The text of a manual · part 3 of 7
PC9800 & PC9800LS User's Guide, pages 19 to 27
Pages 19 to 27 of 62
The original document is the PDF (555 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the DAP PC9800
Page 19
7
BATTERY AND CHARGING The PC9800 is powered by a rechargeable (Lithium-Ion) battery. The battery allows three workdays of autonomous operation.
Battery power monitoring At any time supervisors and advanced users can get information about the battery level from the SETUP program. Refer to sections “THE SETUP PROGRAM” in the ADVANCED part of this manual
The PC9800 includes a Power Gauge allowing you to monitor the power remaining in the battery at any time. Your application program may be developed to display to you that information. You should refer to your application program User’s Guide to check if that feature is supported. When implemented, the Power Gauge also needs to be calibrated prior to use, and then from time to time, to keep its precision. Advanced users can refer to section “POWER GAUGE CALIBRATION” in the ADVANCED part of this manual. The PC9800 also has a Battery Status Indicator, located on the bottom right corner of the unit (see FIGURE 2). This indicator starts to blink in a red color when power begins to be low. The level at which the Battery Status Indicator starts to blink can be modified. It is then possible to adjust the time from which the blinking starts to a complete shut off of the unit. Advanced users can refer to section “THE SETUP PROGRAM” in the ADVANCED part of this manual. Note:
the Battery Status Indicator may blink only when the Power Gauge is calibrated.
The PC9800 uses a specifically designed and tested main battery to insure quick charging time, long-battery life and to withstand shocks and vibrations. To be sure that the battery is conform for usage on a DAP equipment, buy them directly from DAP TECHNOLOGIES or one of its distributors (Part number DC800) and check for the DAP label on it. Batteries that are not from DAP Technologies, even if they come from the same manufacturer and look the same, can have incorrect recharge, give a lower charge and battery life, show improper behavior of "Low Bat" message and break when dropped.
_MAN33-A (CMU027-A7)
Page 20
8
The low battery message When the battery level is low, the unit turns off automatically. When you resume your application program, whether you have recharged the batteries or not, the unit displays a message. This message says that the unit shut down automatically because the battery was low, and that the battery should be recharged if you have not already done so (see FIGURE 5). The message will be cleared after a few seconds, and the unit will return to your application program until the next time you have a low battery message.
DAP Technologies === MICROFLEX PC9800 === ** WARNING ** A low battery level has been detected Battery needs to be recharged or replaced if not done yet. FIGURE 5 Low battery messages The unit may refuse to turn back on because the battery is too low. In that case, the message will appear when you connect the PC9800 to a charger. The PC9800 is equipped with a backup battery. This battery insures that the application program, data and files are always saved, even when the battery is too low or when it is being replaced. See “The backup battery” for more details.
Recharging the battery The PC9800 is normally ordered with a charging kit. A choice of several charging kits is available. The first two, part number AS800 or AS802, allow charging the PC9800 from the LEMO type connector. The second two, part number AS820 or AS822, allow charging from a communication cradle. The specific kit required depends on the type of power available for the charger: · The AS800, AS820, for charging from a 110 V, 50-60 HZ source · The AS802, AS822, for charging from a 220 V, 50-60 HZ source The charging operation is completed within three hours. The PC9800 intelligent charging system will stop by itself when the battery is completely recharged.
_MAN33-A (CMU027-A7)
Page 21
9 === IMPORTANT === The recharging must be done when the battery is at a temperature between 0°C (32°F) and 45°C (113°F), this to preserve the battery integrity. The Battery Status Indicator goes yellow if the battery is too hot or to cold to be charged and the charging system is disabled.
From the LEMO connector
Round connector (insert and tighten)
** Dimensions and cable length are not to scale.
Align red dots then insert
Communication connector
FIGURE 6 FROM A LEMO CABLE The installation requires the modular charger and the communication cable from the LEMO Connector Charging Kit (part number AS800 or AS802). Insert the round connector of the modular charger into the round connector of the small cable attached to the communication cable’s 9-pin connector (FIGURE 6). Connect the modular charger to the wall outlet. Align the red dot located on the LEMO connector end of the cable with the red dot found on the round connector located on the right side of the PC9800 and insert connectors, one into the other. Note:
If your PC9800 has 2 round connectors (LEMO connector), use the top one. The PC9800’s Battery Status Indicator (FIGURE 2), will turn red in the next 5 seconds, indicating that charging is in progress and will become green when the full charge is completed. This could take up to 3 hours. If the unit was turned off, it should turn back on after a few seconds. Processing will resume exactly where it was interrupted once recharging starts.
