Page 25

last field configured will be automatically assigned to the next field. That is, if three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats.

6.5 Dividing Data into Fields Data eligible for editing format is divided into fields according to user specified rules. The rule for each field can be configured in two ways. • Field Terminating String : The field dividing rule can be configured by specifying the field terminating string. The field terminating string configured can be up to two characters. The scanner will search for the occurrence of this particular string in the data for the field. The field terminating string is always included in the field. User though, has the option of discarding this terminating string. • Field Length : The field dividing rule can be configured by simply specifying the field length. The scanner will assign the next specified number of characters into the field.

6.6 Additional Fields User can create up to five additional fields for each editing format. Each additional field can have at most four characters. The additional fields are numbered AF1 to AF5 accordingly.

6.7 Field Transmission Sequence After the data fields and the additional fields are configured, user can now program the transmission sequence of these fields that comprise the final data. The “Start” label must be read before assigning the field transmission sequence. And then the desired field transmission sequence can be specified. The scanner will transmit the fields in the order (sequence) user programmed when sending data. The field transmission sequence can be assigned in any desired order and fields can also be assigned multiple times. The maximum number of fields can be assigned

21

Page 26

is twelve. After the sequence has been assigned, the “End” label must be read to complete the setting.

6.8 End of Format Programming After all the desired parameters are configured, the “End of Format Programming” label must be read to conclude the programming of the editing format. This label is located at the bottom of every even page in the “Editing Format Parameters” section of the configuration manual.

6.9 Activate Data Editing Formats Before data can be processed by a particular editing format, that format must be enabled. The editing formats can be enabled or disabled individually.

6.10 Exclusive Data Editing If this parameter is enabled, all data read by the scanner must be processed by the editing format. If the data is not eligible for all enabled editing formats, the scanner will not accept the reading and the data will not be transmitted.

6.11 Programming Examples Example 1 : Extracts data from the 10th character to the 19th character. Total Number of Fields : 3 Field 1 : Divide field by field length, set field length to 9 Field 2 : Divide field by field length, set field length to 10 Field Transmission Sequence : F2 Example 2 : Extract the date code, item number, and quantity information from barcodes. Data is encoded in the barcode like this : From the first character to the 6th character is the date code. From the 7th character is the item number, its length is not fixed but is delimited by a ‘-’ character. After the ‘-’ character is the quantity information.

22

Page 27

Data should be transmitted like this : Item number goes first, then a TAB character, and then the date code, and then another TAB character and finally the quantity. Total Number of Fields : 3 Field 1 : Divide field by field length, set the field length to 6. Field 2 : Divide field by field terminating string. Set terminating string to ‘-’, and discard the terminating string. Additional Field 1 : Set to one TAB character. Field Transmission Sequence : F2 AF1 F1 AF1 F3

23

Page 28

7. Configuring 1067/1090/1021+ Configuring the 1067/1090/1021+ CCD Scanner is done by reading the setup labels contained in the Configuration Manual (the second part of this manual). This section describes the procedure of configuring the scanner. Some configuration examples are also given in this section for illustration.

7.1 Enter Configuration Mode To start the configuration, the “Enter Setup” label must be read. This will put the scanner in the configuration mode. The scanner will respond with 6 beeps and the indicator will turn green after the label is read. This “Enter Setup” label is located at the bottom of almost every even page of the Configuration Manual.

7.2 Default All the parameters of the scanner will return to their default values by reading the “Default” label. The scanner will beep twice when the “Default” label is read.

