Page 9

• Code 39 (Standard / Full ASCII) • Italy Pharmacode • French Pharmacode • Industrial 25 • Interleave 25 • Matrix 25 • Codabar (NW-7) • UPCA (with or without Addon) • UPCE (with or without Addon) • EAN8 (with or without Addon) • EAN13 (with or without Addon) • Code 93 • Code 128 • EAN 128 • MSI • Plessey

2.8 Negative Barcodes The CCD scanner can be configured to read negative barcodes. Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of the negative barcodes are printed with a color darker than that of the bars.

5

Page 10

3. Output Interface The 1067/1090/1021+ is a multi-interface CCD scanner. It can be configured as a keyboard wedge scanner, an RS-232 scanner, or a Wand emulation scanner. The output interface can be easily changed simply by replacing appropriate interface cable and configuring the desired interface type.

3.1 Keyboard Wedge Interface 3.1.1 Keyboard Type The keyboard wedge interface is enabled by configuring/selecting keyboard type. The supported keyboard types are listed below. • PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium, Spanish, and Portuguese KBD • PCXT • PS2-30 • PS-55 • IBM 5550 • IBM 3477 TYPE (Japanese KBD) • IBM 34XX,319X & Memorex Telex (122Keys) • Wyse Enhance KBD (US, French) • DEC VT220,320,420 • Macintosh (ADB) • Hitachi Elles • NEC 5200 • NEC 9800 • NEC Astra • Unisys TO-300 • Televideo 965 • ADDS 1010 3.1.2 Keyboard Style - Alphabets Keyboard layout style can be selected. There are three options to this setting : default layout (US or English style), AZERTY layout, and QWERTZ layout. This setting only works when the keyboard type selected is for US keyboard. The scanner will make necessary

6

Page 11

adjustment when sending the ‘A’, ‘Q’, ‘W’, ‘Z’, ‘Y’, and ‘M’ character according to this setting. 3.1.3 Keyboard Style – Digits There are two digit layout styles as shown on the following figures. One has its digit keys on top (upper row), the other has them on bottom (lower row). The digit layout style can be changed by configuring this setting. There are three options to this setting : Default, Lower Row, and Upper Row. The scanner will make necessary adjustment when sending digits according to the setting value of this parameter. This setting is meant to be used with the above setting (Keyboard Style – Alphabets) and perhaps Character Substitution setting, when support to languages not available on the scanner is needed. ! 1

@ 2

# 3

$ 4

Digits on Lower Row

1 !

2 @

3 #

4 $

Digits on Upper Row

3.1.4 Capital Lock Status In order to send alphabets with correct case, the scanner needs to know the capital lock status of the keyboard. Incorrect settings may result in reversed case of alphabets being transmitted. There are 3 options to this parameter : On, Off, or Auto Detection. If this parameter is set to Auto Detection, the scanner will automatically detect the capital lock status of the keyboard before it transmits data. But the Auto Detection option is supported only when the keyboard type configured is either PCAT (all available languages), PS2-30, PS55, IBM 34XX/319X, or Memorex Telex.

7

Page 12

3.1.5 Alphabets Transmission User can choose how alphabets are sent by configuring this parameter. The alphabets can be sent according to their case (the Case Sensitive option), or the case is ignored (the Ignore Case option) when transmitting. 3.1.6 Digits Transmission User can choose how the scanner transmits digits by configuring this parameter. The scanner can transmit digits by using the alphanumeric key or by using the numeric key pad. The Num Lock status of the keyboard should be ON if numeric key pad option is selected. Numeric Key Pad

Keyboard AlphaNumeric Key 3.1.7 Inter-Character Delay An inter-character delay of 0 to 255 ms can be configured to match the computer response time of the keyboard interface. The delay time configured is inserted between transmitting every character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

8

Page 13

3.2 RS232 Interface The RS-232 interface is enabled by reading the “Activate RS-232 Interface” label in configuration mode. User can select the desired transmission mode, flow control, baud rate, parity, and data bits to be used in this output interface. 3.2.1 Transmission Mode There are four transmission modes supported on the scanner when RS232 output interface is used. One of them is for single port operation, and the others are for dual port operation. Single port operation is used where the scanner is connected directly to the host computer, whereas the dual port operation is used where the scanner is connected between host and terminal. The interface cable for dual port operation always has two connectors, one of them is a male connector and the other one is a female connector. Under dual port operation, user can select whether data are transmitted to either ends or are transmitted to both ends. The supported transmission modes are listed below. • Single Port • Dual Port - Data are transmitted to male connector end. • Dual Port - Data are transmitted to female connector end • Dual Port - Data are transmitted to both ends. 3.2.2 Baud Rate / Parity / Data Bits The supported baud rate, parity, and data bit are listed below. • Baud Rate : 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 300 / 110 • Parity : None / Even / Odd • Data bit : 8 / 7 3.2.3 Flow Control If the single port transmission mode is selected, user can further configure the flow (handshake) control method to be used. The available options are listed below.

9

Page 14

• No Flow Control • Scanner Ready : The scanner will activate the RTS signal after power on. After each good read the scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active. • Data Ready : The RTS signal will be activated after each good read. The scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active. • Inverted Data Ready : It is like the Data Ready flow control, but the RTS signal level is inverted. 3.2.4 Inter-Character Delay An inter-character delay of 0 to 255 ms can be configured to match the computer response time. The delay time configured is inserted between transmitting every character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

3.3 Wand Emulation The Wand Emulation output interface is enabled by reading the “Activate Wand Emulation” label in configuration mode. User can select the signal levels of the normal status and bar status to be used in this output interface. 3.3.1 Normal Status This setting specifies the signal level of the normal state when not transmitting a barcode image. 3.3.2 Bar Status This setting specifies the signal level used to represent a bar when transmitting a barcode image.

3.4 PC Term Mode The PC Term mode is enabled by reading the “Activate PC Term” label in configuration mode. The user can select US style keyboard or French style keyboard depends on which activation label is read.

10

Page 15

User can then select the desired baud rate, parity, and data bits to be used in this output interface. The InterCharacter Delay and Capital Lock Status settings can also be configured.

11

Page 16

4. Symbology Parameters This section describes user configurable parameters which are pertaining to barcode symbologies.

4.1 Code39 • Standard / Full ASCII Code 39 : User can choose to read either Standard Code 39 or Full ASCII Code 39 by configuring this parameter. • Start/Stop Transmission : This parameter specifies whether the start/stop characters of Code 39 are included in the data being transmitted. • Checksum Verification : This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read. • Checksum Transmission : This parameter specifies whether the checksum character are included in the data being transmitted.

4.2 Italy / French Pharmacode For Italy /French Pharmacode, there is always a checksum character included in the barcode. So the checksum verification is always performed when decoding these symbologies. User though can choose whether the checksum character is to be transmitted or not. The start / stop transmission of this code shares the same setting of Code 39. • Checksum Transmission : This parameter specifies whether the checksum character are included in the data being transmitted.

4.3 Industrial / Interleave / Matrix 25 • Start / Stop Selection : This parameter provides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 25 barcode but with Interleave 25 start / stop. In order to read this barcode, the start / stop selection parameter of Industrial 25 should set to ‘Interleave 25.