The text of a manual · part 5 of 7
PC9800 & PC9800LS User's Guide, pages 37 to 45
Pages 37 to 45 of 62
The original document is the PDF (555 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the DAP PC9800
Page 37
25
VOICE SYSTEM (optional) As an option, the PC9800 can be supplied with a Record/Playback Voice System. When installed, the Voice System allows the user to listen to prerecorded messages or instructions, and to record the user’s own messages and play them back. The Voice System is composed of a speaker and a microphone in addition to a Voice Processing chip, inside the unit. You can locate them in FIGURE 3. The behavior of the Voice Interface is mainly under the control of an application program and a special software driver. It is then impossible to describe here precisely how they will handle it. You should refer to your application program user’s guide for complete details. In the meantime, the following presents the basic information. The method - To record a message or listen to a message - To listen to a pre-recorded message or a message you just recorded - To delete a message or modify one depends on the application program and cannot be described here. · To record, bring the top of the unit to about 10 cm (4 inches) from your mouth and speak clearly but not too loudly. The way the record function starts depends on the application program and cannot be described here. ·
To play back, the internal speaker should be strong enough to listen the information at the distance from which you normally do your keyboard entry. In a noisy environment, it could be necessary to bring the top of the unit nearer to your ear. The way the play back function starts depends on the application program and cannot be described here.
·
You can increase or decrease the volume by pressing + (plus) or (minus) during playback of messages.
·
For optimal performance, do not cover the speaker and microphone with any type of material. Both parts are already sealed against water and dust with a special membrane. They require no additional protection.
_MAN33-A (CMU027-A7)
Page 38
26
_MAN33-A (CMU027-A7)
Page 39
27
MAINTENANCE AND STORAGE The PC9800 is a reliable instrument and requires little maintenance. Only occasional replacements of the battery and strap are required. It is important not to leave the PC9800 exposed to the sun for long periods of time, since the airtight casing may accumulate sufficient heat to cause a malfunction. NOTE:
There are no user serviceable parts inside the PC9800. Do not try to open the case. Any attempt to do so may affect the weatherproofing and may damage the unit, as well as void the warranty.
Cleaning Use a normal soft cloth and mild soap to clean the PC9800. Do not use abrasives, as they may damage the finish. Make certain that the battery compartment and PC Card door are correctly closed before starting the cleaning operation.
Transporting When transporting the unit, it is a good idea to use the protective case available from DAP TECHNOLOGIES (part number BW800).
Shipping the unit The PC9800 has been designed to resist the vibration and shock that can occur during normal use of the product. However, if it is necessary to ship the PC9800 any long distance, the handling involved in land and air transport can often subject the PC9800 to impact beyond that for which it was designed to withstand. It is therefore essential that the PC9800 be properly packed in an adequate and appropriate manner before being shipped. The packing box that DAP TECHNOLOGIES uses for shipping the PC9800 to its customers was designed for this very purpose, and should, therefore, be set aside and kept, in case reshipping becomes necessary.
Storing If the unit is not going to be used for few days you can just keep it on the charger. For a storage period of a few weeks, fully recharge the PC9800, turns it off and store the unit at a temperature from 20°C (68°F) to 25°C (77°F). This procedure can be used for a storage period shorter than four (4) weeks for a PC9800 with SRAM memory and two (2) weeks for a PC9800 with DRAM memory. Within that time range, your data will be preserved on the disk. After the specified period you need to fully recharge the unit if you wish to continue the storing for another period. This to preserve the battery specification as per the manufacturer directives. Keeping the unit continuously on the charger is also possible but will affect the battery capacity in the time. This could affect applications where very long battery life is required but shows no problem if the unit is normally recharged daily.
_MAN33-A (CMU027-A7)
Page 40
28 DAP recommends that the user do a calibration of the Power Gauge Mechanism (see “Power Gauge Mechanism”).
Battery maintenance The high quality Lithium-Ion battery installed by DAP in your PC9800 can be recharged over 500 times. If you find that the batteries are not lasting for the normal period (at least 12 hours) after having been recharged, it may be time to change them. When used under normal conditions, the battery should last, on average, from 24 to 36 months.
Backup battery maintenance The PC9800 backup battery allows you to keep programs and data in the PC9800 memory for years without being replaced. Being rechargeable, and protected against deep discharge, the backup battery will not need to be replaced during the expected lifetime of the PC9800.
Carrying strap maintenance The carrying strap requires no specific maintenance. Use a normal soft cloth and mild soap to clean it. It may be necessary to replace it from time to time, due to wear.
