For the Code CR1200

Page 21

4.1 - Operational Modes The CR1200 can operate in either of two modes: • •

Triggered (default mode) Continuous Read

In Triggered mode, the CR1200 reads a code in response to a trigger press. In Continuous Read mode the CR1200 continuously attempts to read a code without operator intervention. Continuous Read mode includes options to specify delays between attempts to read and to limit the duplicate readings of the same code.

4.2.1 - Continuous Read Mode Read the following codes to turn continuous reading on or off: Continous Scan - On

Continous Scan Off (Default)

4.2.1.1 - Read Delays Read the following codes to set delay time between reads: 0 Seconds (Default)

1 Second

3 Seconds

4.2.1.2 - Duplicate Rejection Period The Duplicate Rejection Period defines a time interval. If a read during this interval duplicates the immediately preceding code, the read will be rejected. Read the following codes to set the delay time before the reader accepts a duplicate code: 0 Seconds (Default)

Save Settings

1 Second

3 Seconds

C003525_06_CR1200_User_Manual

16

Page 22 read from a scan by OCR; it may hold reading errors

Chapter 5 - Setting Symbology

Wi="~ Save Settings C003525 06 _CR1200 User Manual 17 &

MI88_02

Page 23

This section describes how to change the symbology settings on the CR1200. Use the codes in this section to specify the set of symbologies that you want the CR1200 to check for during a code read. Careful selection of your symbology set improves CR1200 performance.

5.1 - Aztec Symbology Scan the following codes to enable/disable Aztec symbology settings: Aztec On

Aztec Off (Default)

Sample Aztec Code

5.2 - Codabar Symbology Scan the following codes to enable/disable Codabar symbology settings: Codabar On (Default)

Codabar Off

Sample Codabar

5.3 - Codablock F Symbology Scan the following codes to enable/disable Codablock F symbology settings: Codablock F On

Codablock F Off (Default)

Sample Codablock F Code

Note: When Codablock F and Code 128 decoding are enabled, there is some risk of mistakenly decoding a damaged Codablock F symbol as a Code 128 symbol. Therefore, Code 128 decoding should be disabled when Codablock F decoding is enabled.

Save Settings

C003525_06_CR1200_User_Manual

18

Page 24

5.4 - Code 11 Symbology Scan the following codes to enable/disable Code 11 symbology settings: Code 11 On (Default)

Code 11 Off

Code 11 Checksum 2 Digit & Stripped from Result

Code 11 Checksum 1 Digit & Stripped from Result

Code 11 Checksum 1 digit

Code 11 Sample

5.5 - Code 39 Symbology Scan the following codes to enable/disable Code 39 symbology settings: Code 39 On (Default)

Code 39 Off

Disable Checksum (Default)

Enable Checksum and Strip From Result

Code 39 Extended Full ASCII On

Code 39 Extended Full ASCII Off (Default)

Code 39 Short Margin On (Default)

Code 39 Short Margin Off

Code 39 Trioptic On

Code 39 Trioptic Off

Save Settings

Enable Checksum

Sample Code 39 Code

Sample Trioptic Code 39

C003525_06_CR1200_User_Manual

19

Page 25

5.6 - Code 93 Symbology Scan the following codes to enable/disable Code 93 symbology settings: Code 93 On (Default)

Code 93 Off

Sample Code 93 Code

5.7 - Code 128 Symbology Scan the following codes to enable/disable Code 128 symbology settings: Code 128 On (Default)

Code 128 Off

Code 128 Short Margin On (Default)

Code 128 Short Margin Off

Sample Code 128 Code

Note: When Codablock F and Code 128 decoding are enabled, there is some danger of mistakenly decoding a damaged Codablock F symbol as a Code 128 symbol. Therefore, Code 128 decoding should be disabled when Codablock F decoding is enabled.

5.8 - Composite Symbologies Scan the following codes to enable/disable Composite symbology settings: Composite On

Save Settings

Composite Off (Default)

C003525_06_CR1200_User_Manual

20

Page 26

5.9 - Data Matrix Symbology Scan the following codes to enable/disable Data Matrix symbology settings: Rectanglular Data Matrix On

Rectangular Data Matrix Off (Default)

Data Matrix Inverse On

Data Matrix Inverse Off (Default)

Enable improved reading capability for hard to decode datamatrix symbols.

