The text of a manual · part 3 of 4
User's Manual 1067/1090/1021+ CCD Scanner, pages 17 to 24
Pages 17 to 24 of 32
The original document is the PDF (75 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the CipherLab 1067 / 1067M
Page 17
• Checksum Verification : This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read. • Checksum Transmission : This parameter specifies whether the checksum character are included in the data being transmitted. • Code Length Qualification : Because of the weak structure of the 2 of 5 codes, a partial scan has a high probability of decoding as a valid but shorter 2 of 5 codes (known as short scan). To prevent this kind of undesired reading, the Code Length settings can help to insure that the correct code is read by qualifying the allowable code length. Code length parameters can be configured in two ways : Fixed Code Length or Max / Min code length. If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the min length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified. • Read Odd Number of Digits : This parameter is available only to the Interleave 25. This parameter must be enabled in order to read Interleave 25 labels which contain odd number of digits.
4.4 Codabar • Start/Stop Transmission : This parameter specifies whether the start/stop characters of Codabar are included in the data being transmitted. • Start / Stop Selection : Four different start / stop pairs can be selected as start / stop characters as listed below. abcd / abcd abcd / tn*e ABCD / ABCD
13
Page 18
ABCD / TN*E • CLSI Conversion : If this parameter is enabled, the scanner will perform the CLSI conversion when a 14 digits Codabar barcode is read.
4.5 UPCE • System Number Selection : The UPCE comes with 2 flavors : System Number 0 and System Number 1. These two differ in the way data are encoded. The system number 1 is the new UPCE extension to the ordinary UPCE (system number 0). User can have the choice of enabling both system numbers or just system number 0. Warning : Because of the way system number 1 is encoded, if both system numbers are enabled, user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes. • Convert to UPCA : If this parameter is enabled, the UPCE read will be expanded into UPCA, and the following processing will follow the parameters configured for UPCA. • System Number Transmission : If this parameter is enabled, the system number will be included in the data being transmitted. • Checksum Transmission : If this parameter is enabled, the checksum character will be included in the data being transmitted.
4.6 EAN8 • Convert to EAN13 : If this parameter is enabled, the EAN8 read will be expanded into EAN13, and the following processing will follow the parameters configured for EAN13. • Checksum Transmission : If this parameter is enabled, the checksum character will be included in the data being transmitted.
4.7 UPCA
14
Page 19
• Convert to EAN13 : If this parameter is enabled, the UPCA read will be expanded into EAN13, and the followi ng processing will follow the parameters configured for EAN13. • System Number Transmission : If this parameter is enabled, the system number will be included in the data being transmitted. • Checksum Transmission : If this parameter is enabled, the checksum character will be included in the data being transmitted.
4.8 EAN13 • ISBN / ISSN Conversion : If these parameters are enabled, the scanner will convert the code read into ISBN or ISSN code if the formats are correct (EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN). • Checksum Transmission : If this parameter is enabled, the checksum character will be included in the data being transmitted.
4.9 MSI • Checksum Verification : Three kinds of checksum calculations can be implemented into MSI code : Single Modulo 10, Double Modulo 10, or Modulo 11 & 10 checksum. If the checksum character is incorrect, the barcode will not be read. • Checksum Transmission : User can control how the checksum is transmitted by configuring this parameters. 1) Transmitted 2) Last digit not transmitted 3) Last 2 digits not transmitted • Code Length Qualification : Because of the weak structure of the MSI code, a partial scan has a high probability of decoding as a valid but shorter MSI codes (known as short scan). To prevent this kind of undesired readings, the Code Length settings can help to ensure that the correct code is read by qualifying the
15
Page 20
allowable code length. Code length limitations can be set in 2 ways : Fixed Code Length and Max / Min code length. If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the min length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified.
4.10 Plessey • Convert to UK Plessey : If this parameter is enabled, the scanner will change each occurrence of the character ‘A’ into character ‘X’ in the code. • Checksum Transmission : If this parameter is enabled, the checksum characters (two characters) will be transmitted together wi th data.
