Page 11
2.2.1.2 - Addional USB Communication Settings USB Keyboard Mode - Data is sent from the Reader and interpreted by the host just as if a USB keyboard was being used to enter data. USB Downloader - This mode is used when downloading firmware. USB Native Two Way Mode - This mode is utilized when there is a need for error-corrected communication between the CR1200 and an application through the USB port. USB Virtual COM 1 Way Mode - This mode allows a USB-cabled CR1200 to function as a virtual COM port. To use the CR1200 in this mode, download the driver at www.codecorp.com/downloads.php. USB HID POS (Terminal ID 131) - This mode allows a USB-cabled CR1200 to communicate as a USB HID POS (Terminal ID 131) device. Scan the following codes to set the appropriate USB communication setting: USB Keyboard
USB Downloader
USB Native Two Way Mode
USB Virtual COM 1 Way Mode
USB HID POS (Terminal ID 131)
2.2.1.3 - Keyboard Support Scan the following codes to set appropriate keyboard mapping: US English (Default) No Leading 0 for non-printable characters
French
German
Custom Keyboard Requests map to be installed
Save Settings
US English - Leading 0 for non-printable characters
Japanese
Alternative OS (Windows CE/MAC/Unix/Linux) Enable
US English - ctrl + char for non-printable characters
Universal Keyboard
Alternative OS Disable
C003525_06_CR1200_User_Manual
6
Page 12
2.2.2 - PS/2 Cable Installation Guide CR1200 must have a serial number greater than 10050561 and a firmware version greater than 4126 to use a PS/2 cable. 1. Power off the computer. If you disconnect the computer’s keyboard while it is powered on, your computer will lock up. 2. Attach the the PS/2 cable to the CR1200. 3. If you have a cabled keyboard, detach the keyboard cable from the computer and connect that same connector to the female connection on the CR1200 PS/2 cable (Figure 1.17). 4. Now connect the male CR1200 PS/2 connector into the keyboard port on the computer (Figure 1.18). 5. Power on the computer. The CR1200 is powered by the PS/2 port and does not require a power supply.
Figure 1.17
PS/2 Factory Reset
Figure 1.18
Save Settings Code does not guarantee compatibility with all models of computers.
Save Settings
C003525_06_CR1200_User_Manual
7
Page 13
2.2.3 - RS-232 (Serial) Cable Installation Guide 1. Attach the RS-232 (Serial) cable to the CR1200. 2. Connect the RS-232 (Serial) cable to a serial port on the computer (Figure 1.19). There is no need to power off the computer. 3. The RS-232 (Serial) interface has an optional 5V/1.5A power supply (Figure 1.20). If you have a power supply, plug the power supply adapter into the RS-232 (Serial) cable and then plug the power adapter into a wall socket (Figure 1.21).
Figure 1.19
Figure 1.20
Figure 1.21
4. Once properly connected, the CR1200 will power on and beep. 5. For RS-232 (Serial) mode scan M418_02 (below). If the power supply is not connected scan M074_02 (below). 6. Scan the Save Settings Code (M188_02). RS-232 (Serial)
RS-232 (Serial) Mode
Factory Reset
No Power Supply
Save Settings
RS-232 Factory Default Settings Mode: RS-232 One Way Mode Baud Rate: 57600 Stop Bits: 2 Data Bits: 8 Parity: None
Warning: Code Corporation approved power adapter must be used. Reader failure due to use of incorrect power adapter will void warranties.