List of user replaceable parts There are few parts that the user can easily replace. The following list shows parts that need to be replaced occasionally as they deteriorate with use. Part Number DC800 DC801 FIGURE 13 User’s replaceable parts
_MAN33-A (CMU027-A7)
Description Lithium-Ion Battery Carrying strap (4 per package)
Page 41
29
TROUBLESHOOTING CHART Summary of the Battery Status Indicator COLOR Red, continuous Green, continuous Red, blinking Yellow, continuous
MEANING Charger connected, unit is charging Charger connected, unit fully charged User’s defined low battery warning Charger detected but the battery temperature is too high or too low to be recharged. Charging will start when temperature will be adequate. Power from the charger not detected
Turned off FIGURE 14 Meaning of the Battery Status Indicator
Basic troubleshooting Problems
Possible causes and solutions
The screen is empty and the keyboard does not beep when pressing a key. The unit does not turn on when pressing the F1 key.
The unit is possibly turned off. Press the F1 key to restart it. (Refer to item “Turning the unit on). Batteries are possibly too low. Connect the unit to a charger. The unit should wake up after a few seconds and display the battery low message. Refer to section “BATTERY AND CHARGING”) When connected to a charger, the Battery status Indicator should turn red. Otherwise, check to be sure that the modular charger is connected to the wall outlet. Remove the battery. If the unit restarts, the battery needs to be replaced by a new one. Reset the unit. Refer to “Resetting the unit”. The PC Card is possibly inserted the wrong way. Refer to “USE OF PC CARD”.
The unit does not restart by itself when connected to a charger.
The PC Card does not connect in the PCMCIA socket. Display contrast is weak The display contrast is incorrectly set. Use the or display background contrast keys to adjust the display. Refer to very dark “Display background and contrast, additional adjustments” The display cannot be adjusted correctly if the unit is used outside of its temperature limits
_MAN33-A (CMU027-A7)
Page 42
30
Problems
Possible causes and solutions
The unit does not power off automatically or manually. FIGURE 15 Troubleshooting chart
The unit is possibly connected to a charger, or, the application program has possibly disabled the automatic power off feature.
There are some specific situations that can cause the PC9800 program to crash or behave strangely. The more common causes are as listed below. Programming errors, specifically when trying a new application program. Missing or corrupted programs or data files. Operation of the unit outside the specified temperature range. Physical abuse. In such an instance, the physical cause will be observable by doing a survey of the unit, looking for plastic cracks or corrosion marks in the battery and PC Card compartments. In all of these cases, contact your supervisor or the application program supplier. If the problem cannot be resolved, contact the equipment supplier or DAP TECHNOLOGIES. A reset of the unit may correct the problem, or it may be necessary to return the unit to the Service Center.
_MAN33-A (CMU027-A7)
Page 43
31
OPERATING ENVIRONMENT Operating Temperature The recommended temperature range where the PC9800 may be used is from -20°C to +50°C (-4°F to +122°F). A short exposure to temperatures lower or higher than these could possibly make the screen very dark or light until the unit returns within the suggested temperature range. Long exposure to temperatures below -40°C (-40°F) may damage the screen. Prolonged exposure to temperatures above +60°C (+140°F) will damage the main battery and above +70°C may damage the unit (+158°F).
Rain And Water Resistance The PC9800will withstand exposure to rain without the ingress of water. It is designed to withstand occasional immersions. The unit floats, making it easy to retrieve when dropped in water. These characteristics can be impaired if the battery compartment or the PC-Card doors are improperly closed or if their gaskets have deteriorated.
Resistance To Shock The PC9800is designed to withstand shock and accidental drops from up to two meters (six feet) onto a hard surface within the fully specified temperature range. The PC9800LS is designed to withstand shock and accidental drops from up to one meter (three feet) onto a hard surface within the fully specified temperature range. It is obvious that these situations should be avoided as much as possible.
Electromagnetic Resistance The PC9800 work perfectly well in most common environments involving electromagnetic fields such as when near power transmission lines, electric motors, transformers, compressors, low power RF transmitters, etc. Performance can be degraded when using a communication cable, a peripheral or a battery charger under these conditions.
_MAN33-A (CMU027-A7)
Page 44
32
_MAN33-A (CMU027-A7)
Page 45
33
ADVANCED USERS INFORMATION
The following sections contain information that is for advanced users and supervisors. The information is not a requirement for adequate use of the PC9800.
For all information concerning the download of the communication program (COM.EXE), the battery manager (BATMNGR.EXE), the DOS files and some utilities that can be used on PC9800 Series units, please refer to the extranet web site of DAP Technologies (DocuDAP: https: https://support.daptech.com.)
Where to find more information. Start your Internet browser and go to the following address: http://support.daptech.com Login using your Username and Password and click LOGIN Then go under section « Product Documentation / User Guides & Updates / Other Downloads »
_MAN33-A (CMU027-A7)