16
Page 21
5. Data Output Format Data read by the scanner will be processed in the following sequence (RS-232 and Keyboard Wedge interfaces only). 1) The character substitution is performed on the barcode data. 2) The Code ID and the Length Code are inserted at the beginning of the data as shown below. [Code ID] [Length Code] [Data] 3) The resulting data of step 1 will be processed by the editing formats. For details, please refer to the section “Data Editing”. 4) And finally the Prefix Code and the Postfix Code will be added before transmission. [Prefix Code] [Resulting Data of Step 3] [Postfix Code]
5.1 Character Substitution There are three character substitution settings on the scanner. These settings are configured on a character base. That is, a specific character is to be substituted by an another character. The character substitution is performed on every occurrence of the characters specified in these settings. Be aware, the substitution is performed only on the barcode itself (exclude Prefix Code, Postfix Code, Code ID, Length Code or any Additional Field) and is performed before editing mode processing. If only the character to be replaced is specified, every occurrence of that character in the barcode will be taken away.
5.2 Prefix / Postfix Code Up to four characters of prefix / postfix code can be configured for the scanner.
5.3 Code ID Up to two characters of Code ID can be configured for each symbology. To minimize the Code ID configuration efforts, the scanner provides five predefined Code ID Sets that user can select from. User can first select one of the Code ID Sets and then
17
Page 22
make desired modifications. The pre-defined Code ID Sets are shown below.
Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codabar Code 93 Code 128 UPCE EAN8 EAN13 MSI Plessey UPCA
Set 1 Set 2 Set 3 Set 4 Set 5 A C Y M A A C Y M A A C Y M A C H H H S D I Z I S E G G G S F N X N F I L L L G H K K K C S E C E E P B B FF E M A A F E V V D P M W W E Q P M A A F E
5.4 Length Code Two digits Length Code representing the length of data (character count) can be inserted in front of data being transmitted. This Length Code parameter can be individually enabled or disabled for each barcode symbology.
18
Page 23
6. Data Editing The 1067/1090/1021+ CCD scanner provides advanced data editing functions for data formatting. Data editing is performed according to user configured editing formats. Up to three editing formats can be configured. Data is divided into fields by user specified rules. These fields together with user configurable additional fields constitute the data actually sent to the host computer. The detailed descriptions and the configuration procedures of the editing format are described in this section.
6.1 Select Editing Format To start configuring an editing format, the editing format to be configured must first be selected. Once it is selected, the parameters pertaining to editing format (applicable condition, total number of field, field dividing rules, additional fields, and field transmission sequence parameters) can be configured. After all the desired parameters are configured, the “End of Format Programming” label must be read to complete the configuration of that editing format. Note : Before completing the configuration of the editing format, if parameters other than those pertaining to editing format are read, the editing format under configuration will be aborted. User must restart the configuration again by selecting editing format to be configured.
6.2 Restore Default Format After the editing format to be configured is selected, user can read the “Restore Default Format” label to put the editing format back to default setting. The default settings of the editing format are listed below. • Applicable Code Type : All • Applicable Length : Both max and min length are zero. • Matching string : Empty • Matching String Location : 0 • Total number of field : 1 • Field Setting : Not Configured
19
Page 24
• Additional Fields : Empty • Field Transmission Sequence : F1
6.3 Applicable Conditions Three applicable conditions can be configured to qualify whether the data read by the scanner can be processed by the particular editing format. Data editing will not be performed unless all three applicable conditions are met The configurable applicable conditions are described below. • Code Type : This parameter specifies the code type of the data eligible for data editing. Multiple code types can be specified for this parameter. • Data Length : This parameter specifies the length (character count) of the data eligible for data editing. It is specified in the range format. The length of the data must fall between max and min length limits. If the max length and the min length configured is both zero, the scanner will not perform this length qualification. • Matching String and its Location : User can specify a particular character string (up to four characters) that must appear in the data which is eligible for data editing. User can also specify where (character position, starts from one) this string should appear in the data by configuring the matching string location. If the location specified is zero, the scanner only checks for the existence of the matching string in the data. To disable the matching string qualification, just leave the matching string empty.
6.4 Total Number of Fields Data can be divided into at most 6 fields. The total number of fields configured must be correctly specified. The fields are numbered from F1 to F6 accordingly, but only F1 to F5 can be configured. Please note that, the number of fields can be configured is always one less than total number of fields specified. The extra data characters beyond the
20