Page 352
Appendix B - Cabling, Hardware, & Electrical Cable #5: Cyclades/Sun Netra Cable This Adapter attaches to a Cat 3 or Cat 5 network cable. It is usually used in console management applications to connect Cyclades products to a Sun Netra server or to a Cisco product. This cable is included in Cable Package #2.
Figure 41: Cable 5 - Cyclades/Sun Netra Cable
Adapters The following four adapters are included in the product box. A general diagram is provided below and then a detailed description is included for each adapter.
Loop-Back Connector for Hardware Test The use of the following DB-25 connector is explained in the Troubleshooting chapter. It is included in both Cable Package #1 and #2.
TxD RxD RTS CTS DSR DCD DTR Figure 42: Loop-Back Connector
352
Cyclades-TS
Page 353
Appendix B - Cabling, Hardware, & Electrical Cyclades\Sun Netra Adapter This Adapter attaches to a Cat 3 or Cat 5 network cable. It is usually used in console management applications to connect Cyclades products to a Sun Netra server or to a Cisco product. At one end of the adapter is the black CAT.5e Inline Coupler box with a female RJ-45 terminus, from which a 3-inch-long black Sun Netra-labeled cord extends, terminating in an RJ-45 male connector. This adapter is included in Cable Package #2.
Figure 43: Cyclades\Sun Netra Adapter
RJ-45 Female to DB-25 Male Adapter The following adapter may be necessary. It is included in Cable Package #1. RJ-45
DB-25M
Figure 44: RJ-45 Female to DB-25 Male Adapter
User Guide
353
Page 354
Appendix B - Cabling, Hardware, & Electrical RJ-45 Female to DB-25 Female Adapter The following adapter may be necessary. It is included in Cable Package #1.
Figure 45: RJ-45 Female to DB-25 Female Adapter
RJ-45 Female to DB-9 Female Adapter The following adapter may be necessary. This is included in Cable Package #1. RJ-45
DB-9F
Figure 46: RJ-45 Female to DB-9 Female Adapter
354
Cyclades-TS
Page 355
Appendix B - Cabling, Hardware, & Electrical TS110/100-only Cabling Information The RS-485 Standard The RS-485 is another standard for serial communication and is available only in the TS110/ 100. Different from the RS-232, the RS-485 uses fewer wires - either two wires (one twisted pair) for half duplex communication or four wires (two twisted pairs) for full duplex communication. Another RS-485 characteristic is the “termination.” In a network that uses the RS-485 standard, the equipment is connected one to the other in a cascade arrangement. A “termination” is required from the last equipment to set the end of this network.
TS110/100 Connectors Although the RS-485 can be provided in different kinds of connectors, the Secure Console Port Server SSH 1-Port uses a 9-pin D-shaped connector (DB-9) and a Terminal Block with the pin assignment described below.
Table 35: TS110/100 Connector pin assignment RS-485 Signal
Name/Function
PW+
DB-9 pins
Terminal Block pins
Not in use
1
TXD-
Transmit Data - (A)
7
2
TXD+
Transmit Data + (B)
3
3
RXD+
Receive Data + (B)
2
4
RXD-
Receive Data - (A)
8
5
Not in use
6
PW-
User Guide
355
Page 356
Appendix B - Cabling, Hardware, & Electrical TS110 Current Specifications Analog Ports - 100mA monetary 10mA continuous 90uA minimum
Digital Ports - Outputs - 10mA maximum 3.6 mA minimum Inputs - 8.3 mA maximum 3.6mA minimum
Figure 47: Terminal Block Pins Notice that if the TS110/100 is configured to use RS-485, the RS-485 signals will be available in both DB-9 and Terminal Block. In this case, the DB-9 pins used in an RS-232 connection can be considered not connected.
356
Cyclades-TS
Page 357
Appendix B - Cabling, Hardware, & Electrical Cable Diagrams Cable #1: DB-9 Female to DB-9 Female, crossover half duplex Application: It connects the TS110/100 (serial port) DTE RS-485 devices with half duplex communication.
Figure 48: Cable 1 for the TS110/100 - DB-9 Female to DB-9 Female, crossover half duplex
Cable #2: DB-9 Female to DB-9 Female, crossover full duplex Application: It connects the TS110/100 (serial port) to DTE RS-485 devices with full duplex communication.
Figure 49: Cable 2 for the TS110/100 - DB-9 Female to DB-9 Female, crossover full duplex
User Guide
357
Page 358
Appendix B - Cabling, Hardware, & Electrical Cable #3: Terminal Block to Terminal Block, crossover half duplex Application: It connects the TS110/100 (serial port) to DTE RS-485 devices with half duplex communication.
Terminal Block
Terminal Block
Figure 50: Cable 2 for the TS110/100 - Terminal Block to Terminal Block, crossover half duplex
Cable #4: Terminal Block to Terminal Block, crossover full duplex Application: It connects the TS110/100 (serial port) to DTE RS-485 devices with full duplex communication.
Terminal Block
Terminal Block
Figure 51: Cable 4 for the TS110/100 - Terminal Block to Terminal Block, crossover full duplex
358
Cyclades-TS
Page 359
Appendix B - Cabling, Hardware, & Electrical Cable #5: DB-9 Female to DB-25 Female, crossover This cable connects the TS110/100 to console ports, terminals, printers and other DTE RS232 devices. You will essentially have the cable shown in this picture:
DB DB9
DB25
Figure 52: Cable 5 for the TS110/100 - DB-9 Female to DB-25 Female, crossover
User Guide
359
Page 360
Appendix B - Cabling, Hardware, & Electrical
This page has been left intentionally blank.
360
Cyclades-TS