Page 31
Apex PDT Technical Reference Manual
3 Hardware Configuration
Latin-1 Character Set Note:
The first 128 Latin-1 characters are the same as in the Standard ASCII Character set and are therefore not shown.
Table 3-5: Extended Latin-1 Character Set
COAM30002
Rev. 2.00
8/13/02
3-11
Page 32
Apex PDT Technical Reference Manual
3 Hardware Configuration
Keyboard The following table lists the keyboard codes used in the Apex Portable Data Collection Terminal. A number within parentheses shown in the table denotes a note. Notes are listed after the last page of the table. Key <1> <2> <3> <4> <5> <6> <7> <8> <9> <.> <0> <SPACE> <A> <B> <C> <D> <E> <F> <G> <H> <I> <J> <K> <L> <M> <N> <O> <P> <Q> <R> <S> <T> <U> <V> <W> <X> <Y> <Z> <DEL> <BKSP> <ENT> (left) <ENT> (right) <SCAN>
Normal 1 2 3 4 5 6 7 8 9 . 0 <space> a b c d e f g h I j k l m n o p q r s t u v w x y z <del> (3) <BKSP> <enter> <enter> (3) <scan> (2)
Shift Ctrl Alt ! (undefined)(5) (4) @ [NULL] (4) # (4) (4) $ (4) (4) % (4) (4) ^ [RS] (4) & (4) (4) * (4) (4) ( (4) (4) > (4) (4) ) (4) (4) <space> <space> <space> A [SOH] (4) B [STX] (4) C [ETX] (4) D [EOT] (4) E [ENQ] (4) F [ACK] (4) G [BEL] (4) H [BKSP] (4) I [HT] (4) J [LF] (4) K [VT] (4) L [FF] (4) M [CR] (4) N [SO] (4) O [SI] (4) P [DLE] (4) Q [DC1](Xon) (4) R [DC2] (4) S [DC3](Xoff) (4) T [DC4] (4) U [NAK] (4) V [SYN] (4) W [ETB] (4) X [CAN] (4) Y [EM] (4) Z [SUB] (4) . (3) (4) (undefined) (5) < BKSP > (ascii)<del> (undefined) (5) <enter> [LF] <alt><enter> <enter> (3) [LF] (3) <alt><enter> (3) <scan> (2) (undefined)(5) (undefined) (5)
Table 3-6: Apex PDT Keyboard Codes
3-12
COAM30002
Rev. 2.00
8/13/02
Fn < _ : , ; | + “ \ = ‘ ~ {battery}(6) {contrast up}(7) {contrast dn}(8) <esc> ` (undefined) (5) (undefined) (5) <tab> <SysReq> {inverse} (9) {backlight}(10) (4) (undefined) (5) / <PrtScrn> ? { } {time/date} (11) <break> (1) {volume}(12) [ ] <pause> (undefined) (5) <ctrl><F8> <insert> (undefined) (5) (undefined) (5) (undefined) (5)
Page 33
Apex PDT Technical Reference Manual
Key <up> <dn> <left> <right> <F1> <F2> <F3> <F4> <SHIFT> <ALT> <CTRL>
Normal <up> (3) <dn> (3) <left> (3) <right> (3) <F1> <F2> <F3> <F4>
Shift 8 (3) 2 (3) 4 (3) 6 (3) <F5> <F6> <F7> <F8>
Ctrl (4) (4) (4) (4) (4) (4) (4) (4)
3 Hardware Configuration
Alt (4) (4) (4) (4) (4) (4) (4) (4)
Fn <page_up> (3) <page_dn> (3) <home> (3) <end> (3) <F9> <F10> <F11> <F12> <capslock> (undefined) (5) (undefined) (5)
Table 3-6: Apex PDT Keyboard Codes (Continued)
Notes: (1) Returns <ctrl><break> to system. (2) <SCAN> returns 62h scan code, normally undefined by DOS (BIOS translates to an extended 38h). (3) Returns the numeric keypad scan codes. (4) Unless otherwise noted, any key + the <SHIFT>, <CTRL>, or <ALT> key generates a scan code identical to the DOS standard definition for that key combination. (5) (undefined) implies that no key code is returned to the BIOS or DOS. (6) {battery} returns 64h (BIOS translates to an extended 3Ah). Displays the remaining battery capacity in a pop-up window if Compsee BIOS extender TSR is loaded. (7) {contrast up} Increases LCD contrast. (8) {contrast dn} Decreases LCD contrast. (9) {inverse} Inverts the video black and white. (10) {backlight} Toggles the display backlight ON/OFF. (11) {time/date} returns 63h (BIOS translates to an extended 39h). Displays the current DOS time and date in a pop-up window if Compsee BIOS extender TSR is loaded. (12) {volume} Adjusts volume level in steps of: OFF, 1, 2, 3, (OFF)… The following keys, found on a standard IBM-PC compatible keyboard, are NOT implemented on the Apex PDT keypad: Right Shift Page Up* Delete* Right Alt Page Down* Up Arrow* Right Ctrl Home* Down Arrow* Num Lock End* Left Arrow* Scroll Lock Insert* Right Arrow* Numeric keypad keys: 0, 1, 3, 5, 7, 9, /, *, -, + *Note: The Numeric keypad counterpart for these keys is implemented on the Apex PDT. Table 3-7: Apex Keypad Compatibility
