Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 17

Apex III / Apex IV Technical Reference Manual, Second Edition, pages 141 to 150

Pages 141 to 150 of 168

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Compsee Apex III and Compsee Apex IV

Page 141

Apex PDT Technical Reference Manual

9 Apex PDT Communic ations

SLOT"0"

SLOT"1" RS-232 SERIAL CONNECTOR

PCMCIA CARD SLOT AREA

DIP SWITCHES

Figure 9-2: Internal RS-232 Serial Connector And DIP Switch Locations

Notes: 1. The on-board Apex PDT internal RS-232 Serial Connector is a male 8-pin Molex connector (Molex PN 53261-0890). 2. Serial communication using the RS-232 Serial connection can be half or full duplex. 3. Many types of cables for serial communications with various types of equipment including scales, CCDs, modems, printers, etc. are available from Compsee, Inc. Call the Compsee, Inc. Technical Support Number for additional details.

Communication Procedures The preferred method for file transfer communications with the Apex PDT is to utilize the Apex PDT File Transfer Utility [dx.exe]. Use the following basic procedure to ensure that your file transfers are completed successfully when using this method:

Using The Apex PDT File Transfer Utility 1.

2.

3.

Connect your Apex PDT to the host PC using the Compsee RS-232 Serial Cable (PN 0227001) or by using the Apex III Dock (Apex III PDT only). If NOT already installed, install an approved Communications Application on your PC. (e.g. Compsee, Inc. Windows Transfer Utility, HyperTerminal , P ROCOMMP LUS, etc.). Set the PC Communications application settings to the following: Parameter Transfer Protocol Data Bits Parity Stop Bits Flow Control

COAM30002

Setting YMODEM 8 None 1 None

Rev. 2.00

8/13/02

9-3

Page 142

Apex PDT Technical Reference Manual

9 Apex PDT Communic ations

4.

Verify that the proper communications port on the Apex PDT is enabled for the communications method being utilized (IR port or RS-232 serial port).

5.

On the Apex PDT, set the Apex PDT File Transfer Utility parameters using one of the following methods: Running The Program And Choosing Options From The Command Line: 5.1 Run the File Transfer Utility from the command line (C:\>) by typing “dx” followed by the options you wish to select then pressing <ENT>. Refer to the Utilities section of this manual for additional details. Opening The File Transfer Utility Program And Selecting Options From Within The Program: 5.1 Start the File Transfer Utility by typing “dx” then pressing <ENT> at the prompt (C:\>). “Command?” will appear. 5.2 Choose the optional command from those listed below: Note: Choose the send or receive option last for transfer to occur. Option bn c d i l q r s t v w x ! ? or <F1>

9-4

Description change baud rate, where n is new baud rate. Acceptable rates include 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Default rate is 115200. change directory, note that drive cannot be changed. lists files in local directory specifies IR port usage gets file names from a text file listing (allows multiple file transfers) quiet mode (flip/flop) receive file(s) send file(s) terminal (test) mode (allows Apex PDT screen to display characters typed on the PC) verbose mode use wired RS-232 connection (i.e. Serial End Cap use) exit the program exit after transfer show program settings displays help

COAM30002

Rev. 2.00

8/13/02

Page 143

Apex PDT Technical Reference Manual

9 Apex PDT Communic ations

6.

Choose the operation you wish to perform and select the file(s) you wish to transfer from the PC or Apex PDT (if necessary refer to the HELP files provided with the utility).

7.

Complete the transfer (either sending or receiving).

8.

Verify that the file(s) has/have been transferred properly.

9.

Close the Apex PDT File Transfer Utility by pressing the <FN>+<E> key.

Using The Windows Transfer Utility A Windows Transfer Utility (WXU) for performing file transfers to and from the Apex PDT is included on the Compsee Product Support CD supplied with your unit and also available from our website at www.compsee.com. Refer to the detailed Windows based Help Files incorporated with the Utility for information on how to utilize the utilities features.

Using The [remdisk.exe] Utility Program Notes: Ø To use the remote disk utility [remdisk.exe], both [remdisk.exe] and [remserv.exe] must be running on their respective systems. The baud rate and packet (or non-packet) style transmission mode must be specified the same for both programs. Ø Once both programs have been started, the drive on the client system can be accessed, the default directory changed to the remote drive, files copied and/or moved, and utilities such as [chkdsk.exe] run. The server remote drive can be used as another drive on the client system. Ø Either [remdisk.exe] or [remserv.exe] can be used in a DOS window. If the screen saver starts you will have to press a key or move the mouse to begin again. It is therefore recommended that you disable the screen saver or boot the PC up in the DOS mode to prevent interruptions in transmitting data. Ø While [remserv.exe] will run on a FAT32 system, the drive it makes available to the client cannot be FAT32. Ø PCs running Windows9x are required to use the polling vs. packet transmission mode. Ø [remserv.exe] can be used on the Apex PDT and [remdisk.exe] on the PC. In this case, the Apex PDT drive will become another drive letter on the PC.