Disable improved reading capability for hard to decode datamatrix symbols. (Default)

Sample Data Matrix Code

Sample Rectangular Data Matrix Code

5.10 - GoCode Symbology GoCode is a miniature, two-dimensional (2-D) symbol. Developed to fit within a line of text, GoCode features a multi-dimensional, adaptable matrix pattern that may be reproduced on virtually any surface. GoCode is a private symbology and may be utilized by purchasing a runtime license through Code. GoCode has many significant advantages over all common linear barcodes and 2-D symbols. Please contact Code for more information on the benefits of utilizing a private symbology.

Sample GoCode

5.11 - Interleaved 2 of 5 Symbology Scan the following codes to enable/disable Interleaved 2 of 5 symbology settings: Int 2 of 5 On (Default)

Int 2 of 5 Off

Int 2 of 5 Two Digits On

Int 2 of 5 Two Digits Off

Int 2 of 5 Four Digits On

Int 2 of 5 Four Digits Off

Sample Int 2 of 5 Code

Save Settings

C003525_06_CR1200_User_Manual

21

Page 27

5.12 - Maxicode Symbology Scan the following codes to enable/disable Maxicode symbology settings: Maxicode On

Maxicode Off (Default)

Sample Maxicode

5.13 - Matrix 2 of 5 Symbology Scan the following codes to enable/disable Matrix 2 of 5 symbology settings: Matrix 2 of 5 On (Default)

Matrix 2 of 5 Off

Matrix 2 of 5 Sample

5.14 - Micro PDF417 Symbology Scan the following codes to enable/disable micro PDF 417 symbology settings: MicroPDF417 On

MicroPDF417 Off (Default)

Sample MicroPDF417

5.15 - MSI Plessy Symbology Scan the following codes to enable/disable MSI Plessy symbology settings: MSI Plessy On

MSI Plessy Off (Default)

Sample MSI Plessy

5.16 - NEC 2 of 5 Symbology Scan the following codes to enable/disable NEC 2 of 5 symbology settings: NEC 2 of 5 On

Save Settings

NEC 2 of 5 Off (Default)

C003525_06_CR1200_User_Manual

22

Page 28

5.17 - Optical Character Recognition (OCR) The Code Reader can read Optical Character Recognition (OCR) texts. The following codes can be used to enable/ disable this feature. Fonts supported include Passport, ISBN, Price, MICR13, and a user defined template:

Disable OCR (Default)

Enable OCR Purchase of OCR license required.

5.18 - PDF 417 Symbology Scan the following codes to enable/disable PDF 417 symbology settings: PDF 417 On (Default)

PDF417 Off

Macro PDF 417 Off (Default)

Sample PDF 417 Code

Macro PDF 417 On

5.19 - Pharmacode For an explanation of Pharmacode settings and all programming codes please refer to Appendix G of the CR1200 User Manual. You may download Appendix G at: http://www.codecorp.com/manuals.php

5.20 - Postal Symbologies All postal code default settings are OFF. Scan the following codes to enable the appropriate Postal symbology: Australian Post On

Japan Post On

KIX On

Postnet On

Postnet and Planet On

Royal Mail On

Disable All Postal Codes (Default)

Sample Postnet Code

4-State CB On (Intelligent Mail)

Save Settings

Planet On

C003525_06_CR1200_User_Manual

23

Page 29

5.21 - QR Code Symbology Scan the following codes to enable/disable QR Code symbology settings: QR Code On

QR Code Off (Default)

Enable Checksum

Disable Checksum (Default)

QR Code Inverse On

Both Inverse and Standard On

All QR On (includes Micro QR)

Inverse QR and Micro QR On Sample QR Code

Sample Micro QR

5.22 - GS1 data bar (formerly RSS) Symbology Scan the following codes to enable/disable GS1 data bar (formerly RSS) symbology settings: GS1 data bar Limited On Truncated On

GS1 data bar 14 Stacked On

GS1 data bar Expanded On (Default) All GS1 data bar On

All GS1 data bar Off

Sample GS1 data bar Limited Code

Sample GS1 data bar 14 Code

Sample GS1 data bar 14 Truncated Code

Sample GS1 data bar 14 Stacked Code

Save Settings

C003525_06_CR1200_User_Manual

24

Page 30

5.23 - Telepen Symbology Scan the following codes to enable/disable Telepen symbology settings: Telepen On - Default

Telepen Off

Sample Telepen

5.24 - UPC/EAN/JAN Scan the following codes to enable/disable UPC/EAN/JAN symbology settings: UPC On (Default)

UPC Off

UPC Short Margin Enabled (Default)

UPC Short Margin Disabled

UPC Extension On

UPC Extension Off

Sample UPC A Code

Save Settings

C003525_06_CR1200_User_Manual

25