Page 9

TurboWedge Menus Industrial Code Selections - b Enter Industrial Code Selections

Default Industrial Code Selections

Scan Selection CODE 93

CODE 128

MSI / PLESSEY

Bar Code

Exit Industrial Code Selections

Program Code

Variables

H6

Enable Minimum Length Maximum Length

A B

*ON / OFF *00 – 64 00 – 64*

Enable Minimum Length Maximum Length

A B

*ON / OFF *00 – 64 00 – 64*

Enable Minimum Length Maximum Length

A B

*ON / OFF *04 – 64 04 – 64*

H7

H8

Page 9

* = Default

TurboWedge Menus

09/06/02

Page 10

TurboWedge Menus Retail Code Selections SELECTIONS Enter Retail Code Selections Default Retail Code Selections

Scan Selection

Bar Code

Exit Retail Code Selections

Program Code

Variables

UPC`

I1

UPC-A UPC-E 2 Digit Addendum (1) 5 Digit Addendum (1) Check Digit Transmit Number System Transmit Zero Suppression

A C D E F G H

*ON / OFF *ON / OFF *ON / OFF *ON / OFF *ON / OFF *ON / OFF *ON / OFF

EAN

I2

EAN/JAN 8 EAN/JAN 13 2 Digit Addendum (2) 5 Digit Addendum (2)

A B C D

*ON / OFF *ON / OFF *ON / OFF *ON / OFF

(1) (2)

Also programs corresponding EAN variables Also programs corresponding UPC variables

RETAIL CODE OUTPUT FORMAT Output Format Non-Zero Suppressed UPC-A and UPC-E

Output Format Zero Suppressed UPC-A and UPC-E

UPC-A UPC-A with 2 digit addendum UPC-A with 5 digit addendum UPC-E UPC-E with 2 digit addendum UPC-E with 5 digit addendum

UPC-A UPC-A with 2 digit addendum UPC-A with 5 digit addendum UPC-E UPC-E with 2 digit addendum UPC-E with 5 digit addendum

NXXXXXXXXXXC NXXXXXXXXXXC-AA NXXXXXXXXXXC-AAAAA NXXXXXXXXXXC NXXXXXXXXXXC-AA NXXXXXXXXXXC-AAAAA

NXXXXXXXXXXC NXXXXXXXXXXC-AA NXXXXXXXXXXC-AAAAA NXXXXXXC NXXXXXXC-AA NXXXXXXC-AAAAA

Output Format Non-Zero Suppressed UPC-A and UPC-E EAN/JAN 13 EAN/JAN 13 with 2 digit addendum EAN/JAN 13 with 5 digit addendum EAN/JAN 8 EAN/JAN 8 with 2 digit addendum EAN/JAN 8 with 5 digit addendum

FNXXXXXXXXXXC FNXXXXXXXXXXC-AA FNXXXXXXXXXXC-AAAAA FNXXXXXXC FNXXXXXXC-AA FNXXXXXXC-AAAAA

Page 10

* = Default

TurboWedge Menus

09/06/02

Page 11

TurboWedge Menus Edit Selections Enter Edit Selections

Exit Edit Selections

Default Edit Selections Scan Selection

Program Code

Edit Number

J1

Variables

Secondary Output

01 – 99 ON

Port

J2

Scanner Auxiliary Magnetics ALL

1 2 3 4

Symbology

J3

Codabar Code 3 of 9 UPC-A EAN Interleaved 2 of 5 Code 2 of 5 Code 11 Code 93 Code 128 Plessey ALL / Magnetics

A B C D E F H I J 2 G

Input Record Length

J4

00-64

Fields in Input Record Input Field Length Function Codes ASCII Data = 1 Only Match Data = ON

J5 J6 J7

01-31 00 – 64 00 – FE

Additional Fields

J8

00 – 15

J9 JA

01 – 15 00 – FE

JB

01 - 64

Additonal Field Length Additional Field Data ASCII Data = 15 max Output Sequence Input Field Numbers Added Field Numbers

Page 11

* = Default

TurboWedge Menus

09/06/02

Page 12

TurboWedge Menus Keyboard Re-Mapping Enter KeyMap Selections

Exit KeyMap Selections

Default KeyMap Selections Scan Selection

Bar Code

Variables

SINGLE CHARACTER REPLACEMENT

ASCII Character to be replaced Depress Key on Keyboard

01 – FE

SWAP TWO CHARACTERS

1- Depress First Key on Keyboard 2 -Depress Second Key on Keyboard (Re-Enter for another Swap)

SWAP TWO ASCII CHARACTERS

First ASCII Character to Swap Second ASCII Character to Swap (Re-Enter for another Swap)

01 – FE 01 – FE

MULTIPLE KEY FUNCTION RECORD

ASCII of Function Record 1- Depress Keys on Keyboard 2- Scan DISPLAY to Verify 3- Scan STORE if Correct If not correct – Scan REDO or EXIT

16 – FE

DISPLAY / STORE

REDO

Page 12

* = Default

TurboWedge Menus

09/06/02

Page 13

TurboWedge Menus Status Check Enter Status Check Selections

Exit Status Check Selections

Scan Selection

Bar Code

Variables

TO TERMINAL

L1

General / Auxiliary Selections Bar Code Configuration Edit Parameters (1) Keyboard Re-Map

A B C D

TO AUXILIARY PORT

L2

General / Auxiliary Selections Bar Code Configuration Edit Parameters

A B C

NOTE: (1) (2)

TurboWedge 2 Only Scanning the EXIT symbol is not required if one of the above selections is scanned.

Page 13

* = Default

TurboWedge Menus

09/06/02

Page 14

TurboWedge Menus Program Mode

Bar Code

Variables

DEFAULT ALL

BEGIN ON-SCREEN PROGRAMMING MODE

WINCAPE ENABLE

CLONE IN

CLONE OUT

BAR CODE LEARN

PROGRAM LOCK

Page 14

* = Default

TurboWedge Menus

09/06/02

Page 15

TurboWedge Menus NOTE: The bar codes on this page correspond to symbols on adjoining menu pages. SCAN these bar codes in the sequence indicated to program desired selections and variables

Bar Codes For Menus

ALPHA

DIGITS

OTHERS

A

0

ON

B

1

C

2

D

3

E

4

F

5

G

6

H

7

I

8

J

9

OFF

Page 15

* = Default

TurboWedge Menus

09/06/02