The text of a manual · part 6 of 7
PC9800 & PC9800LS User's Guide, pages 46 to 54
Pages 46 to 54 of 62
The original document is the PDF (555 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the DAP PC9800
Page 46
34
_MAN33-A (CMU027-A7)
Page 47
35
ADVANCED KEYBOARD FUNCTIONS -- INFORMATION -The following information is for advanced users and its knowledge is not a requirement for adequate use of the PC9800.
The keyboard of your MICROFLEX PC9800 gives you access to the most common keys you can find on a standard desktop computer. In addition, it includes several keys specific to the unit. Not all keys have the same significance or use. That is why several keys or key sequences have not been described previously, but are supported as hidden keys on the keyboard.
FUNCTION
KEY or KEY SEQUENCE
Position and Editing keys INS HOME END PAGE UP PAGE DOWN
BLUE KEY + INS BLUE KEY + 7 BLUE KEY + 1 BLUE KEY + 9 BLUE KEY + 3
TABULATION BACK TABULATION
BLUE KEY + 4 BLUE KEY + 6
CTRL HOME CTRL END CTRL PAGE UP CTRL PAGE DOWN
BLUE KEY + CTL + BLUE KEY + 7 BLUE KEY + CTL + BLUE KEY + 1 BLUE KEY + CTL + BLUE KEY + 9 BLUE KEY + 3
CAPS LOCK
BLUE KEY + 0
To stop processing or quit current operation ESCAPE CONTROL-C
ESC BLUE KEY + CTL + C
To print ECHO ON PRINTER PRINT SCREEN
BLUE KEY + CTL + P BLUE KEY + 5
To generate special characters OUTPUT ASCII CODE
ALT and 3 digits (require the Alternate Keyboard map)
For function keys F1 to F5 F6 to F10 CTRL-F1 to CTRL-F5 CTRL-F6 to CTRL-F10
Direct access SHIFT + F1 to F5 BLUE KEY + CTRL + F1 to F5 BLUE KEY + CTRL + SHIFT + F1 to F5
Manual window scrolling movement WINDOW UP BLUE KEY + Up Arrow WINDOW DOWN BLUE KEY + Dn Arrow WINDOW LEFT BLUE KEY + Left Arrow WINDOW RIGHT BLUE KEY + Right Arrow FIGURE 16 List of keyboard-hidden keys
_MAN33-A (CMU027-A7)
Page 48
36
_MAN33-A (CMU027-A7)
Page 49
37
POWER GAUGE CALIBRATION NOTE BATMNGR.EXE REQUIRES A BIOS VERSION 1.07 OR HIGHER
This chapter describes the use of BATMNGR.EXE version 1.40. BATMNGR.EXE is the program used to calibrate and test the PC9800 battery capacity. When calibrated, the SETUP menu POWER MANAGEMENT (see FIGURE 17) gives you an accurate value of the remaining battery capacity. The Battery Status Indicator will also flash when the battery will reach the Battery Warning Level sets by the user (see section THE SETUP PROGRAM, under “Warning Level”). When a full battery test is performed the calibration of the battery is also done but an indication of the maximum capacity of the battery is also given. When compared to previous values it allows you to decide whether to perform a preventive replacement of the battery. Calibration of the battery is suggested · Every time the POWER MANAGEMENT menu of the SETUP program displays that the LAST CALIBRATION is expired. · Every time the main battery is removed SETUP Ver 1.xx POWER MANAGEMENT -------+ POWER OFF DELAY =xxxx BATTERY WARNING LEVEL = xx%
-- BATTERY STATUS -ACTUAL LEVEL
= xx%
LAST CALIBRATION DATE = xxxx/xx/xx STATUS = VALID --------<MAIN MENU>
Remaining power Date of the last calibration (comes from the log file created by BATMNGR.EXE Calibration status VALID/EXPIRED
+-----------------------PRESS ENTER TO MODIFY tu TO SELECT NEXT ITEM FIGURE 17 The Power Management menus NOTE:
A non-calibrated battery DOES not affect the battery life nor the charging duration. The calibration only allows the PC9800 to accurately report the remaining capacity of the battery and to enable the battery Status Indicator to blink when the battery reaches the Warning Level. A PC9800 can be freely used with a non-calibrated battery. _MAN33-A (CMU027-A7)
Page 50
38
Installation of BATMNGR BATMNGR runs on the PC9800. You may find the BATMNGR.EXE program file under sub-directory TOOLS on the PC 9800’s Companion Disk 1, revision 5 and higher. In that last case you just need to transfer the file BATMNGR.EXE to the PC9800. Release 1.40 of BATMNGR runs only on a PC 9800.
NOTE •
BATMNGR.EXE requires a BIOS version 1.07 or higher
•
Release 1.40 of BATMNGR runs only on a PC 9800.
•
BATMNGR.EXE is not on your PC9800 by default. It needs to be transferred form the Companion Disk (see above)
Calibration mode To start BATMNGR in Calibration mode at the DOS prompt (A>) enter the following command: BATMNGR F [ENTER] When started for a Battery Test mode, the first operation of BATMNGR is to fully charge the PC9800 battery, so as to start the test from a known point. Then, it starts a deep discharge operation and a second full recharge operation. The full battery test could last up to 17 hours depending on the initial charge level of the battery and their actual state (fresh batteries vs. used ones).
