The text of a manual · part 5 of 7
Code Reader 3500 User Manual, pages 41 to 50
Pages 41 to 50 of 64
The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Code CR3500
Page 41
Chapter 3 - CR3500 Programming: Symbology Settings
Save Settings
C004387_07_CR3500_ User_Manual - 35
Page 42
3.1 - Aztec Symbology Scan the following codes to enable/disable Aztec symbology settings: Aztec On
Aztec Off (Default)
Sample Aztec Code
3.2 - Codabar Symbology Scan the following codes to enable/disable Codabar symbology settings: Codabar On (Default)
Codabar Off
Sample Codabar
3.3 - Codablock F Symbology Scan the following codes to enable/disable Codablock F symbology settings: Codablock F On
Codablock F Off (Default)
Sample Codablock F Code
Note: When Codablock F and Code 128 decoding are enabled, there is some danger of mistakenly decoding a damaged Codablock F symbol as a Code 128 symbol. Therefore, Code 128 decoding should be disabled when Codablock F decoding is enabled.
3.4 - Code 11 Symbology Scan the following codes to enable/disable Code 11 symbology settings: Code 11 On (Default)
Code 11 Off
Code 11 Checksum 2 Digit & Stripped from Result
Code 11 Checksum 1 digit
Code 11 Checksum 1 Digit & Stripped from Result
Code 11 Sample with 1 Checksum Digit
Save Settings
C004387_07_CR3500_User_Manual - 36
Page 43
3.5 - Code 39 Symbology Scan the following codes to enable/disable Code 39 symbology settings: Code 39 On (Default)
Code 39 Off
Enable Checksum
Disable Checksum (Default)
Enable Checksum and Strip From Result
Code 39 Extended Full ASCII On
Code 39 Extended Full ASCII Off (Default)
Code 39 Short Margin On
Code 39 Short Margin Off (Default)
Sample Trioptic Code 39
Code 39 Trioptic On
Code 39 Trioptic Off
Sample Code 39 Code
3.6 - Code 93 Symbology Scan the following codes to enable/disable Code 93 symbology settings: Code 93 On (Default)
Code 93 Off
Sample Code 93 Code
3.7 - Code 128 Symbology Scan the following codes to enable/disable Code 128 symbology settings: Code 128 On (Default)
Code 128 Off
Code 128 Short Margin On
Code 128 Short Margin Off (Default)
Save Settings
Sample Code 128 Code
C004387_07_CR3500_ User_Manual - 37
Page 44
3.8 - Composite Symbologies Scan the following codes to enable/disable Composite symbology settings: Composite On
Composite Off (Default)
3.9 - Data Matrix Symbology Scan the following codes to enable/disable Data Matrix symbology settings: Rectanglular Data Matrix On
Rectangular Data Matrix Off (Default)
Data Matrix Inverse On
Data Matrix Inverse Off (Default)
Enable improved reading capability for hard to decode datamatrix symbols
Disable improved reading capability for hard to decode datamatrix symbols (Default)
Sample Data Matrix Code
Sample Rectangular Data Matrix Code
3.10 - GoCode® Symbology GoCode® is a miniature, two-dimensional (2-D) symbol. Developed to fit within a line of text, GoCode® features a multi-dimensional, adaptable matrix pattern that may be reproduced on virtually any surface. GoCode® is a private symbology and may be utilized by purchasing a runtime license through Code. GoCode® has many significant advantages over all common linear barcodes and 2-D symbols. Please contact Code for more information on the benefits of utilizing a private symbology. Sample GoCode®
Save Settings
C004387_07_CR3500_User_Manual - 38
Page 45
3.11 - Interleaved 2 of 5 Symbology Scan the following codes to enable/disable Interleaved 2 of 5 symbology settings: Int 2 of 5 On (Default)
Int 2 of 5 Off
Int 2 of 5 Two Digits On
Int 2 of 5 Two Digits Off
Int 2 of 5 Four Digits On
Int 2 of 5 Four Digits Off
Sample Int 2 of 5 Code
3.12 - Maxicode Symbology Scan the following codes to enable/disable Maxicode symbology settings: Maxicode On
Maxicode Off (Default)
Sample Maxicode
3.13 - Matrix 2 of 5 Symbology Scan the following codes to enable/disable Matrix 2 of 5 symbology settings: Matrix 2 of 5 On (Default)
Matrix 2 of 5 Off
Matrix 2 of 5 Sample
3.14 - Micro PDF417 Symbology Scan the following codes to enable/disable micro PDF 417 symbology settings: MicroPDF417 On
Save Settings
MicroPDF417 Off (Default)
Sample MicroPDF417
C004387_07_CR3500_ User_Manual - 39
Page 46
3.15 - MSI Plessy Symbology Scan the following codes to enable/disable MSI Plessy symbology settings: MSI Plessy On
MSI Plessy Off (Default)
Sample MSI Plessy
3.16 - NEC 2 of 5 Symbology Scan the following codes to enable/disable NEC 2 of 5 symbology settings: NEC 2 of 5 On (Default)
NEC 2 of 5 Off
3.17 - Optical Character Recognition (OCR) The Code Reader can read Optical Character Recognition (OCR) texts. The following codes can be used to enable/disable this feature. Fonts supported include Passport, ISBN, Price, MICR13, and a user defined template: Disable OCR
(Default)
Enable OCR
Purchase of OCR license required. Note: See Reader Host Interface Document for more details.