COAM30002

Rev. 2.00

8/13/02

9-5

Page 144

Apex PDT Technical Reference Manual

9 Apex PDT Communic ations

Procedure 1. On the Apex PDT, type remdisk /b115- at the DOS prompt C:\>. 2. Note that the /b115- specifies a baud rate of 115,200. Any of the allowable baud rates can be specified here (see the specific details under the Utility Programs section of this manual). 3. On the host PC, type remserv a: /b115- at the DOS prompt C:\>. 4. Note that the /b115- specifies a baud rate of 115,200 to match that specified for use in the [remdisk.exe] program. In the example, the A: drive is specified. 5. The PC drive now appears as the next drive letter on the Apex PDT. The [remdisk.exe] program will specify the drive letter. You can now change to this drive and copy, delete files, etc. as if it were a local drive.

9-6

COAM30002

Rev. 2.00

8/13/02

Page 145

Apex PDT Technical Reference Manual

10

10 Power Management

POWER MANAGEMENT

Power Management within the Apex PDT is accomplished by changing BIOS settings so that power usage is kept to a minimum during normal day to day operations. By minimizing the time that heavy power consuming functions are active, you can prolong the total usage time of the unit during each Battery Pack charge cycle (the time it takes to go from fully charged to fully discharged).

Power State Transitions Within the BIOS Power Management framework are several features that allow you to minimize the Apex PDT’s power consumption. The Apex PDT’s Power saving features are as follows: q q q

Low Speed Timeout Standby Timeout Suspend Timeout

All of these features can be disabled simultaneously or configured separately as the customer requires. When all of the BIOS Power saving features are disabled, the power usage from the Battery Pack will be at its highest level, and the Battery Pack’s charge will dissipate more quickly.

Functional Definitions q

Full On: The system goes through the reset and initialization process and loads the operating system and any other programs called for by the [config.sys] and [autoexec.bat] files. The system is running at 33 MHz, no power management functions are enabled, and all devices are ON.

q

Power Management (PM) Enabled State: The system is in a power saving capacity with some system functions disabled after a specified period of time to conserve system power consumption and Battery Pack drain.

q

High Speed Mode: All parts of the system are clocked at full speed when in the High Speed Mode.

COAM30002

Rev. 2.00

8/13/02

10-1

Page 146

Apex PDT Technical Reference Manual

10 Power Management q

Low Speed Mode: The system enters the Low Speed Mode after a period of inactivity specified by the BIOS Low Speed Timeout setting. If the BIOS Low Speed Timeout is set to OFF, the system will never enter the Low Speed Mode. During the Low Speed Mode the system will perform as follows: Ø The system is functioning at 8 MHz. Ø Power is supplied to the CPU, memory, and available to all peripherals.

q

Standby: The system enters Standby from the Low Speed Mode after a period of inactivity specified by the BIOS Standby Timeout setting. If the BIOS Standby Timeout is set to OFF, the system will never enter Standby. During Standby the system will perform as follows: Ø The system is in a low power state with some power savings. Ø Most power managed devices are in a low power state. Ø The CPU clock is stopped. Ø Operational parameters are saved. Ø A resume event (e.g. key press, power status change) will return the system to the High Speed Mode and to the previous point of operation. Ø Display is turned OFF.

q

Suspend: The system enters Suspend from Standby after a period of inactivity specified by the BIOS Suspend Timeout setting or by the user pressing the <Power> key during normal operation. If the BIOS Suspend Timeout is set to OFF, the system will never enter Suspend. During Suspend the system will perform as follows: Ø The system is in a low power state with maximum power savings. Ø Most power-managed devices are not powered. Ø The CPU clock is stopped and the CPU core is in its minimum power usage state. Ø Operational parameters are saved. Ø A wake-up event (e.g. pressing the Red Power Button) is necessary to return the system to the High Speed Mode and to the previous point of operation.

10-2

COAM30002

Rev. 2.00

8/13/02

Page 147

Apex PDT Technical Reference Manual q

10 Power Management

Critical Suspend: The system enters Critical Suspend following a Battery Critical indication. The system stays in Critical Suspend until an Unlock Event occurs (unit placed in the Dock or changing the Battery Pack). When the unlock event occurs the system returns to the previous point of operation and awakens by pressing the <Power> key.

Note:

DO NOT attempt to operate the Apex PDT once it has powered down due to a low battery condition. When the Battery Pack is exhausted, leave the exhausted Battery Pack in the Apex PDT until you can either charge it in place or swap the Battery Pack with a charged Battery Pack. Information in volatile memory (RAM) will be preserved since the Apex PDT is configured so that even with an exhausted Battery Pack enough energy is retained to maintain the information for an extended period of time. DO NOT leave the unit WITHOUT a Battery Pack for more than 5 minutes.

