Page 21

Deployment Determining Deployment Requirements

Protocol Requirements One of the critical decisions in deploying a wireless LAN is deciding which protocols and bands it will support. The following table shows the options and the advantages/disadvantages of each. Table 1

Protocol Requirements

Protocol/Band

Advantage

Disadvantage

802.11a/b/g

Highest capacity option (three 802.11b/g channels and thirteen 802.11a channels)

Small increase in the Cisco 1000 Series IEEE 802.11a/b/g lightweight access point cost

Highest performance option (54 Mbps for both 802.11g and 802.11a) Rogue access point detection for both 2.4 GHz 802.11b/g and 5.0 GHz 802.11a bands 802.11 b/g only

Supports legacy clients Lowest cost Cisco 1000 Series IEEE 802.11a/b/g lightweight access point

802.11g performance is limited in the presence of 802.11b users Limited capacity Does not support 802.11a clients

802.11a only

High performance

Does not support 802.11b/g clients

High Capacity

Coverage Area Requirements Customers typically want seamless full RF coverage or partial RF coverage in conference rooms, lunch rooms, etc. Coverage holes are areas where clients cannot receive a signal from the wireless network. When deploying wireless networks, there is a trade-off between the cost of the initial network deployment and the percentage of coverage hole areas. A reasonable coverage hole criterion for launch is between 2 and 10 percent. This means that between two and ten test locations out of 100 random test locations may receive marginal service. After launch, the Cisco WLAN Solution Radio Resource Management (RRM) will identify these coverage areas and report them to the IT manager, allowing the IT manager to fill holes based on user demand.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

3

Page 22

Deployment Determining Deployment Requirements

Building Type Identifying the building type and its RF characteristics is critical in determining how many Cisco Radios will be needed. The following table shows three basic building types that are common in the enterprise market. If the building does not fall into one of these categories then some amount of professional service may be needed. Table 2

Building Type

Building Type

Description

Typical Office Space

This is the most common enterprise building. This type of building consists of large open cubicle areas with walled offices and conference rooms.

Drywall Office Space

This type of building consists of mostly offices with dry wall characteristics.

Brick/Concrete Walled Office Space

This type of building consists of concrete or brick walls for both exterior and for interior office space. Old buildings found on college campuses are good examples of this type of building.

Other

There are some buildings such as sports arenas and stock exchanges that do not fit into one of the typical categories. These buildings typically require some special consideration or professional service.

Building Homogeneity If the building does not have similar RF characteristics throughout the coverage area, the coverage area needs to be divided into areas with similar characteristics and the design process repeated for each area.

Average Client Throughput The desired average user throughput is 1 Mbps to 18 Mbps. Average client throughput is related to 802.11 protocol and signal strength, and thus Cisco 1000 series lightweight access point density. In terms of protocol, 802.11b can support an average user throughput of up to 6 Mbps and 802.11a and 802.11g can support a typical average user throughput of up to 20 Mbps with reasonable Cisco 1000 series lightweight access point densities. Generally, the stronger the signal, the higher the client throughput. However, as shown in the figure below, there is a point above which a stronger signal does not increase client throughput. For 802.11b networks, this point is typically -75 dBm, above which average client throughput is 5 to 6.5 Mbps regardless of increase in signal strength. For 802.11a networks, this point is typically between -50 dBm and -60 dBm, above which average client throughput is 24 to 30 Mbps regardless of increase in signal strength. Note that for 802.11a, the range over which the average client throughput improves is between -80 dBm and -50 dBm.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

4

78-17279-01

Page 23

Deployment Determining Deployment Requirements

Figure 1

Average Client Throughput versus Signal Strength

The following figures show the relationship between average client performance and Cisco 1000 series lightweight access point density for 802.11a and 802.11b clients. The typical Cisco 1000 series lightweight access point density for most enterprise buildings deployed for full coverage is between 2500 and 7000 square feet per Cisco 1000 series lightweight access point. Figure 2

Average 802.11a Client Throughput versus Cisco 1000 Series Lightweight Access Point Density for Typical Office Spaces

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

5

Page 24

Deployment Determining Deployment Requirements

Figure 3

Average 802.11b Client Throughput versus Cisco 1000 Series Lightweight Access Point Density for Typical Office Spaces

The following table provides a summary of Cisco Radio coverage as a function of building type and average user performance requirements: Table 3

Coverage Area

Area = Z2 (square ft.)

R (ft.)

Z (ft.)

