The text of a manual · part 2 of 3
CPT-720 Portable Terminal User Manual, pages 9 to 16
Pages 9 to 16 of 22
The original document is the PDF (333 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the CipherLab CPT-720
Page 9
3.2 RS-232 connection & IrDA connection
RS-232 & IrDA connection
IrDA Transceiver
IrDA connection
( coOO0D000 50C 90000 d0 000000 c0000000
RS-232 port
RS-232 Connection
EE al SSR
Page 10
3.3 RF connection
RF connection (up to 32 units)
720 Portable Data Terminal
720 Portable Data Terminal
720 Portable Data Terminal
RF Base
8
720 Portable Data Terminal
Page 11
3.4 RS-485 connection
Scan ESC A
Aipha B
Scan
Scan
Shift C
BS
ESC D
A
Aipha B
Shift
ESC
BS
C
A
F
G
&
,
?
7
8
H
E
F
G
&
'
Space
9
,
?
7
8
J
4 %
5
!
6
K ;
L
I
J
"
4 %
5 !
6
K ;
#
O
2
\
3
M
:
N
1
#
R
0
+
/
*
P
\
3
Q
_
$
:
+
/
*
#
BS
6
D
H
\
3
K ;
+
/
ESC
Aipha B
Shift
BS
C
F
G
&
?
7
8
9
,
D
H
ESC
Aipha
A
B
E
'
I
J
4
%
M
5
!
6
N
1
#
\
Q
_
$
K ; O
2
P
*
3
+
&
/ *
4
"
%
M
G
5
?
!
9
,
6
N
1
#
\
Q
_
$
D
H Space'
K
L
;
"
O
2
P
BS
C
8 J
L
: R
0
Shift
F
7
Space
I
L "
: R
0
A
E
'
Space
9 !
O
2 Q
_ $
Scan
Scan C
G
5 N
1 R
0
,
8 J
4 %
O
2
P Q
_ $
?
7
L " M
N
1 P
Shift
F &
H
'
Space
9
I I
M
Aipha B
D E
E
3
: R
0
+
/ *
RS-232 connection
9
Page 12
4. Software Organization The system software of CPT-720 Portable Terminal consists of three modules: the kernel module, the system module and the application module.
4.1 Kernel module Kernel module is the innermost core of the system. It has the highest security and is always protected by the system. Only the failure of flash memory or improperly power off during system restart after updating kernel will the kernel be destroyed. The kernel module ensures that user can always download their own program even the operating system was crashed by user’s program. It provides the following services: Ÿ Ÿ Ÿ
Program download Update kernel Test & Calibrate
For detail operations, please refer to section 5.4.
4.2 System module The system module provides the following system services Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ
Memory Setting Reader Battery Test Download Version
For detail operations, please refer to section 5.3.
10
Page 13
4.3 Application module The Application module runs on top of the System module. The CPT-720 Portable Terminal is preloaded with an application module that runs upon powering the unit up. The following menu will be shown: Ÿ Ÿ Ÿ Ÿ
Execute Clear Data Transmit Data Download Settings
The arrow keys can be used to select the menu item, and execute it by pressing the ENTER key. The function and meaning of each item are as follows: Execute
Start the data collection process. A new screen appears after Execute is selected and the ENTER key is pressed, showing the following two prompts: Item: Qty: Data can be input from keypad or barcode reader. Pressing the ENTER key after the Quantity has been entered will save the data and the system will show the same prompts until the ESC key is pressed, which will bring back the main menu.
Clear Data
To clear all the transaction data. A submenu will be shown asking to confirm this action. Once executed, the transaction data will be lost and can not be retrieved. To abort this operation, No must be selected when asked to confirm the operation or by pressing the ESC key to go back to the main menu. 11
Page 14
Transmit Data To upload transaction data to the host PC. There are three ways to transmit the data: via RS-232 or Infrared or standard IrDA. Note: terminal COM port settings should match the host PC settings. Download Settings To download the menus and form prompts for the data collection process. The settings should be configured in the Application Generator, then downloaded to the terminal. The Application Generator allows to define menus and data input forms. For detail operation, please refer to the Application Generator's Operation Guide.
4.4 Build your own application module There are three software tools available for developing application programs. 1. 2. 3.
The Application Generator The “BASIC” Compiler The “C” Compiler
For more information, please contact CipherLab USA or Syntech Information Co., Ltd.
12
Page 15
5. Operations Batteries must be fresh and properly loaded before start operation.
5.1 Keypad operations The keypad of CPT-720 Portable Terminal consists of 32 rubber keys and one power switch. The functions of some special keys are as follows: BS
Back Space. If pressed down longer than one second, a clear code will be sent.
Shift
Shift (toggle key) When it is in shift mode, an uparrow icon will be shown in the screen. Alphabet input will be small letter and F8 can be used to turn on/off the display back-lit. Also the F6 and F7 can be used to adjust the display contrast.
Alpha
The toggle key for Alphabet / Numeral input. When the system is in alpha-mode, a small icon will be shown on the right most side of the display.
ESC
Escape. Usually this key is to exit current operation.
POWER
Power On/Off. To prevent a faulty push, it needs about 1.5 sec continuous pressing to turn On/Off the power. 13
Page 16
5.2 Application mode This is the default operation mode when turning on the power. The operation depends on the application module. Please refer to section 4.4.
5.3 System mode When pressing the 7, 9 and POWER keys simultaneously, the system will enter the System Mode with which provides the following services: 1. Memory Size Information
Includes the SRAM (Data memory) size, extended memory size (SmartMedia Card) and FLASH (Program memory) size in kilobytes.
Initialize
To initialize the data memory (RAM). Note that the contents of the data space will be wiped out after memory initialization.
Test
To test the data memory. For 256 KB SRAM, it takes about 15 seconds to finish the test. Note that the contents of the data space will be wiped out too after memory test.
2. Setting Clock
To set new date and time.
Backlit
To set the intensity of LCD backlight and the duration for staying on. Default: High intensity, the lights go off after 20 seconds.
14