For the Compsee Turbo-Wedge

Page 1

TurboWedge Menus

TurboWedge Menus

Page 1

* = Default

TurboWedge Menus

09/06/02

Page 2

TurboWedge Menus Terminal Selection

Enter Terminal Selection

Default = 01 PC/AT

Exit Terminal Selection

To determine the correct Terminal ID Number reference the TurboWedge Genealogy Chart.

Page 2

* = Default

TurboWedge Menus

09/06/02

Page 3

TurboWedge Menus General Selections - I Selection Enter General I Selections Default General I Selections Scan Selection

Bar Code

Exit General I Selections Program Code

Variables

BEEPER VOLUME

B1

Off = 0 Max = 7

0 – 7*

INPUT INHIBIT CHECK

B2

Enable If enabled, may require the installation of a clip lead inside the terminal

ON / OFF*

KEYBOARD TYPE

B3

Primary Secondary -

A* B

INTERCHARACTER DELAY

B4

X 10 milliseconds

*00-99

INTERFUNCTION DELAY

B5

X 10 milliseconds

*00-99

NUMERIC KEYPAD

B7

Enable

ON / OFF*

Page 3

* = Default

TurboWedge Menus

09/06/02

Page 4

TurboWedge Menus General Selections - II Enter General II Selections Default General II Selections

Scan Selection AUXILIARY PORT INPUT

Bar Code

Exit General II Selections

Program Code

Variables

C1

RS 232 MSR Input Track 1 Track 2 Track 3 Tracks 1 & 2 Tracks 2 & 3 Tracks 1 & 3 Tracks 1, 2 & 3 Any Valid Track

0

TurboWedge 1 = Port 2 TurboWedge 2 = Port 3

1 2* 3 4 5 6 7 8

BUFFERING

C2

Enable

ON / OFF*

SCALE SOLICIT RECORD

C3

ASCII Characters 4 max

00 – FE * none

SWITCHES

C4

Output Edited Records Only MSR Reverse Turbo Mode HP, WYSE & PC/AT IBM PC/AT – w/o Keyboard Laser with Marker Beam Laser with AutoSense

SET PAUSE TIME

C5

X 100 milliseconds

1 2 3 4

ON / OFF* ON / OFF* ON / OFF* ON / OFF*

5 6 7 8

ON / OFF* ON / OFF* ON / OFF* ON / OFF* *00-99

Page 4

* = Default

TurboWedge Menus

09/06/02

Page 5

TurboWedge Menus Scanner Port Selections Enter Scanner Port Selections Default Scanner Port Selections Scan Selection

Bar Code

Exit Scanner Port Selections Program Code

Variables

PREAMBLE

D1

ASCII Characters 16 max (1)

00 – FE * none

POSTAMBLE

D2

ASCII Characters 16 max (1)

00 – FE * none

LASER REDUNDANCY

D3

Enable

ON / OFF*

FUNCTION CODES

D4

Enable

ON / OFF*

CODE IDENTIFICATION

D5

Enable

ON / OFF*

AUTOSCAN

D6

Detect Rate X 100 milliseconds

*00 – 99

MULTISCAN

D7

Time Between Reads X 10 milliseconds

A

*00 – 99

Same Bar Code Read

B

ON / OFF*

(1)

Note – Preamble & Postamble To delete preambles or postambles scan the Selection followed by another selection or EXIT

Page 5

* = Default

TurboWedge Menus

09/06/02

Page 6

TurboWedge Menus Serial Selections – I Enter Serial I Selections Default Serial I Selections Scan Selection

Bar Code

Exit Serial I Selections Program Code

Variables

PREAMBLE

E1

ASCII Characters 16 max (1)

00 – FE * none

POSTAMBLE

E2

ASCII Characters 16 max (1)

00 – FE * none

RECORD TERMINATOR

E3

ASCII Characters one only

00 – FE* *0D

FUNCTION CODES

E4

Enable

ON / OFF*

(1)

Note – Preamble & Postamble To delete preambles or postambles scan the Selection followed by another selection or EXIT

Page 6

* = Default

TurboWedge Menus

09/06/02

Page 7

TurboWedge Menus Serial Selections - II Enter Serial II Selections (1)

Enter Host Port Selections (2) Exit Serial II Selections

Default Serial II Selections Scan Selection

Bar Code

Program Code

Variables

BAUD RATE

F1 G1

300 600 1200 2400 4800 9600 19200

A B C D E F* G

PARITY

F2 G2

Mark Space Even Odd None

A B C* D E

WORD LENGTH

F3 G3

7 data bits 8 data bits

A* B

STOP BITS

F4 G4

1 stop bit 2 stop bits

A* B

DUAL / SINGLE RS 232 FLOW CONTROL

F5 G5

None XON / XOFF RTS / CTS

A* B C

RS 232 INPUT PROTOCOL

F6 G6

Record Solicit Burst ACK / NAK Xmodem

A* B C D E

(1) Enter AUX Port Selections TurboWedge 1 = All Serial II Selections TurboWedge 2 = Data Input through Input Port 2

(2) Enter Host Port Selections TurboWedge 1 = Not a valid entry TurboWedge 2 = Data Output Selections Port 2

Page 7

* = Default

TurboWedge Menus

09/06/02

Page 8

TurboWedge Menus Industrial Code Selections - a Enter Industrial Code Selections

Default Industrial Code Selections Scan Selection CODABAR

CODE 3 of 9

CODE I 2 of 5

CODE 2 of 5

CODE 11

Bar Code

Exit Industrial Code Selections

Program Code

Variables

H1

Enable Minimum Length Maximum Length Start / Stop Transmit Concatenate

A B C D

*ON / OFF *00 – 64 00 – 64* ON / OFF* ON / OFF*

Enable Minimum Length Maximum Length Start / Stop Transmit Full ASCII Check Digit Check Digit Transmit Append

A B C D E R G

*ON / OFF *00 – 64 00 – 64* ON / OFF* *ON / OFF ON / OFF* ON / OFF* ON / OFF*

Enable Minimum Length Maximum Length 6 or 14 Digits Only Check Digit Check Digit Transmit

A B C D E

*ON / OFF *04 – 64 04 – 64* ON / OFF* ON / OFF* ON / OFF*

Enable Minimum Length Maximum Length

A B

*ON / OFF *00 – 64 00 – 64*

Enable Minimum Length Maximum Length One Check Digit Two Check Digits

A B C D

H2

H3

H4

H5

*ON / OFF *00 – 64 00 – 64* *

Page 8

* = Default

TurboWedge Menus

09/06/02