Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 36 of 49

Cyclades-TS User Guide: Appendix B - Cabling, Hardware, and Electrical Specifications, pages 343 to 351

Pages 343 to 351 of 454, from Cyclades-TS User Guide

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cyclades TS2000 and Avocent TS2000

Page 343

Appendix B - Cabling, Hardware, & Electrical General Hardware Specifications

Appendix B - Cabling, Hardware, and Electrical Specifications

The power consumption and heat dissipation, environmental conditions and physical specifications of the Cyclades-TS are listed below.

Table 23: Cyclades-TS power requirements Power Specifications TS110/100

TS400

TS800

TS1000

TS2000

TS3000

Input Voltage Range

External Universal Input Desktop Power Supply, 100240VAC auto-range input, 5VDC output (Internal power modules available for 12VDC, 24VDC, -48VDC and Power Over Ethernet)

External Universal Input Desktop Power Supply (100-240VAC auto-range input, 5VDC output)

External Universal Input Desktop Power Supply (100-240VAC auto-range input, 5VDC output)

Internal 100240VAC autorange (-48VDC option available)

Internal 100240VAC autorange (-48VDC option available)

Internal 100240VAC autorange

Input Frequenc y Range

50/60H

50/60H

50/60H

50/60H

50/60H

50/60H

Power @120VAC

5 W max

5 W max

6 W max

22 W max

26 W max

11 W max

Power @220 VAC

6 W max

6 W max

8 W max

28 W max

37 W max

17 W max

User Guide

343

Page 344

Appendix B - Cabling, Hardware, & Electrical Table 25: Cyclades-TS environmental conditions Environmental Information TS110/ 100

TS400

TS800

Operating Temperature

50F to 122F

50F to 112F

50F to 112F

(10 C to

(10 C to

(10 C to 44 C)

(10 C to 44 C)

Relative Humidity

10 - 90%, non-

10 - 90%, noncondensing

10 - 90%, noncondensing

10 - 90%, noncondensing

º 50ºC)

º 44ºC)

condensing

º

TS1000 50F to 112F

º

º

º

TS2000

TS3000

50F to 112F

50F to 112F

º 44ºC)

º

º

(10 C to

(10 C to 44 C)

10 - 90%, noncondensing

10 - 90%, noncondensing

Table 28: Cyclades-TS physical specifications Physical Information TS100

TS110

TS400

TS800

TS1000

TS2000

TS3000

External Dimensions

2.76 x 3.35 x 1.18 in.

3.4 x 4.8 x 1 in.

8.5 x 4.75 x 1 in.

8.5 x 4.75 x 1 in.

17 x 8.5 x 1.75 in.

17 x 8.5 x 1.75 in.

17 x 8.5 x 1.75 in.

Weight

0.3 lb.

0.8 lb.

1.5 lb.

1.6 lb.

6 lb.

6.2 lb.

8 lb.

TS2000

TS3000

Table 31: Cyclades-TS safety specifications Safety Information TS110/ 100 Approvals

344

TS400

TS800

TS1000

FCC and CE, Class A

Cyclades-TS

Page 345

Appendix B - Cabling, Hardware, & Electrical The following section has all the information you need to quickly and successfully purchase or build cables to the Cyclades-TS. It focuses on information related to the RS-232 interface, which applies not only to the Cyclades-TS but also to any RS-232 cabling. At the end of this chapter you will also find some information about the RS-485 interface, which is available for the Cyclades-TS110/100 models only.

The RS-232 Standard RS-232C, EIA RS-232, or simply RS-232 refer to a standard defined by the Electronic Industries Association in 1969 for serial communication. More than 30 years later, more applications have been found for this standard than its creators could have imagined. Almost all electronic devices nowadays have serial communication ports. RS-232 was defined to connect Data Terminal Equipment, (DTE, usually a computer or terminal) to Data Communication Equipment (DCE, usually a modem): DTE > RS-232 > DCE > communication line > DCE > RS-232 > DTE RS-232 is now mostly being used to connect DTE devices directly (without modems or communication lines in between). While that was not the original intention, it is possible with some wiring tricks. The relevant signals (or wires) in a RS-232 cable, from the standpoint of the computer (DTE), are: Receive Data (RxD) and Transmit Data (TxD)

The actual data signals

Signal Ground (Gnd)

Electrical reference for both ends

Data Terminal Ready (DTR)

Indicates that the computer (DTE) is active

Data Set Ready (DSR)

Indicates that the modem (DCE) is active.