Using The Power Saving Features 1.

Enter the BIOS Setup and display the Power Setup screen by pressing <F2> during the system boot, then pressing the Right Arrow < > key twice. If the factory default values have NOT been changed the following screen will be displayed:

Figure 10-1: Default BIOS Power Menu Screen

COAM30002

Rev. 2.00

8/13/02

10-3

Page 148

Apex PDT Technical Reference Manual

10 Power Management

2.

To enable any of the Apex PDT’s BIOS Power Management features, the Power Saving option MUST be set to Customize (see Figure 10-1). If the Power Saving setting is not set to Customize, you can perform this operation by pressing the <SPACE> key while the Power Saving option is highlighted.

3.

Press the Down Arrow key < > to highlight the Power Saving feature you wish to set.

4.

Press the <SPACE> key until the desired setting is displayed for the selected option. Continually pressing the <SPACE> key will return you to the start of the available settings for that option. Available options for each feature are listed in the below table. Available Settings OFF 0.125, 0.25, 0.5, 1, 4, 8, and 16 seconds Standby Timeout OFF 8, 16, and 32 seconds (See Note below) 1, 4, 8, and 16 minutes Suspend Timeout OFF 1, 2, 4, 8, 16, 32, and 60 minutes Table 10-1: Available Apex PDT BIOS Power Saving Settings Mode Low Speed Timeout

Note: Units change as individual values are selected.

5.

Once you have set the timeout options to give you the Power Savings desired, press the Right Arrow key < > to go to the BIOS Exit Menu.

6.

To save any changes that you have performed, choose the Save Changes And Exit Option and press the <ENT> key. The following message will appear: Notice Changes have been saved [continue] Pressing the <ENT> key again will return you to the boot sequence.

10-4

COAM30002

Rev. 2.00

8/13/02

Page 149

Apex PDT Technical Reference Manual

10 Power Management

Power Management Interrupts Power Management Interrupt 15h is available for programmers to access the power status of the Apex PDT Battery Pack during usage. The Battery Pack’s charge status is returned as a percentage number (0-100) of the remaining Battery Pack life. Due to the system resources utilized by this interrupt function (see Interrupt Notes), its use should be minimized during normal system operations. Specific interrupt information is shown below for a more detailed description of the interrupt functions.

Service 0Ah – Get Power Status Input:

ah = 53h al = 0Ah bx = 0001h

Returns:

If successful, Carry = 0 bh = AC line status 00h Off-line 01h On-line FFh Unknown All other values reserved bl = Battery status 00h High 01h Low 02h Critical 03h Charging FFh Unknown All other values reserved ch = Battery flag bit 0 = 1 High bit 1 = 1 Low bit 2 = 1 Critical bit 3 = 1 Charging bit 4 = 1 Battery not present bit 7 = 1 No system battery All other bits reserved FFh Unknown cl = Remaining Battery Pack capacity 0 to 100 (percentage of full charge) = FFh (Unknown) si = Number of battery units currently installed (0 or 1) If unsuccessful, Carry = 1 See the following page.

Notes

COAM30002

Rev. 2.00

8/13/02

10-5

Page 150

Apex PDT Technical Reference Manual

10 Power Management

Interrupt 15h - Power Services continued Notes

This function is used to monitor various power status conditions of the Apex PDT including the remaining Battery Pack capacity. This function can take as long as 70 ms to execute; therefore, to avoid undue system burden and delay, do not perform this function more often than necessary. For the Apex III PDT’s Battery Pack's internal Gas Gauge to maintain accuracy, the Battery Pack must be depleted until the system detects a Low Battery status. Application programs that perform preemptive low battery determination based on Battery Pack capacity (cl) will cause the Gas Gauge to become inaccurate. Battery Pack capacity monitoring should be done for information purposes only and not for the purpose of determining a low battery condition. The internal gas gauge is not present in the Apex IV Battery pack. See the Apex PDT Programming Resource section for high level Battery Status function information.

Ways to Conserve Apex PDT Power Because the Apex PDT is a battery-powered device, power management is an important feature. The Apex PDT has built-in power management that is transparent to the application program and to the user; however, for maximum power savings the application program and user can actively participate in the power management by adhering to the following guidelines: q q q q q q

10-6

TURN OFF the scanner aiming beam (bcdriver aimtm=0) if the aiming beam is not required by the application. If the aiming beam is required, use the shortest acceptable duration. SET the scanner beeper duration) as short as acceptable (bcdriver beep=ms,freq). TURN OFF the infrared port (ir off) when not in use. TURN OFF the backlight (<FN>+<L>) when not in use. POWER OFF the unit (<FN>+<Power>) when the unit will not be used for an extended period. ENABLE BIOS Power Management and set the timeouts as short as acceptable.

COAM30002

Rev. 2.00

8/13/02