2500

35

50

3000

39

55

3500

42

59

4000

45

63

4500

47

67

5000

50

71

5500

52

72

Z 6000

55

57

6500

57

81

7000

59

84

7500

61

87

8000

63

89

Coverage Area

135685

R

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

6

78-17279-01

Page 25

Deployment Determining Deployment Requirements

Figure 4

Average Client Throughput versus Signal Strength

Table 4

Building Type and Average User Throughput

Average User Throughput Building Type

Measurement (See Note 1)

1 Mbps

5 Mbps

12 Mbps (See 18 Mbps (See Note 2) Note 2)

Typical Office

A (ft.2)

7000

6000

5000

4000

R (ft.)

59

55

50

45

Z (ft.)

84

77

71

63

S (dBm)

-85

-75

-70

-65

A (ft. )

5000

4000

3500

3000

R (ft.)

50

45

42

39

Z (ft.)

71

63

59

55

S (dBm)

-85

-75

-70

-65

A (ft. )

4000

3500

3000

N/A

R (ft.)

45

42

39

-

Z (ft.)

63

59

55

-

S (dBm)

-85

-75

-70

-

A (ft. )

5000

4000

3500

3000

R (ft.)

50

45

42

39

Z (ft.)

71

63

59

55

S (dBm)

-85

-75

-70

-65

A (ft. )

7000

6000

5000

4000

R (ft.)

59

55

50

45

Z (ft.)

84

77

71

63

S (dBm)

-85

-75

-70

-65

Drywall Office Space

Brick Wall Office Space

Hospital

Warehouse/Manufactu ring

2

2

2

2

Note1: S is the minimum signal strength over 95% of the coverage area. Note2: Requires 802.11a.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

7

Page 26

Deployment Determining Deployment Strategy

Voice over IP Requirements When deploying 802.11 wireless LANs to support Voice over IP (VoIP) telephones, such as SpectraLink NetLink Telephones, a few special considerations are needed in the deployment process. When deploying an 802.11b voice system, seamless full coverage with an average user throughput of 5 Mbps or more should be used. Areas such as stairways, bathrooms, cafeterias and outside areas may require special consideration and additional access points. These are areas that are not typically critical for data users but are critical coverage areas for voice users who want seamless coverage.

Determining Deployment Strategy Depending on the customer and the deployment requirements determined in “Determining Deployment Requirements,” there are three strategies for designing and deploying an Cisco WLAN Solution wireless network. The following table provides guidelines for which one is appropriate. Table 5

Deployment Strategy

Deployment Option

Deployment Requirements

Professional Site Survey

This option should be considered when:

RF Prediction with Optional Site Survey

Basic Guidelines with Optional Site Survey

•

Deployments require full coverage with 0% coverage holes.

•

The RF characteristics of the building vary throughout the coverage area.

•

The building type is not typical or does not fit into one of the standard configurations (e.g. Arena, Convention Center, Stock Exchange).

•

The cost or logistics of running Ethernet cables is prohibitive.

This option should be considered when: •

The RF characteristics of the building vary throughout the coverage area.

•

The building type is not typical (e.g. Arena, Convention Center, Stock Exchange).

•

A Professional Site Survey is too costly, and a graphical coverage plot is desired before deployment.

This option is adequate for 80% to 90% of deployments, and is suitable when: •

The RF Characteristics are homogenous throughout the coverage area.

•

The building type can be easily classified.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

8

78-17279-01

Page 27

Deployment Determining Deployment Strategy

Professional Site Survey Generally, the professional site survey involves temporarily placing one or more Cisco 1000 series lightweight access points and then measuring the resulting coverage(s). Based on the results of these measurements, Cisco 1000 series lightweight access points are relocated and/or reoriented to achieve complete coverage of the target space without unnecessary coverage overlap or coverage holes between Cisco 1000 series lightweight access points. This approach is appropriate given the following deployment requirements: •

Full Coverage with 0% coverage holes

•

The RF characteristics of the building vary throughout the coverage area

•

The building type is not typical (Arena, Convention Center, Stock Exchange)

During the Professional Site Survey, one or two access points are placed at or near one end of a building. Their coverage is measured and the access points are relocated and reoriented as necessary to ensure that this end of the building is completely covered. When measurements confirm that this is true, a second or third access point is added so its coverage area somewhat overlaps the coverage area of the first access point(s). (Generally, 10 to 15 percent coverage overlap is considered appropriate.) Its coverage is measured to ensure that its overlap with the first access point(s) is appropriate and to determine the coverage in the rest of the building. This process continues, adding a third or fourth access point and so on. This process continues until all areas of the building are covered. The professional site survey allows the designer to provide full seamless coverage; however, the Radio Resource Management (RRM) ensures that the channel assignments and transmit power levels are optimized for the Cisco WLAN Solution coverage area, freeing the site survey professional from having to fine-tune these variables. Other variables designers may include static transmit power level, geometric pattern used for access point placement, and the antenna type (omnidirectional, wide beam directional, or narrow-beam directional). Some designers like to have the flexibility to select antenna types most suited to specific buildings. Designers may differ in the criteria they use to determine coverage area. Some prefer to use signal strength (RSSI), some prefer signal-to-noise ratio (SNR), and others prefer to use some indication of throughput, such as packet retry rate. These measurements are normally made using site survey software provided by a wireless LAN manufacturer, running on a PC or PDA. They may also be made using one of the handheld measurement tools currently available, such as Air Magnet or Berkeley Varitronics. The measurement tools are usually selected based on their ability to measure the desired variable, RSSI, SNR, or packet retry rates.

