Page 31

Deployment Example Basic Guidelines Process

Determining How Many Access Points are Needed In this section you define the coverage area for each floor in the building and divide it into rectangles and calculate how many access points are needed by dividing the area of each rectangle by the Z factor squared. The example shown below is for a typical office building with a desired average user throughput of 5 Mbps. Figure 5

Determining the Number of access points

150 ft. APs (Area 1) = (150/77) x (150/77) = 4 APs APs (Area 2) = (450/77) x (150/77) = 12 APs 150 ft.

Total = 16 APs

(Area 2)

450 ft.

150 ft.

135686

(Area 1)

Optional Minimal Site Survey If the building type estimate needs to be verified, a quick minimal site survey can be done to verify the signal strength of the access point for the coverage radius. For example, for a typical office building with a desired average user performance of 12 Mbps a signal strength of -75 dBm or better is needed and the site survey will be used to verify that the -75 dBm coverage radius of a Cisco 1000 Series lightweight access point is 50 feet. Review the “Optional Minimal Site Survey” section of this document for how to perform a site survey using a Cisco 1000 Series lightweight access point.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

13

Page 32

Deployment Optional Minimal Site Survey

Placing Access Points The final step is to determine the installation location of the access point. First, using the radius or Z factor found in Step A, distribute the circles or squares evenly across the rectangles found in Step B. Note that the large “X” in the middle of each coverage area indicates the approximate location of the Cisco 1000 series lightweight access points. Also notice that the Z factor between the centers of each Cisco 1000 series lightweight access point location is the same as the Cisco 1000 series lightweight access point squares when the squares are directly adjacent to each other, as shown in this figure. Figure 6

Access Points Location

Optional Minimal Site Survey If the “Building Type” or RF characteristics assumptions are in doubt, complete this step to verify those assumptions. The minimal site survey consists of the following: •

Collecting Tools and Materials

•

Selecting Cisco 1000 Series Lightweight Access Point Locations

•

Preparing Optional Cisco 1000 Series Lightweight Access Point Tripod Test Assemblies

•

Positioning a Cisco 1000 Series Lightweight Access Point at Each Planned Location

•

Verifying RF Coverage Using the Site Survey Tool

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

14

78-17279-01

Page 33

Deployment Optional Minimal Site Survey

Collecting Tools and Materials Before you start a site survey, you must collect some items: •

Maps or building plans of the areas to be covered, with a feet or meters scale included.

•

Duct Tape and Cable Ties.

•

T-10 Security Torx screwdriver.

•

A PC with a crossover CAT-5 or higher Ethernet cable capable of establishing a telnet session with each Cisco 1000 series lightweight access point.

•

A Site Survey Tool, consisting of a computer equipped with 802.11a and 802.11b/g transceivers and the signal strength monitoring and recording software.

•

Between one and five Cisco 1000 series lightweight access points with power supplies: – Cisco 1000 series lightweight access points. – Available Power Sources: – * Recommended factory-orderable 110 VAC-to-48 VDC power supplies. – * Optional Ethernet Power Injectors: Single RJ-45, 300 mA 48 VDC output, (MILAN Model

MIL-L1611, or equivalent). Refer to “Preparing Optional Cisco 1000 Series Lightweight Access Point Tripod Test Assemblies” for more information. – Recommended temporary stands, such as photographer’s telescoping lighting stands, that can be raised to ceiling height. Refer to “Preparing Optional Cisco 1000 Series Lightweight Access Point Tripod Test Assemblies” for more information. – Optionally, you can temporarily position the Cisco 1000 series lightweight access points at or near ceiling height using ladders and/or tall bookcases, but they do not offer the portability of the Cisco 1000 series lightweight access point tripod test assemblies.

Selecting Cisco 1000 Series Lightweight Access Point Locations Using the Cisco Radio density estimate from “Determining Deployment Requirements” and the guidelines for placing Cisco 1000 series lightweight access points described in “Cisco 1000 Series Lightweight Access Point Placement Guidelines,” determine the location for three to five Cisco 1000 series lightweight access points in a typical test coverage area.

Preparing Optional Cisco 1000 Series Lightweight Access Point Tripod Test Assemblies You do not need to use the optional Cisco 1000 series lightweight access point tripod test assemblies described in this section--you can tape or cable tie the Cisco 1000 series lightweight access points to the ceiling, or place them on tall cabinets or ladders. However, if you must move them from their original positions, having them mounted on the tripod test assembly stands makes it easier to relocate them.

Caution

You only need AC extension cords if you have enough 110 VAC electrical outlets within easy reach of all potential Cisco 1000 series lightweight access point mounting locations. If you do use AC power cords, make sure you use duct tape to avoid creating trip hazards with the extension cords.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

15

Page 34

Deployment Optional Minimal Site Survey

Contact Cisco WLAN Solution for the Cisco 1000 series lightweight access point mounting brackets and recommended telescoping stand screws.

•

Use duct tape and/or cable ties to assemble the telescoping stands, Cisco 1000 series lightweight access points, CAT-5 Ethernet cables, Ethernet power injectors, power inverter, external power supply, battery packs, and/or extension cords as shown in the following figure.

Make sure you support the CAT-5 and power cables to remove harmful stress on the Cisco 1000 series lightweight access point connectors. Figure 7

Cisco 1000 Series Lightweight Access Point Tripod Test Assemblies

AP

AP

CAT5 cable

Power converter cable

110-220 VAC extension cord

Power injector

External power converter

110-220 VAC extension cord

A. Power injector/AC power •

B. Power converter/AC power

135689

Note

•

Continue with “Positioning a Cisco 1000 Series Lightweight Access Point at Each Planned Location.”