Quick Calibration Since the Calibration Mode could take up to 17 hours it could be useful to sometime have a way to make it faster. The Quick calibration does about the same than the Calibration Mode but leaves the PC9800 discharged at the end of the cycle. To start BATMNGR in Quick Calibration at the DOS prompt (A>) enter the following command: BATMNGR D [ENTER] When started for a Quick Calibration the program charges the battery then discharge the battery until a low battery warning occurs. At this point, BATMNGR re-connects the charger and quits. Calibration of a PC9800 could last up to 13 hours. At the end of the cycle, the unit is not charged but is ready for any other task while it completes the charging.
Aborting the operation At any time, you can abort the operation by entering the character "@" on the PC9800 keyboard. This is done by first pressing the Blue key, and then the "I" key.
_MAN33-A (CMU027-A7)
Page 51
39
Status display While running, the BATMNGR program displays the following information (FIGURE 18). BATTERY MANAGER V1.40 DATE:
1998/07/22
TIME:
14:46:43
Charge #1:
000 min.
Discharge: 0000 min. Remaining Discharge Time:
0000 min.
Charge #2:
000 min.
Capacity:
0000 mA/h
Status: Charging
FIGURE 18 Status display NOTE:
Program version
Current date and time Duration of the first charge Discharge duration
Duration of the second charge (Battery Test mode only) Total battery capacity (Battery Test mode only) Status line
The battery charger needs to be present when you start BATMNGR. If the PC9800 charger is not connected an error message will be displayed on the 2 last lines of the screen.
_MAN33-A (CMU027-A7)
Page 52
40
Typical results As a guideline, a fresh battery should give the typical following values. The previous readings done with the same battery also need to be compared to be able to know the actual battery capacity and tendency. First charge Discharge Second charge** Capacity **
Minimum value Non-relevant 450 min. 150 min. 1200 ma-h
Typical value Non-relevant 475-700 min. 175-250 min. ~1800 ma-h
** Calibration Mode only, not indicated in Quick Calibration FIGURE 19 BATMNGR typical values If values are far from the typical values it is suggested to: · Check LAST CALIBRATION into the SETUP program. It should be VALID with the ACTUAL LEVEL between 100 and 140% · Run another BATMNGR If the battery still refuses to calibrate, · Turn-off the PC9800 · Remove the battery for about a minute · Re-install the battery then run BATMNGR again If it still remains non-calibrated, · Replace the battery · Call DAP Technologies Customer Support
_MAN33-A (CMU027-A7)
Page 53
41
THE SETUP PROGRAM -- INFORMATION – The following information is for advanced users and its knowledge is not a requirement for an adequate use of the PC9800. It is possible that the application program restricts your access to the SETUP program.
--- WARNING --The modification of the configuration parameters may affect the correct behavior of your application program. Be sure you proceed with all the required knowledge and authorization.
The user can modify some characteristics of the PC9800. When the unit is inactive for several seconds, for example, the screen turns off in order to save battery power. The user can modify the delay after which the screen blanks out, or can modify this characteristic so that the screen is always on. This can be done easily using the SETUP program. The program SETUP allows you to display and modify the parameters that determined the characteristics of the PC9800. Among other things, the program allows you to control: The power-off delay The display time-out The display font The scrolling mode And to visualize The actual battery level and the date of the last battery calibration The hardware configuration The date and time The parameters are stored in the PC9800’s Configuration Variables. They are specific memory locations, protected from being written by any type of application programs. They are preserved even when the PC9800 is turned off or reset. When you use the SETUP program to modify the values of parameters, the new values becomes effective only when you quit the program using the UPDATE AND SAVE option. Note:
This information reflects version 1.06 of the SETUP.EXE program
Using the program Starting the program The program SETUP is started from DOS. Before starting the program, you should see the DOS prompt (e.g. “A>” or “C>”) on the screen of the PC9800. Enter the following command: C:\SETUP <ENTER>
_MAN33-A (CMU027-A7)
Page 54
42 Once started, the program SETUP displays the main menu. SETUP Ver 1.06 MAIN --------------------+ SET DATE: xxx/xx/xxxx SET TIME: xxx:xx:xx …….……………… SCREEN TIME OUT= xxxx ACTIVE FONT = x SCROLLING = xx …….……………… KEY CLICK = xxx …….……………… POWER MANAGEMENT... HARDWARE INFO... …….……………… <UPDATE AND EXIT> <EXIT WITHOUT UPDATE> +-----------------------PRESS ENTER TO MODIFY tu TO SELECT NEXT ITEM FIGURE 20 Main menu
Using the menus
-- NOTE -The bottom line will start to blink showing you that you are in EDIT mode.
The menus of SETUP were designed to make the program friendly and easy to use. The name and the version always appear on the first line. The last 2 lines specify the required action to do. Below the name of the menu, there is a list of options. To select an option, you may navigate using the Down Arrow or Up Arrow located on the cursor pad until the desired item is highlighted. To enter the EDIT mode and adjust the parameters value, you press ENTER. To edit the value, with some options you have to use the Left Arrow and Right Arrow key, located on the cursor pad, to increase or decrease the value. With some others, you have to enter directly the value from the numeric pad. Again, the last 2 lines are useful to inform you of the next action and the accepted range of values. At any time you can press ESC to quit the EDIT mode and return to the NAVIGATION mode, preserving the previous value. Some options are an entry to another menu. They are terminated with 3 dots (... ), as with POWER MANAGEMENT... . Pressing ENTER will display the sub-menu. The ESC key will return to the parent menu.
Quitting the program Selecting the option UPDATE AND SAVE makes the new parameters effective by updating the PC9800 Configuration Variables, quits the program and returns to DOS. Selecting EXIT WITHOUT UPDATE will preserve your previous values Note:
_MAN33-A (CMU027-A7)
The DATE and TIME are changed as you modify them into the field.