Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 7

Code Reader 3500 User Manual, pages 51 to 60

Pages 51 to 60 of 64

The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Code CR3500

Page 51

4.3 - Backlight Intensity Settings Scan the following codes to set the intensity of the CR3500’s backlight with High being the brightest and Low being the dimmest: Low

Med - Default

High

4.4 - Backlight Timeout Settings Scan the following codes to set the backlight settings: Backlight Off

3 seconds (Default)

6 seconds

10 seconds

4.5 - Targeting Settings Scan the following codes to turn targeting on/off: On (Default)

Off

4.6 - Reader Power Off Settings Scan the following codes to set the amount of time before a reader powers off: 1 Hour

Save Settings

2 Hours - Default

4 Hours

C004387_07_CR3500_ User_Manual - 45

Page 52

4.7 - Reader ID and Firmware Version To find out the Reader ID and firmware version, open a text editor program (i.e., Notepad, Microsoft Word, etc.) and read the following code: Reader ID and Firmware

You will see a text string indicating your firmware version and CR3500ID number (see below):

Xap/iVVVVWWWWXXXXSSSSSSSSSSPXX-XX+XXX

Xap/i - Code Internal ID (not applicable) VVVV is the application firmware version number WWWW is the bootloader firmware version number XXXX is the radio firmware version number SSSSSSSSSS Reader’s serial number (ten digits) P is “A” if running firmware is the application, “B” if BootLoader XXX-XX+XX - Internal ID (not applicable) Example: Xap/i3000300006040010002363A06D-SD+SQ Note: Code will periodically release new firmware for CR3500 readers. For information on latest firmware versions, call Code at (801) 495-2200. To upgrade firmware, please visit our website at http://www.codecorp.com/codesupport/html and follow instructions provided.

4.8 - Reader Settings Lock To lock or unlock the current settings on your reader please scan the codes below: Reader Settings Locked

Reader Settings Unlocked

NOTE: Prefix and Suffix programming codes, memory transfer and delete commands, “Clear All CodeXML® Rules” and “Suffix -Erase/None”commands are not locked by this feature.

Save Settings

C004387_07_CR3500_User_Manual - 46

Page 53

4.9 - Time Stamp Settings CR3500 has a battery-powered real time clock embedded in the reader. When enabled, the time stamp will be a prefix to the data. Time stamping continues until disabled. The time stamp will be shown in the following format: YYYY-MM-DD HH:MM:SS On

Off (Default)

Note: Turning on the time stamp feature will cause the reader to re-start. Make sure previous settings have been saved prior to scanning the code or you will lose unsaved settings.

4.10 - Lock-out Link Mode This mode can be used to establish a permanent connection between the reader and a CodeXML® modem, Prepare the reader to communicate in ‘RF Comm Mode’ by scanning the QuickConnect code on the paired modem to which you wish to establish a permanent link. Listen for the single beep to verify the connection acknowledgement. Scan the Lockout Link Mode code (see below). Set appropriate timeout settings, if applicable (see Section 1.4.5). To reassign a permanent connection to a different reader, scan the unlock link code. Using the ‘new’ reader’ follow the directions outlined in the previous paragraph. Lockout Link Mode

Save Settings

Unlock Link Mode

C004387_07_CR3500_ User_Manual - 47

Page 54 read from a scan by OCR; it may hold reading errors

Chapter 5 - Advanced Decode Performance

Wi="* Save Settings C004387_07_CR3500_User_Manual - 48 E

M188 _02

Page 55

5.1 - Set Targeting Zone Tolerances The targeting tolerance is the zone around the green LED which is eligible for decoding. The values of each of the following codes are the percent tolerance based on the size of the barcode. As the targeting tolerance becomes smaller the targeting green LED must be more centered in the symbol being read. Conversely, as the targeting tolerance gets larger there is less precision needed with the green LED. If there is more than one decodable code in the field of the, the symbol closest to the targeting green LED will be decoded.