COAM30002
Rev. 2.00
8/13/02
3-13
Page 34
Apex PDT Technical Reference Manual
3 Hardware Configuration
Apex Specific ROM BIOS Extensions Extension Summary BIOS Interrupt 10h - Video Function No. ah = 11h
Service No. al = 02h al = 04h
Description Set 8 high font Set 15 high font
BIOS Interrupt 15h - System Function No. ah = 55h
Service No. al = 00h al = 01h al = 02h al = 03h al = 04h al = 05h al = 06h al = 07h al = 08h al = 09h al = 0Ah al = 0Bh al = 0Ch al = 0Dh al = 0Eh al = 0Fh al = 10h al = 00h al = 00h
Description Get beeper volume Set beeper volume Volume next Get infrared port state Enable infrared port Get backlight state Set backlight Get video polarity Set video polarity Get screen contrast Set screen contrast Contrast darker Contrast lighter Get default keyclick Set default keyclick Get default typematic delay and repeat rate Set default typematic delay and repeat rate Get gauge BIOS version
BIOS Interrupt 16h - Keyboard Function No. ah = 03h ah = 04h
3-14
Service No. al = 05h
COAM30002
Description Set typematic rate and delay Set keyclick
Rev. 2.00
8/13/02
Page 35
Apex PDT Technical Reference Manual
3 Hardware Configuration
Detailed BIOS Interrupt Information BIOS Interrupt 10h – Video Functions Function 11h, Service 02h – Input: Returns: Notes:
Function 11h, Service 04h – Input: Returns: Notes:
Set 8 High Font ah = 11h al = 02h to set 8 high font Carry Flag clear if successful Carry Flag set on error q This function sets the Apex PDT displayed font height to 8. q Using an 8 high font results in a 20 row display. q The current number of screen rows minus one can be accessed through logical address 0040h:0084h. A value of 19 implies an 8 high font is in use. q Changing the video mode resets the font size; therefore, this function should be called after the video mode has been set.
Set 16 High Font ah = 11h al = 04h to set 16 high font Carry Flag clear if successful Carry Flag set on error q This function sets the Apex PDT displayed font height to 16. q Using an 16 high font results in a 10 row display. q The current number of screen rows minus one can be accessed through logical address 0040h:0084h. A value of 9 implies a 16 high font is in use. q Changing the video mode resets the font size; therefore, this function should be called after the video mode has been set.
COAM30002
Rev. 2.00
8/13/02
3-15
Page 36
Apex PDT Technical Reference Manual
3 Hardware Configuration
BIOS Interrupt 15h - System Function 55h, Service 00h – Input: Returns:
Notes:
ah = 55h al = 00h Carry Flag clear if successful ax = current setting (0 = off, 1 = low, 2 = med, 3 = high) Carry Flag set on error This function retrieves the current volume setting of the Apex PDT internal beeper.
Function 55h, Service 01h – Input:
Returns:
Notes:
Returns:
Notes:
3-16
Set Beeper Volume ah = 55h al = 01h bx = volume setting (0 = off, 1 = low, 2 = med, 3 = high) Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function is used to set the Apex PDT internal beeper volume to the desired level.
Function 55h, Service 02h – Input:
Get Beeper Volume
Volume Next ah = 55h al = 02h Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function increases the Apex PDT internal beeper volume from its current setting to the next higher setting. Volume steps from high (3) to off (0).