_MAN33-A (CMU027-A7)
Page 22
10 Communication cradle The installation requires the modular charger and the communication cradle from the Cradle Charging Kit (part number AS810, AS812, AS820 or AS822). Before charging the PC9800, you first need to power the communication cradle. Insert the round connector of the modular charger into the round connector at the top left of the cradle (FIGURE 7). Connect the modular charger to the wall outlet. From there, to recharge the PC9800 battery, you just need to slide the PC9800 into the cradle, bottom first.
FIGURE 7 Charging from a communication cradle The PC9800’s Battery Status Indicator (FIGURE 2) will turn red in the next 5 seconds, indicating that charging is in progress and will become green when the full charge is completed. This could take up to 3 hours. If the unit was turned off, it should turn back on after a few seconds. Processing will resume exactly where it was interrupted once recharging starts.
Replacing the battery It is preferable to replace the batteries while in a clean, dry area. Make sure that neither water nor dust can enter the PC9800. NOTE:
Always turn off the PC9800 before replacing the batteries. The backup batteries will retain your data and programs.
IMPORTANT: Removing the battery while the unit is still turned-on may result in a loss of data and a booting of the unit when the battery is re-installed. You will also lose your calibration of the battery
_MAN33-A (CMU027-A7)
Page 23
11 The PC9800 uses a specifically designed battery to assure a quick charging time and long battery life. Consequently, this is only available from DAP TECHNOLOGIES or one of its distributors. Order part number DC800. Replacement of the battery is an easy task. Follow the steps outlined below.
Battery cover
Simply insert the battery, this side first
CHECK FOR THE ARROW
FIGURE 8 Battery compartment ·
Turn off the unit first (see section “Turning the unit OFF manually”)
·
Using a small, flat blade, screwdriver, remove the 4 screws marked “Release screws for battery compartment” in FIGURE 3.
·
Pull out the battery and insert the new one, inserting the left side first. Be sure to align the arrow on the battery, toward the right, as shown on FIGURE 8. The foam (not shown on the drawing) should go over the battery, to make it tight in the casing.
·
Re-install the 4 screws, and tighten them until you feel some resistance.
·
Turn the unit back on and charge the battery if required.
The PC9800 uses a specifically designed and tested main battery to insure quick charging time, long-battery life and to withstand shocks and vibrations. To be sure that the battery is conform for usage on a DAP equipment, buy them directly from DAP TECHNOLOGIES or one of its distributors (Part number DC800) and check for the DAP label on it. Batteries that are not from DAP Technologies, even if they come from the same manufacturer and look the same, can have incorrect recharge, give a lower charge and battery life, show improper behavior of "Low Bat" message and break when dropped.
_MAN33-A (CMU027-A7)
Page 24
12
The backup battery The main battery recharges the backup battery that preserves the memory. The backup battery is recharged from the main battery even if the unit is not charging. The backup battery life depends of the type of memory used and the quantity. Battery life is typically7 days with 16Mb of DRAM and over a month with SRAM memory. The backup battery capacity decrease greatly at temperature below 20°C.
The PC9800 backup battery allows you to keep programs and files in the PC9800 memory for days. In practice, the backup battery is used only while you replace the battery, when the battery is absent or when the battery is very low. Even if the battery is too low to power the PC9800, enough energy remains to power the memory for weeks, without using the backup battery. The backup battery will be switched on to maintain the memory only when the battery is completely dead. A low backup battery message is displayed if the backup battery is low when the unit reboot (see FIGURE 9 ).
DAP Technologies === MICROFLEX PC9800 === ** WARNING ** BATTERY BACKUP Backup battery is very low. Refer to User's Guide. You may have to reinstall your program to assure integrity. FIGURE 9 Low Backup Battery message The backup battery is rechargeable. “MAINTENANCE AND STORING”.