Save Settings
C003525_06_CR1200_User_Manual
8
Page 14
2.2.3.1 - Additional RS-232 (Serial) Communication Data Bit Settings Scan the following codes to set the appropriate data bit: 7 Data Bits
8 Data Bits (Default)
2.2.3.2 - Additional RS-232 (Serial) Communication Baud Rate Settings Scan the following codes to set the appropriate baud rate: 1200
2400
4800
9600
19200
38400
57600 (Default)
115200
2.2.3.3 - Additional RS-232 (Serial) Communication Parity Settings Scan the following codes to set parity: Even
Odd
None (Default)
2.3.1 - Cabled Reader - Time Out Settings Scan one of the codes below to set the amount of time a cabled CR1200 will be enumerated before entering sleep mode. Note: These settings will only work in versions 2098 and above. Cabled Reader Time Out: 2 hours
Save Settings
Cabled Reader Time Out: Never (Default)
C003525_06_CR1200_User_Manual
9
Page 15
Chapter 3 - Optimization and Trigger Programming
Wi Save Settings C003525_06_CR1200_User_Manual 10 r MI188_02
Page 16
3.1 - Specifying Feedback The CR1200 features one LED on the top of the unit. The LED gives visual feedback based on the operation of the CR1200 (see Table 3.1). The LED may display Red, Amber, or Green. Configurable sound and vibration features provide audible and tactile feedback.
Figure 3.1
Condition
Sound/Vibration
LED Sequence: Amber Green Amber
Successful Power Up
1 Beep/Vibration
Successful connection with the host via USB cable
1 Beep/Vibration
None
Sucessful decode and data transfer to the host
1 Beep/Vibration
Flash Green
Configuration Code suffessfully decoded and processed
2 Beeps/Vibrations separated by a slight pause
Flash Green
Table 3.1 LED Feedback Conditions Read the following codes to set the beep and vibration modes: Vibration On / Beep On (Default)
Save Settings
Vibrate On / Beep Off
Vibrate Off / Beep On
C003525_06_CR1200_User_Manual
11
Page 17
3.2 - Targeting The CR1200 targeting implementation projects two LED-generated images to aid you in properly positioning and focusing the reading operation. Figure 3.2 graphically displays the field of view of the CR1200 reader and shows the areas of that field of view where various codes can be read. Targeting the code becomes more important as the size of the code decreases and the density increases. The optimal distance to read a code is 3.8” (9.7 centimeters). The LED targeting guides projected by the CR1200 help to detect this optimal reading distance.
Figure 3.2
Save Settings
C003525_06_CR1200_User_Manual
12
Page 18
The CR1210 targeting implementation projects two LED-generated images to aid you in properly positioning and focusing the reading operation. Figure 3.3 graphically displays the field of view of the CR1210 reader and shows the areas of that field of view where various codes can be read. Targeting the code becomes more important as the size of the code decreases and the density increases. The optimal distance to read a code is 2.3.” (5.8 centimeters). The LED targeting guides projected by the CR1210 help to detect this optimal reading distance.
Figure 3.3
Save Settings
C003525_06_CR1200_User_Manual
13
Page 19
3.2 - Targeting As shown in Figure 3.4, the red targeting LED identifies the center of the reading operation and aids in centering a code in the reader’s field of view. The green LED provides focusing assistance to aid in positioning the CR1200 at the optimum distance for a read. Center the CR1200’s red LED display on the code and then move the unit closer to or farther away from the bar code until the green LED image merges with the red LED image. Correct positioning of the CR1200 is essential to reduce reading time. For optimal reading conditions, the red and green LED images must converge at the center of the code.
Too far from code
Too close to code
Optimal distance from code is 3.8” (9.7 cm) for the CR1200. Optimal from code is 2.3” (5.8 cm) for the CR 1210.
Figure 3.4 Read the appropriate code below to turn the targeting features on/off for Red and Green LEDs: Red Targeting LED On
Red Targeting LED Off
Green Targeting LED On
Green Targeting LED Off
3.3 - Reading Techniques The CR1200 uses digital imaging technology to take a picture of a symbol. Once an image is captured, the CR1200 uses advanced decoding algorithms to extract data from the captured image. To read a symbol with the CR1200: 1. 2. 3.
Target the CR1200 on the center of the code. (See section 3.2). Hold the CR1200 still. Do not swipe or move the reader. Press the trigger until the CR1200 beeps and vibrates, indicating the code has been successfully read.
Save Settings
C003525_06_CR1200_User_Manual
14
Page 20
Chapter 4 - Optimization and Trigger Programming
Wi="~ Save Settings C003525 06 _CR1200 User Manual 15 &
MI88_02