Page 85
EAN-13
EAN-13, continued Minimum Reads This feature specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads ³
Product Reference Guide
0 0 6
0
5-11
Page 86
Symbologies
EAN-8 The following options apply to the EAN-8 symbology.
Disable/Enable EAN-8 When disabled, the scanner will not read EAN-8 barcodes. START / END PROGRAMMING BAR CODES
Disable EAN-8
Enable EAN-8 DEFAULT
Check Digit Transmission Enable this option to transmit the check Digit along with EAN-8 barcode data. START / END PROGRAMMING BAR CODES
Don’t Send Check Digit
Send Check Digit DEFAULT
5-12
Magellan® 1400i
Page 87
EAN-8
EAN-8, continued Expand EAN-8 to EAN-13 - Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. START / END PROGRAMMING BAR CODES Don’t Expand to EAN-13 DEFAULT
Expand to EAN-13
Minimum Reads This feature specifies the minimum number of consecutive times an EAN-8 label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads ³
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-13
Page 88
Symbologies
Enable EAN Two-Label Enables/disables the ability of the scanner to decode EAN two-label pairs. START / END PROGRAMMING BAR CODES
Disable EAN Two-Label
Enable EAN Two-Label
Enable EAN Two-Label Combined Enables/disables the transmitting of an EAN two label pair as one label. START / END PROGRAMMING BAR CODES
Disable EAN Two-Label Combined
Enable EAN Two-Label Combined
Contact Customer Support for advanced programming of NOTE Two-Label Pairs.
5-14
Magellan® 1400i
Page 89
Add-ons
Add-ons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN barcodes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are: None - This option directs the scanner to ignore add-on portion of a UPC/EAN barcode but still read the main portion of the barcode. 2 Digits - The scanner will optionally read 2-digit add-ons with the UPC/EAN label. 5 Digits - The scanner will optionally read 5-digit add-ons with the UPC/EAN label. Code 128 Add-on - The scanner will optionally read Code 128 add-ons with the UPC/EAN label.
NOTE
Product Reference Guide
Contact Customer Support for advanced programming of optional and conditional add-ons.
5-15
Page 90
Symbologies
Add-ons, continued START / END PROGRAMMING BAR CODES Disable Optional 2-Digit Add-ons DEFAULT
Enable Optional 2-Digit Add-ons
Disable Optional 5-Digit Add-ons DEFAULT
Enable Optional 5-Digit Add-ons ³
0
1 1 0 1
Disable Optional Code 128 Add-ons DEFAULT
Enable Optional Code 128 Add-ons
5-16
Magellan® 1400i
Page 91
GS1 DataBar Omnidirectional / Stacked Ominidirectional
GS1 DataBar Omnidirectional / Stacked Ominidirectional The following options apply to the GS1 DataBar Omnidirectional symbology.
Disable/Enable GS1 DataBar Omnidirectional When this feature is disabled, the scanner will not read GS1 DataBar Omnidirectional barcodes. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Omnidirectional DEFAULT
Enable GS1 DataBar Omnidirectional
GS1 128 Emulation When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1 128 label data format. START / END PROGRAMMING BAR CODES Disable GS1 128 Emulation DEFAULT
Enable GS1 128 Emulation
Product Reference Guide
5-17
Page 92
Symbologies
GS1 DataBar Omnidirectional / Stacked Ominidirectional, continued Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as a good read. START / END PROGRAMMING BAR CODES Minimum = 1 Read DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
5-18
Magellan® 1400i
Page 93
GS1 DataBar Expanded / Expanded Stacked
GS1 DataBar Expanded / Expanded Stacked The following options apply to the GS1 DataBar Expanded symbology.
Disable/Enable GS1 DataBar Expanded When this feature is disabled, the scanner will not read GS1 DataBar Expanded barcodes. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Expanded DEFAULT
Enable GS1 DataBar Expanded
GS1 DataBar Expanded 128 Emulation When enabled, GS1 DataBar Expanded barcodes will be translated to the GS1 DataBar Expanded 128 label data format. START / END PROGRAMMING BAR CODES Disable GS1 DataBar Expanded 128 Emulation DEFAULT
Enable GS1 DataBar Expanded 128 Emulation
Product Reference Guide
5-19
Page 94
Symbologies
GS1 DataBar Expanded / Expanded Stacked, continued Length Control Fixed Length Decoding - When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths. Variable Length Decoding - When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START/END barcode. 2. Scan the Fixed Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first fixed length by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START/END barcode. 2. Scan the Variable Length Decoding barcode. 3. Scan the START/END barcode. 4. Set Length 1 to the first variable length by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second variable length by following the GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below. START / END PROGRAMMING BAR CODES Variable Length Decoding DEFAULT
Fixed Length Decoding
5-20