_MAN33-A (CMU027-A7)
See item
“Storing” under
Page 25
13
KEYBOARD DESCRIPTION Use of the keyboard The PC9800 keyboard is the unit’s command center. To make the PC9800 easy to handle and simultaneously make the keys big enough, the PC9800 has been equipped with 51 keys. However, these 51 keys are sufficient for all your command entry needs.
Direct access keys Letters, digits, function keys and an escape key are examples of direct access keys. To generate this type of character, simply press the key bearing the desired character.
Multi-key entry Sometimes you might need to press more than one key to get a character or a special function. The SHIFT (é), CTL/ALT or blue key are the keys that can precede a letter or a digit to modify its original value. According to your preferences, or as the situation demands, you can decide to use one of the two following methods to form the sequence of keys.: Press the keys one after the other, releasing the previous key before pressing the next. This method (also known as one finger typing) allows you to use only one finger to make any function Or You can press all of the keys required together, using two or more fingers. The color code simplifies the way the keyboard works. The blue key needs to be pressed first to get a character in blue. A simple way to understand how the multi-key entry works is by typing a ?. The ? being in blue means that you must precede it with the blue key which is also in blue. You may use either method described above.
Auto-repeat A key will automatically start to repeat if left pressed for more than one second. It will stop repeating when you release it.
Description of the important keys Digit and letter keys To generate a character, either as an alpha (letter) or numeric (digit) value, simply press the key bearing the desired letter or digit. Letters are normally all in upper case.
Lower case once To generate a lower case letter, press the following keys: the SHIFT (é), followed by the desired letter.
_MAN33-A (CMU027-A7)
Page 26
14
Continuous lower case To generate a series of lower case letters, first press the blue key then the “0” (zero). This will simulate the Caps Lock key you find on a conventional PC keyboard.
Upper case once To generate a single upper case character, press the SHIFT (é) followed by the desired letter.
Continuous upper case To return to upper case characters, just repeat the blue key then the “0” (zero).
Enter key or Return key
The bent arrow (↵) is used to accept an entry. The key corresponds to a RETURN or ENTER key on an ordinary keyboard. This is the key normally used to complete a typed command.
Space The SPACE key corresponds to the space bar of a normal keyboard.
Keys for punctuation and special symbols To enter punctuation marks, or special typographic symbols, press the blue key and then the letter key marked with the desired symbol in blue. To generate a ?, press the blue key, and then V.
Editing keys (Del, Backspace) Editing keys, (i.e., the keys used to correct typographical errors) are simple to use: a key marked with BKSP corresponds to the backspace function. This key will erase the last character typed. To erase the character in the current position, press the blue key and then DEL.
Cursor pad The cursor pad groups together four arrow keys, also called direction keys or cursor keys. It is mainly used in an application to make a selection of data, to select and start a function within a menu or to move the cursor on a line to edit the characters. On the cursor pad, press the extremity of the cross representing the appropriate direction: up, down, left, or right.
_MAN33-A (CMU027-A7)
Page 27
15
Minus (-) and Plus (+) signs The “-“ enters a minus sign in the application. It is frequently used to enter a negative quantity. To generate a minus sign, press the key marked + . To generate a plus sign, press the blue key and +.
Dot sign (.) The “.” key enters a dot in the application. It is frequently used to enter a decimal quantity.
ESC The ESC key is generally used to stop an action or return to a previous menu. It is mainly application dependent.
Function keys (F1…F10) The function keys are for direct access to a specific function in your application. Function keys F1 to F5 are direct access. The function keys (F6 to F10) are obtained on the PC9800 by pressing SHIFT (é) followed by a number from F1 to F5. You need to refer to your Application User’s Guide to know the intended meaning of these keys, in your specific user application. NOTICE: on the PC9800LS the F3 <SCAN> key is generally used to start a barcode scan and consequently will not generate a F3 function key. See the Security Notice for the PC9800LS at the beginning of the page..
ON/OFF switch To turn on the PC9800, simply press the F1 key. To turn off the PC9800, press the blue key and F1 key.
Other special keys Other key combinations are possible and reserved for particular PC9800 operations. For more information, refer to the section “ADVANCED KEYBOARD FUNCTIONS” in this manual.
_MAN33-A (CMU027-A7)