COAM30002
Rev. 2.00
8/13/02
Page 37
Apex PDT Technical Reference Manual
Function 55h, Service 03h – Input: Returns:
Notes:
Returns:
Notes:
Returns:
Notes:
Enable Infrared Port ah = 55h al = 04h bx = infrared port state (0 = disable, 1 = enable) Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function is used to select the active Apex PDT serial port. A zero (0) disables the infrared port (enables RS-232 port), whereas a one (1) enables the infrared port (disables the RS-232) for serial transmission. Only one serial device may be enabled at a time.
Function 55h, Service 05h – Input:
Get Infrared Port State ah = 55h al = 03h Carry Flag clear if successful ax = current setting (0 = RS-232, 1 = IR) Carry Flag set on error This function retrieves the current setting of the Apex PDT serial port. A zero (0) indicates the infrared port is disabled (RS-232 port enabled), whereas a one (1) indicates the infrared port is enabled (RS-232 port disabled) for serial transmission.
Function 55h, Service 04h – Input:
3 Hardware Configuration
Get Backlight State ah = 55h al = 05h Carry Flag clear if successful ax = current setting (0 = off, 1 = on) Carry Flag set on error This function retrieves the current state of the Apex PDT Backlight.
COAM30002
Rev. 2.00
8/13/02
3-17
Page 38
Apex PDT Technical Reference Manual
Function 55h, Service 06h – Input:
Returns:
Notes:
Returns:
Notes:
Returns:
Notes:
3-18
Get Video Polarity ah = 55h al = 07h Carry Flag clear if successful ax = current setting (0 = normal, 1 = reversed) Carry Flag set on error This function retrieves the current setting of the Apex PDT video polarity. Normal (black text on a white background) or reversed (white text on a black background) are the returned settings.
Function 55h, Service 08h – Input:
Set Backlight ah = 55h al = 06h bx = backlight state (0 = off, 1 = on) Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function is used to set the state of the Apex PDT Backlight.
Function 55h, Service 07h – Input:
3 Hardware Configuration
Set Video Polarity ah = 55h al = 08h bx = video polarity state (0 = normal, 1 = reversed) Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function is used to set the Apex PDT video polarity. Normal (black text on a white background) or reversed (white text on a black background) are the allowable settings.
COAM30002
Rev. 2.00
8/13/02
Page 39
Apex PDT Technical Reference Manual
Function 55h, Service 09h – Input: Returns:
Notes:
Returns:
Notes:
Returns:
Notes:
Returns:
Notes:
Contrast Darker ah = 55h al = 0Bh Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function increases the Apex PDT Display contrast setting by one step.
Function 55h, Service 0Ch – Input:
Set Screen Contrast ah = 55h al = 0Ah bx = contrast setting (0 to 63) Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function is used to set the Apex PDT Display contrast.
Function 55h, Service 0Bh – Input:
Get Screen Contrast ah = 55h al = 09h Carry Flag clear if successful ax = current setting (0 to 63) Carry Flag set on error This function retrieves the current contrast setting for the Apex PDT Display.
Function 55h, Service 0Ah – Input:
3 Hardware Configuration
Contrast Lighter ah = 55h al = 0Ch Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function decreases the Apex PDT Display contrast setting by one step.
COAM30002
Rev. 2.00
8/13/02
3-19
Page 40
Apex PDT Technical Reference Manual
Function 55h, Service 0Dh – Input: Returns:
Notes:
Returns:
Notes:
Returns:
Notes:
3-20
Set Default Keyclick ah = 55h al = 0Eh bx = keyclick state (0 = off, 1 = on) Carry Flag clear if successful ax = current setting (after change) Carry Flag set on error This function sets the default keyclick state. The default takes affect following a reboot of the unit. This function does NOT set the current keyclick state. Reference Interrupt 16h, Function 04h.
Function 55h, Service 0Fh – Input:
Get Default Keyclick ah = 55h al = 0Dh Carry Flag clear if successful ax = current setting (0 = disabled, 1 = enabled) Carry Flag set on error This function returns the default keyclick state that takes affect following a reboot. This function does NOT return the current keyclick state.
Function 55h, Service 0Eh – Input:
3 Hardware Configuration
Get Default Delay and Repeat Rate ah = 55h al = 0Fh Carry Flag clear if successful Bh = delay value (00h = 250 ms, 01h = 500 ms, 02h = 750 ms, 03h = 1000 ms) Bl = repeat rate (see Function 55h, Service 10h Notes) Carry Flag set on error This function returns the default typematic delay and repeat rate that take affect following a reboot. This function does NOT return the current session settings as set by Interrupt 16h, Function 03h, but rather returns the default settings set by Interrupt 15h, Function 55h, Service 10h.
COAM30002
Rev. 2.00
8/13/02