The text of a manual · part 3 of 3
CPT-720 Portable Terminal User Manual, pages 17 to 22
Pages 17 to 22 of 22
The original document is the PDF (333 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the CipherLab CPT-720
Page 17
Speed
To set CPU running speed. There are five speeds available: Full speed, 1/2 speed, 1/4 speed, 1/8 speed and 1/16 speed; which need about 39mA, 22mA, 12mA, 7mA and 5mA, respectively, during normal operation (without scanning or data transmission). If high-speed operation is not required, selecting low CPU speed will save battery power. Default: Full speed
Auto Off
Set time threshold for auto poweroff when no operation is taking place during that specified period. If this value is set to zero, this function will be disabled. Default: 10 minutes
Power On
There are two possible selections: Program Resume, which starts from the program being used during the last session before the last power-off; and Program Restart, which starts with a new program. Default: Program Resume
3. Reader Reading test
To test the reading performance of the scanner. Following are the default enabled symbologies: Code 39 Industrial 25 Interleave 25 Codabar Code 93 15
Page 18
Code 128 UPCE UPCE with ADDON 2 UPCE with ADDON 5 EAN8 EAN8 with ADDON 2 EAN8 with ADDON 5 EAN13 EAN13 with ADDON 2 EAN13 with ADDON 5 Other symbologies, must be enabled through programming. 4. Battery Main
Show voltage of the main battery power. If the main battery voltage is low, a battery icon (power-low indicator) will be shown on the LCD screen. The available power will be less than 25% of fresh batteries, The terminal will continue to work normally for a short period of time.
Backup
Show voltage of the backup battery.
5. Test Buzzer
To test the buzzer with different Frequency/Duration. Press ENTER key to start the test, then press any key to stop the test.
LCD & LED
To test LCD display and LED indicator. Press ENTER key to start the test, then press any key to stop the test. 16
Page 19
KBD
To test the rubber keys. Press a key and the result will be shown on the LCD display.
6. Download RS-232
To download the user program via RS-232 port. The transmission speed can be up to 115200 bps.
Docking
To download the user program via communication cradle (charger). The transmission speed can be up to 115200 bps.
IR
To download the user program via high speed IR transceiver. The transmission speed can be up to 115200 bps.
IrDA
To download the user program via standard IrDA. The transmission speed can be up to 115200 bps.
7. Version Version Info
To show version information, including Hardware version, Firmware version, Serial Number and Manufacturing Date.
17
Page 20
5.4 Kernel mode Press the 7, 9 and POWER keys simultaneously to enter the System mode, then power off and press 1, 7 and POWER key simultaneously to enter the kernel mode which provides the following services: Program download
To download user program. The download procedure is same as download program in system mode. Please refer to the above section.
Update kernel
To update system kernel. Sometimes the kernel might be changed for improving performance or other reasons. This function allows you to keep the kernel updated. The update procedure is same as download user program, but note that after updating the kernel, please do not power off until the system restart itself.
Test & Calibrate
To perform a burn-in test and adjust the system clock. This function is for manufacturing purpose only.
18
Page 21
6. Troubleshooting a)
Does not power up after pressing POWER key. Ø b)
c)
Does not power up after changing batteries. Ø
Check if the batteries are properly installed.
Ø
If problem persists, try to enter kernel menu by pressing 7, 1 and POWER keys simultaneously.
Ø
If problem persists, call for service.
Battery-low indicator is on, Ø d)
e)
Change the batteries.
Change the batteries.
Cannot download application program from the host to the CPT-720 Portable Terminal or vice versa, via RS-232 port. Ø
Check if the RS-232 cable is plugged tightly, then,
Ø
Check if host communication parameters (COM port, baud rate, data bits, parity, stop bit) match the CPT-720 Portable Terminal's.
Cannot download application program from the host to the CPT-720 Portable Terminal or vice versa, via IrDA port. Ø
Check if the IrDA transceiver tightly connected to host's COM port, then
Ø
Check if host communication parameters (COM port, baud rate, data bits, parity, stop bit) matched portable's.
19
Page 22
Ø f)
Check if the CPT-720 Portable Terminal is properly positioned within the reading range: (5 to 100cm, 30 degree solid angle) of the IrDA transceiver.
Keypad does not work properly, Ø
Turn off the power then press the 7, 9 and POWER keys simultaneously to enter the kernel mode operation.
g)
h)
Ø
From the system menu, select the Test and then its sub-item KBD.
Ø
Perform the key-in test.
Ø
If problem persists, call for service.
Scanner does not scan, Ø
Check if symbologies used are enabled, or
Ø
Check if battery-low indicator is shown on the LCD display. If yes, change the batteries.
Ø
If problem persists, call for service.
Abnormal responses, Ø
Open the battery holder and re-load the batteries.
Ø
Enter system menu by pressing 7, 9 and POWER keys simultaneously.
Ø
Check if the CPT-720 Portable Terminal can have a correct response by performing entering data.
Ø
If problem persists, call for service.
20