3.18 - PDF 417 Symbology Scan the following codes to enable/disable PDF 417 symbology settings: PDF 417 On (Default)
PDF417 Off
Macro PDF 417 Off (Default)
Sample PDF 417 Code
Save Settings
Macro PDF 417 On
C004387_07_CR3500_User_Manual - 40
Page 47
3.19 - Pharmacode For an explanation of Pharmacode settings and all programming codes please refer to Appendix G of the CR3500 User Manual. You may download the Appendix G at: http://www.codecorp.com/manuals.php
3.20 - Postal Symbologies All postal code default settings are OFF. Scan the following codes to enable the appropriate Postal symbology: Note: If you wish to change which Postal code is activated, you MUST first scan the disable all postal codes symbol and then scan your desired symbology. Australian Post On
Japan Post On
KIX
Planet On
Postnet On
Postnet and Planet On
Royal Mail On
Disable All Postal Codes (Default)
Sample Postnet Code
4-State CB On (Intelligent Mail)
3.21 - QR Code Symbology Scan the following codes to enable/disable QR Code symbology settings: QR Code On
QR Code Off (Default)
Enable Checksum
Disable Checksum (Default)
QR Code Inverse On
Both Inverse and Standard On
All QR On (includes Micro QR)
Inverse QR and Micro QR On
Sample QR Code
Sample Micro QR
Save Settings
C004387_07_CR3500_ User_Manual - 41
Page 48
3.22 - GS1 Data Bar (formerly RSS) Symbology Scan the following codes to enable/disable GSS Data Bar (formerly RSS) symbology settings: GS1 Data Bar Limited On
GS1 Data Bar 14 Truncated On
GS1 Data Bar 14 Stacked On
GS1 Data Bar Expanded On
All GS1 Data Bar On
All GS1 Data Bar Off (Default)
Sample RSS Limited Code
Sample RSS 14 Code
Sample RSS 14 Truncated Code
Sample RSS 14 Stacked Code
3.23 - Telepen Symbology Scan the following codes to enable/disable Telepen symbology settings: Telepen On - Default
Telepen Off
Sample Telepen
3.24 - UPC/EAN/JAN Scan the following codes to enable/disable UPC/EAN/JAN symbology settings: UPC On (Default)
UPC Off
UPC Short Margin Enabled
UPC Short Margin Disabled (Default)
UPC-E Expansion On
UPC-E Expansion Off
Sample UPC A Code
Save Settings
C004387_07_CR3500_User_Manual - 42
Page 49
Chapter 4 - Reader Feedback and Special Settings
Save Settings
C004387_07_CR3500_ User_Manual - 43
Page 50
4.1 - Volume and Vibration Settings Scan the following codes to set vibration mode: Vibrate On / Beep On
Vibrate On / Beep Off
Vibrate Off / Beep On (Default)
Scan the following codes to set your reader’s volume: Beep Off
Beep Low
Beep High (Default)
Scan the following codes to set the volume for keypad button press sounds: Off (Default)
Low
Medium
High
4.2 - Code Readability Index The Readability Index provides a measurement of a specific symbol’s ease or difficulty to be decoded by the CR3500. The Readability Index is specific to the CR3500, and should not be confused with a verification quality measurement. The Readability Index is a blend of information obtained from the internal operations of the decoding algorithm pertaining to contrast, symbology construct, error detection, forward error correction (if applicable), and other symbology-specific characteristics. The Readability Index is a score on a scale of 01 (very poor) to 100 (very readable). Due to differences based on motion, skew, reflection, focus, and ambient lighting, the Readability Index on the same symbol may vary somewhat from read to read. However, a poor contrast or damaged symbol will score lower than a high contrast undamaged symbol. The Readability Index can be used as a quick check on the reliability of label generation or marking systems. When used in conjunction with the CR3500 stand (or fixed mount positioning) which fixes the distance from the reader to the symbol, and constant ambient light, the Readability Index provides a symbol quality assurance tool and check point for feedback to an overall label or marking quality control system.
Code Readability Index Rule:
Readability Index Output Enable: Readability Index Output Disable:
Each time a data symbol is read, the index will be output, followed by a comma, (,) followed by the decoded data. The reader will store the rule and reset, but will not output the Readability Index until the Readability Index Output Enable code is read. The Reader will continue to output the Readability Index upon every read until disabled, either by reset or by reading the Readability Index Output Disable code. Save Settings
C004387_07_CR3500_User_Manual - 44