START / END PROGRAMMING BAR CODES

Disable EAN Two-Label Combined

Enable EAN Two-Label Combined

Contact Customer Support for advanced programming of NOTE Two-Label Pairs.

5-14

Magellan® 1400i

Page 89

Add-ons

Add-ons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN barcodes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are: None - This option directs the scanner to ignore add-on portion of a UPC/EAN barcode but still read the main portion of the barcode. 2 Digits - The scanner will optionally read 2-digit add-ons with the UPC/EAN label. 5 Digits - The scanner will optionally read 5-digit add-ons with the UPC/EAN label. Code 128 Add-on - The scanner will optionally read Code 128 add-ons with the UPC/EAN label.

NOTE

Product Reference Guide

Contact Customer Support for advanced programming of optional and conditional add-ons.

5-15

Page 90

Symbologies

Add-ons, continued START / END PROGRAMMING BAR CODES Disable Optional 2-Digit Add-ons DEFAULT

Enable Optional 2-Digit Add-ons

Disable Optional 5-Digit Add-ons DEFAULT

Enable Optional 5-Digit Add-ons ³

0

1 1 0 1

Disable Optional Code 128 Add-ons DEFAULT

Enable Optional Code 128 Add-ons

5-16

Magellan® 1400i

Page 91

GS1 DataBar Omnidirectional / Stacked Ominidirectional

GS1 DataBar Omnidirectional / Stacked Ominidirectional The following options apply to the GS1 DataBar Omnidirectional symbology.

Disable/Enable GS1 DataBar Omnidirectional When this feature is disabled, the scanner will not read GS1 DataBar Omnidirectional barcodes. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Omnidirectional DEFAULT

Enable GS1 DataBar Omnidirectional

GS1 128 Emulation When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1 128 label data format. START / END PROGRAMMING BAR CODES Disable GS1 128 Emulation DEFAULT

Enable GS1 128 Emulation

Product Reference Guide

5-17

Page 92

Symbologies

GS1 DataBar Omnidirectional / Stacked Ominidirectional, continued Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT

Minimum = 2 Reads

Minimum = 3 Reads

Minimum = 4 Reads

5-18

Magellan® 1400i

Page 93

GS1 DataBar Expanded / Expanded Stacked

GS1 DataBar Expanded / Expanded Stacked The following options apply to the GS1 DataBar Expanded symbology.

Disable/Enable GS1 DataBar Expanded When this feature is disabled, the scanner will not read GS1 DataBar Expanded barcodes. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Expanded DEFAULT

Enable GS1 DataBar Expanded

GS1 DataBar Expanded 128 Emulation When enabled, GS1 DataBar Expanded barcodes will be translated to the GS1 DataBar Expanded 128 label data format. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Expanded 128 Emulation DEFAULT

Enable GS1 DataBar Expanded 128 Emulation

Product Reference Guide

5-19

Page 94

Symbologies

GS1 DataBar Expanded / Expanded Stacked, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT

Fixed Length Decoding

5-20

Magellan® 1400i