Positioning a Cisco 1000 Series Lightweight Access Point at Each Planned Location This section assumes that you have determined the Cisco 1000 series lightweight access point locations as described in “Cisco 1000 Series Lightweight Access Point Placement.” Refer to “Preparing Optional Cisco 1000 Series Lightweight Access Point Tripod Test Assemblies” for instructions on how to power the Cisco 1000 series lightweight access points at each planned location.

Caution

If you are using AC extension cords, make sure you use duct tape to avoid creating trip hazards. •

Using the floor plans and/or maps from “Cisco 1000 Series Lightweight Access Point Placement Guidelines,” place the Cisco 1000 series lightweight access point assemblies at or near the indicated locations.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

16

78-17279-01

Page 35

Deployment Cisco 1000 Series Lightweight Access Point Placement Guidelines

•

If any power is being applied to the Cisco 1000 series lightweight access point, remove the power now.

Verifying RF Coverage Using the Site Survey Tool •

Follow the manufacturer’s instructions supplied with the Site Survey Tool to collect signal strength information from the coverage area being tested.

•

If necessary, reposition the Cisco 1000 series lightweight access point(s) in the coverage area and repeat the previous steps until you have verified coverage, and then continue.

Cisco 1000 Series Lightweight Access Point Placement Guidelines This step describes where and how Cisco 1000 series lightweight access points should be placed. You must know certain information to select Cisco 1000 series lightweight access point locations: •

Collecting Maps or Building Floor Plans

•

Noting Deployment Constraints

•

Access Point Placement Guidelines

•

Cisco 1000 Series Lightweight Access Point Placement

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

17

Page 36

Deployment Cisco 1000 Series Lightweight Access Point Placement Guidelines

Collecting Maps or Building Floor Plans Collect maps or building plans of the areas to be covered, with a feet or meters scale included. Figure 8

Typical Floor Plan -- Open Auditorium with Cubicles

Noting Deployment Constraints If the Cisco 1000 series lightweight access points are to use existing wiring, note these locations on the map. If there are locations where Cisco 1000 series lightweight access points cannot be placed, note these locations on the map.

Access Point Placement Guidelines •

Position the Cisco 1000 series lightweight access points above obstructions.

•

Position the Cisco 1000 series lightweight access points vertically near the ceiling in the center of each coverage area, if possible.

•

Position Cisco 1000 series lightweight access points in locations where users are expected to be. For example, large rooms are typically a better location for Cisco 1000 series lightweight access points than a hallway.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

18

78-17279-01

Page 37

Deployment Cisco 1000 Series Lightweight Access Point Placement Guidelines

Cisco 1000 Series Lightweight Access Point Placement •

Place Cisco 1000 series lightweight access points on the floor plan using the “Noting Deployment Constraints” and “Access Point Placement Guidelines” sections such that coverage circles are touching or slightly overlapping as illustrated in the following example.

Example •

The open auditorium (a Warehouse/Manufacturing Building Type) shown in the “Collecting Maps or Building Floor Plans” section is approximately 20,000 square feet.

•

As described in the “Voice over IP Requirements” section, a typical SpectraLink NetLink Telephone requires approximately 6 Mbps 802.11b throughput, resulting in a minimum A = 5,000 square foot coverage area per Cisco 1000 series lightweight access point for an open area.

•

Dividing 20,000 square feet by A = 5,000 square feet per Cisco 1000 series lightweight access point results in at least four Cisco 1000 series lightweight access points required for the auditorium.

•

According to the guidelines in “Determining Deployment Requirements,” an A = 5,000 square foot coverage area results in an R = 50-foot coverage circle radius, or Z = 71-foot coverage square.

•

On your floor plan map, arrange four 50-foot radius coverage circles so they overlap, as shown in the following figure.

Note

The Cisco 1000 series lightweight access point coverage areas should overlap approximately 10% to 15% to minimize the number of coverage holes.

Note

The large “X” in the middle of each circular Cisco 1000 series lightweight access point coverage area--those are the indicated locations of the associated Cisco 1000 series lightweight access points.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

19

Page 38

Deployment Cisco 1000 Series Lightweight Access Point Placement Guidelines

Figure 9

802.11a Cisco 1000 Series Lightweight Access Point Coverage Areas Arranged on Typical Warehouse Floor Plan

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

20

78-17279-01

Page 39

Deployment Cisco 1000 Series Lightweight Access Point Placement Guidelines

•

See the following figure for a description of what to do if there are any large metal obstructions where you plan to install Cisco 1000 series lightweight access points.

Figure 10

What to do about Metal RF Barriers in a Planned Cisco 1000 Series Lightweight Access Point Location

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

21

Page 40

Deployment Where to Go from Here

•

When you are installing Cisco 1000 series lightweight access points using the “RF Prediction with Optional Site Survey” or “Basic Guidelines with Optional Site Survey” method: – Complete “Optional Minimal Site Survey” for the optional minimal site survey, or – Use the Quick Start Guide: Cisco Aironet 1000 Series Lightweight Access Points with Internal

Antennas or Quick Start Guide: Cisco Aironet 1000 Series Lightweight Access Points with External Antennas to install the Cisco 1000 series lightweight access points without a minimal site survey.

Where to Go from Here You have successfully planned and tested the Cisco 1000 series lightweight access point RF coverage in your target area, and have determined where the Cisco 1000 series lightweight access points are to be located. Continue with Quick Start Guide: Cisco Aironet 1000 Series Lightweight Access Points with Internal Antennas or Quick Start Guide: Cisco Aironet 1000 Series Lightweight Access Points with External Antennas for final installation instructions.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

22

78-17279-01