The text of a manual · part 1 of 2
Code Reader 1000 User Manual, pages 1 to 7
Pages 1 to 7 of 13
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Code CR1000
Page 1
User Manual
Code Reader™ 1000 Manual Version 05 Release Date: July 2013 C005905_05_CR1000_User_Manual C005905_05_CR1000_UserManual
Page 2
Statement of Agency Compliance The Code Reader™ 1000 (CR1000) has been tested for compliance with FCC regulations and was found to be compliant with all applicable FCC Rules and Regulations. IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The Code Reader 1000 has been tested for compliance to CE standards and guidelines and was found to conform to applicable CE standards, specifically the EMC requirements EN 55024, ESD EN 61000-4-2, Radiated RF Immunity EN 61000-4-3, ENV 50204, EFT EN 61000-4-4, Conducted RF Immunity EN 61000-4-6, EN 55022, Class B Radiated Emissions, and Class B Conducted Emissions. Code voids product warranty if the hard case has been opened or tampered with in any way. In addition, a CB Test Certificate has been issued by the National Certification Board (NCB) indicating CR1000 meets all safety and quality standards in accordance to IEC 60950-1:2001, First Edition.
C005905_05_CR1000_User_Manual
Page 3
Code Reader™ 1000 User Manual Copyright © 2013 Code Corporation. All Rights Reserved. The software described in this manual may only be used in accordance with the terms of its license agreement. No part of this publication may be reproduced in any form or by any means without written permission from Code Corporation. This includes electronic or mechanical means such as photocopying or recording in information storage and retrieval systems. NO WARRANTY. This technical documentation is provided AS-IS. Further, the documentation does not represent a commitment on the part of Code Corporation. Code Corporation does not warrant that it is accurate, complete or error free. Any use of the technical documentation is at the risk of the user. Code Corporation reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Code Corporation to determine whether any such changes have been made. Code Corporation shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. Code Corporation does not assume any product liability arising out of or in connection with the application or use of any product or application described herein. NO LICENSE. No license is granted, either by implication, estoppel, or otherwise under any intellectual property rights of Code Corporation. Any use of hardware, software and/or technology of Code Corporation is governed by its own agreement. The following are trademarks or registered trademarks of Code Corporation: CodeXML®, Maker, QuickMaker, CodeXML® Maker, CodeXML® Maker Pro, CodeXML® Router, CodeXML® Client SDK, CodeXML® Filter, HyperPage, CodeTrack, GoCard, GoWeb, ShortCode, GoCode®, Code Router, QuickConnect Codes, Rule Runner®, Cortex®, CortexRM, CortexMobile, Code, Code Reader, CortexAG, CortexStudio, CortexTools, Affinity®, and CortexDecoder. All other product names mentioned in this manual may be trademarks of their respective companies and are hereby acknowledged. The software and/or products of Code Corporation include inventions that are patented or that are the subject of patents pending. U.S. Patents: 6997387, 6957769, 7428981, 6619547, 6736320, 7392933, 7014113, 7240831, 7353999, 7519239, 7204417, 6942152, 7070091, 7097099, 7621453, 8001550, 8011584 The Code Reader software uses the Mozilla SpiderMonkey JavaScript engine, which is distributed under the terms of the Mozilla Public License Version 1.1. The Code Reader software is based in part on the work of the Independent JPEG Group. Code Corporation, 14870 South Pony Express Road, Suite 200, Bluffdale, UT 84065 www.codecorp.com
C005905_05_CR1000_User_Manual
Page 4
Table of Contents 1.0 - Unpacking............................................................................................................................................................... 1 2.0 - Attaching/Detaching a Cable. .................................................................................................................................. 1 3.0 - Powering the Reader On/Off. .................................................................................................................................. 1 4.0 - Using a CR1000 Out of a Stand. ............................................................................................................................... 2 5.0 - Using a CR1000 in a Stand. ...................................................................................................................................... 2 6.0 - Reading Range......................................................................................................................................................... 3 7.0 - Reader Feedback..................................................................................................................................................... 3 8.0 - Symbologies Defaulted On. ..................................................................................................................................... 4 9.0 - Symbologies Defaulted Off. ..................................................................................................................................... 4 10.0 - Locating the Hardware Revision Number............................................................................................................... 4 11.0 - Reader ID & Firmware Version............................................................................................................................... 5 12.0 - Hole Mounting Pattern.......................................................................................................................................... 6 13.0 - CR1000 Overall Dimensions................................................................................................................................... 6 14.0 - USB Cable Example with Pinouts. .......................................................................................................................... 7 15.0 - RS232 Cable Example with Pinouts........................................................................................................................ 7 16.0 - Reader Pinouts...................................................................................................................................................... 8 17.0 - Maintenance......................................................................................................................................................... 8 18.0 - Warranty............................................................................................................................................................... 9
C005905_05_CR1000_User_Manual
Page 5
1.0 - Unpacking Remove the CR1000 from its packing and inspect it for damage. If the reader was damaged during shipping, please call Code at (801) 495-2200. Depending on the kit ordered, a USB or RS232 Affinity® cable has been included with your reader.