RF Prediction with Optional Site Survey RF prediction consists of importing the floor plans of the coverage area into a Computer Aided Design system in which a user can place access points, draw in the walls of the building and assign RF characteristics to the walls. Depending on the confidence level of the estimates made for the building RF characteristics and the cost of filling in potential coverage holes after deployment, an optional site survey may be appropriate to verify assumptions. This approach is appropriate given the following deployment requirements: •

Full Coverage with 2 to 10% coverage holes

•

The RF characteristics of the building vary throughout the coverage area

•

The building type is not typical (Arena, Convention Center, Stock Exchange)

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

9

Page 28

Deployment Example Basic Guidelines Process

Basic Guidelines with Optional Site Survey The Basic Guideline approach is based on empirical data from existing wireless deployments and is adequate for most deployments. This approach is based on most enterprise buildings having common RF characteristics, and that only a part of the building needs to be characterized to verify the access point coverage for the entire building. This approach leverages the algorithms built into the Cisco WLAN Solution Radio Resource Management (RRM) that ensure that the overlap between access points is minimized and that coverage holes are detected and eliminated before clients find them. When deploying 802.11 wireless LANs to support Voice over IP (VoIP) telephones, such as SpectraLink NetLink Telephones, a few special considerations are needed in the deployment process. When deploying an 802.11 voice system, full coverage with an average user throughput of 5 Mbps or more should be used. Areas such as stairways, bathrooms, cafeterias and outside areas may require special consideration and access points. These are areas that are not typically critical for data users but are critical coverage areas for voice users who want seamless coverage.

Example Basic Guidelines Process This section describes the basic factors that you need to consider before deploying access points. Refer to each of the sections below for a detailed explanation: •

Determining the Radius and Z Factor

•

Determining How Many Access Points are Needed

•

Optional Minimal Site Survey

•

Placing Access Points

Determining the Radius and Z Factor This section helps you to determine the coverage area of a Cisco Radio based on the building type and desired average user performance using the table below. The Z factor represents the length of a square that corresponds to the coverage area of the access point.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

10

78-17279-01

Page 29

Deployment Example Basic Guidelines Process

Table 6

Radius and Z Factor Table

Area = Z2 (square ft.)

R (ft.)

Z (ft.)

2500

35

50

3000

39

55

3500

42

59

4000

45

63

4500

47

67

5000

50

71

5500

52

72

Z 6000

55

57

6500

57

81

7000

59

84

7500

61

87

8000

63

89

Coverage Area

135685

R

The following graph displays actual measurements, and shows the relationship between actual user throughput and corresponding signal strength.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points 78-17279-01

11

Page 30

Deployment Example Basic Guidelines Process

The following table includes building types, and shows the coverage area measurements for various average user throughputs. Table 7

Building Type and Average User Throughput

Average User Throughput Building Type

Measurement (Note 1)

1 Mbps

5 Mbps

12 Mbps (See Note 2)

18 Mbps (See Note 2)

Typical Office

A (ft.2)

7000

6000

5000

4000

R (ft.)

59

55

50

45

Z (ft.)

84

77

71

63

S (dBm)

-85

-75

-70

-65

A (ft. )

5000

4000

3500

3000

R (ft.)

50

45

42

39

Z (ft.)

71

63

59

55

S (dBm)

-85

-75

-70

-65

A (ft. )

4000

3500

3000

N/A

R (ft.)

45

42

39

-

Z (ft.)

63

59

55

-

S (dBm)

-85

-75

-70

-

A (ft. )

5000

4000

3500

3000

R (ft.)

50

45

42

39

Z (ft.)

71

63

59

55

S (dBm)

-85

-75

-70

-65

7000

6000

5000

4000

59

55

50

45

Z (ft.)

84

77

71

63

S (dBm)

-85

-75

-70

-65

Drywall Office Space

Brick Wall Office Space

Hospital

2

2

2

2

Warehouse/Manufa A (ft. ) cturing R (ft.)

Note1: S is the minimum signal strength over 95% of the coverage area. Note2: Requires 802.11a.

Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points

12

78-17279-01