The text of a manual · part 4 of 7
PC9800 & PC9800LS User's Guide, pages 28 to 36
Pages 28 to 36 of 62
The original document is the PDF (555 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the DAP PC9800
Page 28
16
_MAN33-A (CMU027-A7)
Page 29
17
SCREEN DESCRIPTION The PC9800 normally displays 25 lines of 25 characters. The application program can also configure it to display many other types of fonts. The most current ones are: · 25 lines of 33 characters · 16 lines of 25 characters · 12 lines of 25 characters The PC9800 screen can display upper and lower case letters as well as graphics. It is automatically temperature compensated to give you a clear and contrasted reading at very low or very high temperatures. An additional manual adjustment is possible for extreme low, or extreme high, temperature.
Back lighted screen and keyboard To use the unit in a low light environment, every PC9800 is equipped with a backlighted screen. Optionally, the PC9800 can also be equipped with a backlighted keyboard. Note:
Backlighting can drain batteries rapidly if used constantly. Only use it when necessary, in a low light environment. To active the backlighting of the screen and keyboard, press the blue key, and then the F3 key. The same sequence will deactivate this feature. Backlighting normally turns off by itself after 45 seconds if there is no key pressed or new information on the screen. The backlighted keyboard has 2 distinct zones: · The numeric section, or top keyboard section, which includes the Function key row down to the Enter key row. · The alpha section, or bottom keyboard section, which includes the A, B, C, D row down to the W, X, Y, Z row. Normally, both zones of the keyboard will be backlighted but, under software control, only one zone, or no zone at all, can be backlighted.
Display background and contrast, additional adjustments The PC9800 includes a precise automatic temperature compensation system to assure you that the screen display contrast will be at its best in any circumstance. In extreme temperatures, outside of the -20 to +50°C (-4 to +122°F) range, or simply to adjust it to your preference, you may have to manually readjust it. In extreme low temperatures, pressing the blue key, and then the F5 key one after the other can increase the display contrast. You can hold down the F5 key to take advantage of the keyboard repeat function and go quickly from one step to another.
_MAN33-A (CMU027-A7)
Page 30
18 In extreme high temperatures, pressing the blue key, and then the F4 key one after the other can reduce the display background darkness. You can hold down the F4 key to take advantage of the keyboard repeat function and go quickly from one step to another. There are about 16 steps to each contrast limit, starting from the default adjustment.
_MAN33-A (CMU027-A7)
Page 31
19
USE OF PC CARDS To insert, remove or swap a PC Card, follow the steps described below. You can refer to FIGURE 3 and FIGURE 10 to locate the mentioned items. NOTE:
It is preferable to insert, remove or replace a PC Card in a clean, dry area. Make sure that neither water nor dust will enter the PC9800. Release button slot 0 Release button slot 1 (PC9800 only)
Watertight Gasket
FIGURE 10 PC Card compartment
1. It is normally not necessary to turn off the PC9800 before inserting, removing or swapping a PC Card. This can be done any time while the unit is running or turned off. It is possible that the PC Card used, or the application program, does not allow an insertion while the unit is running. Your supervisor, the application program supplier or DAP TECHNOLOGIES are the best sources to contact in order to answer this question.
2. Using a small, flat blade, screw driver, remove the PC Card access door by loosening the 2 screws located on the top side of the PC9800 (FIGURE 3), about 2 turns to the left (counterclockwise). Slowly pull out the door (FIGURE 10). A flexible strap will keep the PC Card door attached to the right side of the casing. In like manner the screws have a special mechanism to retain them in the cover.
3. To remove the actual PC Card, if present, press the appropriate release button located on the left side of the card. The card will exit the socket by a few millimeters. It is preferable to use a finger as a protection, to stop the exit of the card. Complete the removal by pulling out the card with your hand.
4. To insert a PC Card, slide it in the socket (the end with the 2 rows of little holes first and the manufacturer label on top). When the sliding begins to be a bit tight, push the card firmly. The release button should pop out and the card should hold firmly in the socket. If this is not so, the card is _MAN33-A (CMU027-A7)
Page 32
20 possibly upside down. Before closing the door, check the plastic gasket located around the internal side of the casing (see figure). It should be in good condition, perfectly clean, with no dust, sand, grease, oil or other impurities. Any fault in this aspect could cause the PC Card door to leak and eventually damage the unit.
5. To close the door, slowly replace the door in its initial position. Assure yourself that the card does not exceed the casing and touch the door. Tighten the 2 screws (FIGURE 3), about 2 turns to the right (clockwise). Tighten them until you feel some resistance. Do not over tighten the screws. The application program should run normally after these steps. It is possible that the card or the application program may require that the PC9800 be reset.
Resetting the unit Holding the keys F1, 9 and 0 pressed together for about 2 seconds, does reset of the unit. The following display (see FIGURE 11) should appear for a few seconds, after which the application program will restart or the DOS prompt will appear, depending on the way the unit has been programmed. NOTE:
The reset should never be done without authorization from your supervisor or special directive since, under certain circumstances, data loss can occur.