USB Affinity® Cable
RS232 Affinity® Cable w/ Power Supply
2.0 - Attaching and Detaching a Cable To attach a cable, plug the RJ-50 end of the Affinity® cable into bottom of the reader (Figure 1). Firmly push the connector into the reader, until a snap can be heard to indicate the cable is properly attached. To detach a cable, press a paper clip into the hole on the back of the CR1000 (Figure 2), and gently pull the cable from the reader.
Figure 1
Figure 2
3.0 - Attaching Cable and Powering On/Off the Reader For USB Cable: plug the USB end of the Affinity® cable into a USB port on the host device. After several seconds, the reader will beep twice, the LED will turn off and the CR1000 is ready for use. For RS232 Cable: plug the power supply into the AC outlet, plug the power supply cord into the barrel jack of the cable, and connect the RS232 connector to the appropriate serial port on the host device. After several seconds, the reader will beep twice, the LED will turn off and the CR1000 is ready for use.
C005905_05_CR1000_User_Manual
1
Page 6
4.0 - Using a CR1000 Out of a Universal Stand Press and hold the button on the top of the CR1000, the two blue bars emitting from the reader are used for targeting. Center the blue bars in the middle of a bar code. The optimal reading distance from reader to bar code is approximately 4.0” (10 cm). Once the reader is at the optimal distance, the reader will read the bar code. The CR1000 will beep and flash a green LED to indicate a ‘good read’ has occurred. To modify any default settings, download the CR1000 Configuration Guide at www.codecorp.com/files.php and scan the appropriate code.
5.0 - Using a CR1000 in a Universal Stand Revision 3 Hardware of the CR1000 has a stand detection feature. By default, when the CR1000 is placed in the stand, the reader will enter into motion detection mode. When in this mode, simply place a bar code in the scan field to activate the reader. The CR1000 will beep and flash a green LED to indicate a ‘good read’ has occurred. When the CR1000 is removed from the stand, the reader switches to manual mode and the button must be pressed to read a bar code (refer to Section 4.0). Revisions 1 and 2 Hardware of the CR1000 do not have a stand detection feature to enable motion detection reading when the CR1000 is in a stand. To configure these hardware revisions for motion detection scanning, please refer to the CR1000 Configuration Guide, located at www.codecorp.com/files.php and scan the appropriate code.
See Section 10.0 to learn how to determine your CR1000 hardware revision number.
C005905_05_CR1000_User_Manual
2
Page 7
6.0 - Reading Ranges CR1000 Performance Test Code
Min Inches (mm)
Max Inches (mm)
3 mil Code 39
3.1” (80 mm)
4.0” (102 mm)
7.5 mil Code 39
1.3” (33 mm)
7.2” (182 mm)
10.5 mil GS1 DataBar
0.8” (20 mm)
8.7” (220 mm)
13 mil UPC
1.1”(28 mm)
11.0” (280 mm)
4.2 mil Data Matrix
1.9” (48 mm)
4.3” (110 mm)
5 mil Data Matrix
1.7” (43 mm)
4.5” (115 mm)
6.3 mil Data Matrix
1.3” (33 mm)
5.9” (150 mm)
10 mil Data Matrix
0.8” (20 mm)
7.1” (180 mm)
20.8 mil Data Matrix
1.1” (28 mm)
13.5” (343 mm)
Note: working ranges are a combination of both the wide and high density fields. All samples were high quality codes and were read along a physical center line at a 10° angle. Default AGC settings were used. Accuracy= +/- 10%.
7.0 - Reader Feedback Scenario
Top LED Light
Sound
CR1000 Successfully Powers Up
Green LED Flashes
1 Beep
CR1000 Successfully Enumerates with Host (via cable)
Once Enumerated, the Green LED turns Off
1 Beep
Attempting to Decode
Green LED Light is Off
None
Successful Decode and Data Transfer via Cable
Green LED Flashes
1 Beep
Configuration Code Successfully Decoded and Processed
Green LED Flashes
2 Beep
Configuration Code successfully decoded but wasn’t successfully processed
Green LED Flashes
4 Beeps
C005905_05_CR1000_User_Manual
3