Data Carrier Ready (DCD)

Indicates that the connection over the communication line is active

CTS (Clear to Send, an input)

Flow control for data flowing from DTE to DCE

RTS (Request to Send, an output)

Flow control for data flowing from DCE to DTE

User Guide

345

Page 346

Appendix B - Cabling, Hardware, & Electrical Not all signals are necessary for every application, so the RS-232 cable may not need all 7 wires. The RS-232 interface defines communication parameters such as parity, number of bits per character, number of stop-bits and the baud rate. Both sides must be configured with the same parameters. That is the first thing to verify if you think you have the correct cable and things still do not work. The most common configuration is 8N1 (8 bits of data per character, no parity bit included with the data, 1 stop-bit to indicate the end of a character). The baud rate in a RS-232 line translates directly into the data speed in bits per second (bps). Usual transmission speeds range between 9,600 bps and 19,200bps (used in most automation and console applications) to 115,200 bps (used by the fastest modems).

Cable Length The original RS-232 specifications were defined to work at a maximum speed of 19,200 bps over distances up to 15 meters (or about 50 feet). That was 30 years ago. Today, RS-232 interfaces can drive signals faster and through longer cables. As a general rule, consider: •

If the speed is lower than 38.4 kbps, you are safe with any cable up to 30 meters (100 feet)

•

If the speed is 38.4 kbps or higher, cables should be shorter than 10 meters (30 feet)

•

If your application is outside the above limits (high speed, long distances), you will need better quality (low impedance, low-capacitance) cables.

Successful RS-232 data transmission depends on many variables that are specific to each environment. The general rules above are empirical and have a lot of safety margins built-in.

346

Cyclades-TS

Page 347

Appendix B - Cabling, Hardware, & Electrical Connectors The connector traditionally used with RS-232 is the 25-pin D-shaped connector (DB-25). Most analog modems and most older computers and serial equipment use this connector. The RS232 interface on DB-25 connector always uses the same standard pin assignment. The 9-pin D-shaped connector (DB-9) saves some space and is also used for RS-232. Most new PC COM ports and serial equipment (specially when compact size is important) uses this connector. RS-232 interfaces on DB-9 connectors always use the same standard pin assignment. The telephone-type modular RJ-45 plug and jack are very compact, inexpensive and compatible with the phone and Ethernet wiring systems present in most buildings and data centers. Most networking equipment and new servers use RJ-45 connectors for serial communication. Unfortunately there is no standard RS-232 pin assignment for RJ-45 connectors. Every equipment vendor has its own pin assignment. Most connectors have two versions. The ones with pins are said to be “male” and the ones with holes are said to be “female.” Table 32: Cables and their pin specifications RS-232 Signal

Name/Function (Input/Output)

DB-25 pins (Standard)

DB-9 pins (Standard)

RJ-45 pins (Cyclades)

Chassis

Safety Ground

1

Shell

Shell

TxD

Transmit Data (O)

2

3

3

RxD

Receive Data (I)

3

2

6

DTR

Data Terminal Ready (O)

20

4

2

DSR

Data Set Ready (I)

6

6

8

DCD

Data Carrier Detect (I)

8

1

7

RTS

Request To Send (O)

4

7

1

CTS

Clear To Send (I)

5

8

5

Gnd

Signal Ground

7

5

4

User Guide

347

Page 348

Appendix B - Cabling, Hardware, & Electrical Straight-Through vs. Crossover Cables The RS-232 interface was originally intended to connect a DTE (computer, printer and other serial devices) to a DCE (modem) using a straight-through cable (all signals on one side connecting to the corresponding signals on the other side one-to-one). By using some “cabling tricks,” we can use RS-232 to connect two DTEs as is the case in most modern applications. A crossover (a.k.a. null-modem) cable is used to connect two DTEs directly, without modems or communication lines in between. The data signals between the two sides are transmitted and received and there are many variations on how the other control signals are wired. A “complete” crossover cable would connect TxD with RxD, DTR with DCD/DSR, and RTS with CTS on both sides. A “simplified” crossover cable would cross TxD and RxD and locally short-circuit DTR with DCD/DSR and RTS with CTS.