7.3 List Setting The current setting of all scanner parameters can be sent to the host computer for user inspection. The listing is separated into ten pages. User can select the page of interest by reading the “Page x” label. The scanner can not list setting, if Wand Emulation interface is configured. Page 1 : Interface, Buzzer, and Scanner Parameters Page 2 : Prefix, Postfix, and Length Code Setting Page 3 : Code ID Page 4 : Readable Symbologies Page 5 : Symbology Parameters (1/3) Page 6 : Symbology Parameters (2/3) Page 7 : Symbology Parameters (3/3) Page 8 : Editing Format 1 Page 9 : Editing Format 2 Page 10 : Editing Format 3

24

Page 29

7.4 Setting Parameter Values For most of the parameters, only one reading is required to set them to new values. The scanner will respond with two beeps when these parameters are configured. But for some special parameters, multiple readings are required to complete the setting. The scanner will respond with a short beep if the configuration of the parameter is still not complete. These parameters usually refer to a numeric value or a string of characters, such as keyboard type, intercharacter delay, prefix / postfix code, etc.. For these kinds of parameters, the label of the parameter to be configured must be read first. And then, the labels comprising the numeric value or character string are read. And finally, the “Validate” label must be read to complete the setting. The scanner will respond with two beeps when the “Validate” label is read. 7.4.1 Numeric Parameters The configuration procedures for numeric parameters are shown below. Parameter Label

Decimal Label

"Validate" Label For example, to configure the Inter-Character Delay to be 15 ms, the “Inter-Character Delay” label is first read, and then the decimal digit labels “1” and “5”, and finally, the “Validate” label to complete the setting.

25

Page 30

7.4.2 Character String Parameters Basically, each character programmed for the character string parameters is represented by two hexadecimal digits. The two hexadecimal digits usually comprise a value which is the ASCII code equivalence of the character being programmed. Beside the two hexadecimal digits, there is an optional key type/status can also be specified for each character of the string parameters. This optional key type/status can only be specified for some particular parameters when keyboard interface is used. These parameters are : Prefix Code, Postfix Code, Code ID, and Additional Fields of Editing Formats. The available key type/status settings can be selected will be described briefly. The configuration procedures for character string parameters are shown below. Parameter Label

Key Type / Status Label

Two Hexadecimal Labels

"Validate" Label For example, to configure the Prefix Code to be “AB”, the “Prefix Code” label is first read, and then the hexadecimal digit labels “4”, “1”, “4”, and “2” are read, and finally, the “Validate” label to complete the setting. 7.4.3 Key Type/Status Setting

26

Page 31

The key type/status is specified in character basis. Each character programmed is by default of Normal key type. A character of normal key type can have associate status settings (add Shift/Control/Alternate). Whereas a character of Scan Code type may not have any associate key status settings. • Normal Key Type: When this label is read, the scanner will assume the following hexadecimal digits are the ASCII code of the character being programmed. And it will also clear all the associate key status settings made to the current character. • Scan Code : When this label is read, the scanner will assume the following hexadecimal digits are the scan code value of the character being programmed. • Add Shift : The Shift key will be sent together with the character programmed. • Add Control (L) : The left Control key will be sent together with the character programmed. • Add Alternate (L) : The left Alternate key will be sent together with the character programmed. • Add Control (R) : The right Control key will be sent together with the character programmed. • Add Alternate (R) : The right Alternate key will be sent together with the character programmed. For example, to program the Prefix Code to be “CtrlShift-B”, “C”, the programming sequence should be : 1) “Prefix Code” label 2) “Add Control (L)” label 3) “Add Shift” label 4) “4” of the hexadecimal digit 5) “2” of the hexadecimal digit 6) “4” of the hexadecimal digit 7) “3” of the hexadecimal digit 8) “Validate”

27

Page 32

Note : In internal representation of the characters which are specified with either scan code or associate key status, occupy two normal character space each. So the maximum number of characters can be configured for a string parameter will decrease, if these character specifications are used.

7.5 Exit Configuration Mode Both the “Update”, and the “Exit Setup without Changes” labels will exit the scanner from configuration mode when they are read. These two labels differ in whether to keep the new settings on the scanner or not, as their names suggest. The scanner will respond with 6 beeps and restart itself, if either label is read.

28