50 Most Accurate

75

100

125

150

200

400

1600 (Default) Least Accurate

Save Settings

C004387_07_CR3500_ User_Manual - 49

Page 56

5.2 - Windowing If only one size of bar code is being scanned in an application, the CR3500 can be optimized to reduce processing time by adjusting the viewing area within the field of view of the image. By reducing the vertical window value of the imager to 200 pixels, 1-D codes are processed more quickly. Because only a horizontal strip of a 1-D code is needed to be decoded, using a narrow strip of the imager is all that is needed. The area above and below the 200 pixels, which is always in the center of the imager, is ignored. This approach reduces the number of pixels that must be processed. Windowing can improve the processing time of 1D and 2D codes. You may negatively impact reader performance if the window size is too small. If it is necessary to have the reader farther away than normal to read the code, the window may be too small. Reading other types of codes, especially large codes, may be difficult while using this setting.

SAMPLE

SAMPLE Medium Code Windowing

Save Settings

SAMPLE

Small Code Windowing

C004387_07_CR3500_User_Manual - 50

Page 57

5.2 - Windowing (Continued) Users may optimize the CR3500 decode zone if their application only requires one bar code format. If the size and density of the bar codes to be scanned are consistent, please select the setting below that best describes your environment. 1-Dimensional Codes ONLY (1024 X 200 pixels)

Caution: It may be more difficult to read other codes while in this setting. You must have the reader farther away than normal. Small 2-Dimensional Codes (480 x 480 pixels)

Medium 2-Dimensional Codes (512 x 512 pixels)

Large 2-Dimensional Codes (640 x 640 pixels)

Reset to Default Setting (1024 X 640 pixels)

5.3 - Mirror Decoding Scan the following codes to enable/disable the mirroring feature: On

Off (Default)

Note: The Mirroring feature allows the CR3500 to read codes as they are seen through a mirror (inversed 180°). If the Mirroring feature is enabled, non-mirrored reading ability will be disabled.

5.4 - Anti-Glare Anti-glare technology improves performance on highly reflective surfaces. The CR3500 will detect when the glare from the illumination LEDs is preventing the reader from being able to decode the bar code. Once glare is detected the reader will attempt to control the illumination LEDs to remove or reduce the glare thereby improving performance. Enable Anti-glare (default)

Save Settings

Disable Anti-glare

C004387_07_CR3500_ User_Manual - 51

Page 58

Chapter 6 - Adding a Prefix or Suffix and Reader Text Commands

Save Settings

C004387_07_CR3500_User_Manual - 52

Page 59

6.1 - Prefix Settings If you scan the following codes, you will lose any unsaved settings. Make sure to save settings on your reader before scanning the prefix codes. If you scan more than one prefix you will receive each scanned prefix in your scanned data; (i.e., if you scan comma prefix twice, you will get two comma prefixes). Scan the following codes to set appropriate prefix: Prefix - Comma

Prefix - Tab (Serial)

Prefix - Space

Prefix - Tab (Keyboard Mode)

Prefix - Erase

Prefix - Carriage Return Line Feed

(Serial)

Note: If you require a special configuration, please contact Code at (801) 495-2200 or email appeng@codecorp.com.

6.2 - Suffix Settings If you scan the following codes, you may lose your current settings. Make sure to save settings on your reader before scanning the Suffix codes. If you scan more than one suffix you will receive each scanned suffix in your scanned data; (i.e., if you scan comma suffix twice, you will get two comma suffixes). Scan the following codes to set appropriate suffix: Suffix - Carriage Return (Serial)

Suffix - Comma

Suffix - Line Feed (Serial)

Suffix - Carriage Return Line Feed (Serial)

Suffix - Space

Suffix - Enter (USB Keyboard)

Suffix - Tab (USB Keyboard)

Suffix - Tab (Serial)

Suffix - Erase

Save Settings

C004387_07_CR3500_ User_Manual - 53

Page 60

6.3 - Erase Prefix and Suffix Settings Scan the following codes to erase all prefix and suffix data. Erase Prefix & Suffix Data

6.4 - Reader Text Commands Enabling Reader Text Commands allows the CR3500 to accept text commands via RS232 or RF communication. Scan the following codes to enable/disable reader text commands: Reader Text Commands On

Reader Text Commands Off - Default

Note: Text commands can only be sent to the reader when it is active. See Reader-Host Interface Document for more information.

Save Settings

C004387_07_CR3500_User_Manual - 54