Which cable should be used? First, look up the proper cable for your application in the table below. Next, purchase standard off-the-shelf cables from a computer store or cable vendor. For custom cables, refer to the cable diagrams to build your own cables or order them from Cyclades or a cable vendor. Table 33: Which cable to use To Connect To DCE DB-25 Female (standard) •

Analog Modems

•

ISDN Terminal Adapters

348

Use Cable Cable 1: RJ-45 to DB-25 M straight-through (Custom). This custom cable can be ordered from Cyclades or other cable vendors. A sample is included with the product (“straight-through”).

Cyclades-TS

Page 349

Appendix B - Cabling, Hardware, & Electrical Table 33: Which cable to use To Connect To DTE RJ-45 Cyclades (custom) •

All Cyclades Console Ports

DTE DB-25 to DB-9 Cyclades (custom) •

For the Cyclades-TS110/100

Use Cable Cable 2: RJ-45 to RJ-45 crossover (custom). A sample is included with the product (“straight-through”) This custom cable can be ordered from Cyclades or other cable vendors using the provided wiring diagram. Cable 3: DB-9 Female to DB-25 Female crossover. This connects the Cyclades-TS110/100 (serial port) to terminals, printers and other DTE RS-232 devices.

Cable Diagrams Before using the following cable diagrams refer to the tables above to select the correct cable for your application. Sometimes, crossover cables are wired slightly differently depending on the application. A “complete” crossover cable would connect the TxD with RxD, DTR with DCD/DSR, and RTS with CTS across both sides. A “simplified” crossover cable would cross TxD and RxD and locally short-circuit DTR with DCD/DSR and RTS with CTS. Most of the diagrams in this document show the “complete” version of the crossover cables, with support for modem control signals and hardware flow control. Applications that do not require such features have just to configure NO hardware flow control and NO DCD detection on their side. Both ends should have the same configuration for better use of the complete version of the cables. These cables appear in Cable Package #1 and/or Cable Package #2. You may or may not find them in your box depending on which package you received.

User Guide

349

Page 350

Appendix B - Cabling, Hardware, & Electrical Cable #1: Cyclades RJ-45 to DB-25 Male, straight-through Application: This cable connects Cyclades products (serial ports) to modems and other DCE RS-232 devices. It is included in both Cable Package #1 and #2.

Figure 37: Cable 1 - Cyclades RJ-45 to DB-25 Male, straight-through

Cable #2: Cyclades RJ-45 to DB-25 Female/Male, crossover This cable connects Cyclades products (serial ports) to console ports, terminals, printers and other DTE RS-232 devices. If you are using Cable Package #1, after connecting the appropriate adapter to the RJ-45 straight-through cable, you will essentially have the cable shown in this picture. If you are using Cable Package #2, no assembly is required. You will have the cable shown below.

Figure 38: Cable 2 - Cyclades RJ-45 to DB-25 Female/Male, crossover

350

Cyclades-TS

Page 351

Appendix B - Cabling, Hardware, & Electrical Cable #3: Cyclades RJ-45 to DB-9 Female, crossover This cable connects Cyclades products (serial ports) to console ports, terminals, printers and other DTE RS-232 devices. If you are using Cable Package #1, after connecting the appropriate adapter to the RJ-45 straight-through cable, you will essentially have the cable shown in this picture. If you are using Cable Package #2, no assembly is required. You will have the cable shown below.

Figure 39: Cable 3 - Cyclades RJ-45 to DB-9 Female, crossover

Cable #4: Cyclades RJ-45 to Cyclades RJ-45, straight-through This cable is the main cable that you will use. Along with one of the adapters provided (RJ-45 to DB-9 or RJ-45 to DB-25) you can create a crossover cable like the ones explained in Cable #2 or #3 for configuration or to connect to a server. This cable is only included in Cable Package. #1. RJ-45 Male

RJ-45 Male

Figure 40: Cable 4 - Cyclades RJ-45 to Cyclades RJ-45, straight-through

User Guide

351