DAP Technologies == MICROFLEX PC9800 == Version 1.00 <special message> Total Memory: xx MB System Memory: xxxx Kb Extended Memory: xx Mb FIGURE 11 Initialization message
PC card overload While inserting a PC card into a slot the message of FIGURE 12 might appear. This can indicate that the card is not compatible with the PC9800 or the card has a problem or simply that the card requires a high rush current when starting. Remove and re-insert the card a few times to see if the problem always appears. In that case refer to your supervisor or material supplier.
DAP Technologies === MICROFLEX PC9800 === ** WARNING ** PCMCIA OVERLOAD
_MAN33-A (CMU027-A7)
FIGURE 12 PC card overload message
Page 33
21
IrDA INTERFACE The PC9800 comes with an optical port on its bottom side. Its main purpose is to be used with the cradle to communicate. In addition, the same Optical Port integrates an IrDA interface. See Figure A2 and A3 of the User’s Guide to locate the IrDA interface. An IrDA interface is an advanced technology that allows Infra Red communication with peripherals and between computers. On a PC9800, the main purpose of an IrDA Interface is to communicate with a printer, without any cable attachment. Communication with another computer or even another PC9800 is also possible. The way the printing is done using IrDA is mainly dependent of the application program. It is then impossible to describe here precisely how it will handle it. You should refer to your application program user’s guide for complete details. In the mean time, the following presents the basic information. ·
To communicate with the IrDA interface, the peripheral or the remote computer should also have an interface supporting the IrDA protocol.
·
To communicate with the peripheral, point the bottom side of the PC9800 at the IrDA receptor on the peripheral. Usually the receptor looks like a dark plastic window about 17x7 mm (3/4x5/16 inch). Stay aligned within about ±15°
·
The communication can be done from a distance of up to 1 meter (3 feet).
·
The communication link is strong enough to withstand a quite large displacement between the computer and the peripheral. In case of bad reception, the communication protocol will restart the transmission of the missed data block.
·
Direct, strong sunlight can degrade the communication link, increasing the communication duration or even causing a breaking of the link. Under direct sunlight, protect the PC9800 and the peripheral with the shade of your body and keep the PC9800 closer to the peripheral.
NOTE:
As an option, the PC9800 can have a second IrDA interface on the top of the unit (see FIGURE 3). That interface functions exactly as the one explained above. The IrDA interface on the top of the unit can be advantageous in pointing to a peripheral in front of the user, such as a peripheral attached to a wall. This also allows for any required keyboard entry just prior to the IrDA communication session.
Printing with IrDA The main purpose of the IrDA interface is to support printing without using a cable attachment. Printing using IrDA needs to be supported by your application program. If it is the case with your program, you just need to direct the PC9800’s IrDA port toward the printer’s IrDA port when it is time to print. You may refer to the section above for more information. The PC9800 will make 2 short beeps to indicate that the printer has been detected and that the printing starts. You will have several seconds to establish the optical link before the PC9800 returns an error to the application program.
_MAN33-A (CMU027-A7)
Page 34
22 After hearing these 2 first beeps, try to keep your position until you hear a second set of 2 beeps, telling you that the transfer of information to the printer is completed. From there, you can continue your normal activity. The printer may continue to print for several seconds after the second set of beeps. This is normal. It is caused by data still remaining into the printer buffer. If the optical link is broken before data transfer from the PC9800 to the printer is completed, you will hear several long beeps telling you to reestablish the optical link. You will normally have plenty of time to reestablish the link without any loss of information. The PC9800 will emit up to 20 beeps before stopping the print. However, the printer may stop to print by itself before the PC9800 does. In both case, you may have to re-print your document.
_MAN33-A (CMU027-A7)
Page 35
23
BARCODE LASER SCANNER (optional, PC9800LS) The PC9800LS is a standard PC9800 on which a Laser Barcode Reader has been installed in place of the optional IrDA 2 interface. The behavior of the Laser Barcode Reader is mainly under the control of an application program and a special software driver. It is then impossible to describe here precisely how they will handle it. You should refer to your application program user’s guide for complete details. In the meantime, the following presents the basic information. ·
Point the top of the PC9800LS toward the barcode label to read.
·
Press the F3 <SCAN> key and move the PC9800LS back and forth to assure you that the beam will completely cross the label. 2 good ways to scan a label
2 bad ways to scan a label
·
You will hear a short beep when the label will be decoded.
·
You can release the F3 <SCAN> key at any time to stop the scanning.
·
If you keep the F3 <SCAN> pressed for too long the scanning will stop by itself after a certain time. You will hear 2 beeps meaning that no barcode has been decoded.
Refer to the PC9800 & PC9800LS Technical Guide and Development Tools manual for more information about the use and the programming.
CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Do not intentionally look at the laser light
_MAN33-A (CMU027-A7)
Page 36
24
Maintenance Notice The efficiency of the reading depends of the quality of this plastic window. TAKE PARTICULAR CARES OF IT · Any scratch, dirt or finger mark will degrade the reading quality. · To clean up used soft cloth with soap and water. Any plastic lens cleaner will also do the job.
_MAN33-A (CMU027-A7)