Page 118

Power On Setup Functions

Power On Setup

Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.2.3 Orient Use this function to change the orientation of the terminal display to match the physical terminal orientation. If the terminal is turned so that the longest dimension is vertical, select “portrait”; if the longest dimension is horizontal, select “landscape.” Press [Next] or [Back] to move to DISPLAY. Press [Select] and [Next] to move to Orient, and press [Select] again to move to the options. Press [Next] or [Back] to select Portrait or Landscape. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.2.4 Touch Use this function to enable or disable the touch screen functionality on terminals with touch screens (this item will not appear in Power On Setup if the terminal does not have a touch screen). Press [Next] or [Back] to move to DISPLAY. Press [Select] and [Next] to move to Touch, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.2.5 DCache In applications where many objects are layered on top of each other, you may see a small latency when the screen updates. Draw caching stores objects in memory to improve display performance but does require more RAM to function. There are currently four different levels of drawcaching supported (listed in order of amount of memory used).

106

Off no objects are cached

Effective Enabled only objects that are enabled and whose parents are enabled back to root are cached

Enabled all enabled objects are cached

All all objects are cached

Qlarity-Based Terminal Hardware

Page 119

Power On Setup

Power On Setup Functions

Press [Next] or [Back] to move to DISPLAY. Press [Select] and [Next] to move to DCache, and press [Select] again to move to the options. Using [Next] and [Back], select the level of draw caching desired. Press [Select] to return to the function name.

8.4.3 Calibration The Calibration functions are used to calibrate the terminal to the air temperature and to calibrate the touch screen if it is not working properly.

8.4.3.1 Temp A default temperature is set at the factory. If there is more than a 5 °Celsius difference between the default temperature shown and the surrounding air temperature, you may want to change this setting. This parameter is used in the terminal to help with display contrast compensation. Press [Next] or [Back] to move to CALIBRATION. Press [Select] to move to Temp, and press [Select] again. Press [Next] or [Back] until the correct temperature is displayed, then press [Select] to return to the function name. NOTE

☞

The temperature sensor in the QTERM-G55 does not require calibration. Therefore, the current temperature is shown, but it cannot be modified with the [Next] or [Back] key. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.3.2 Date This function is used to set or change the real-time clock’s date (if the real-time clock is available). Press [Next] or [Back] to move to CALIBRATION, and press [Select] to move to Date. Then change the day, date, month, and year, as follows. Press [Select] again to move to the “day of the week” field, and press [Next] or [Back] to change the day. The date is entered in a two-digit field (01, 02, 10, etc.). Press [Select] to move to the first digit in the “date” field, and press [Next] or [Back] to change the digit. Press [Select] to move to the second digit in the “date” field, and press [Next] or [Back] to change the digit. Press [Select] to move to the “month” field, and press [Next] or [Back] to change the month. The year is entered in a two-digit field. Press [Select] to move to the first digit in the “year” field, and press [Next] or [Back] to change the digit. Press [Select] to move to the second digit in the “year” field, and press [Next] or [Back] to change the digit.

Qlarity-Based Terminal Hardware

107

Page 120

Power On Setup Functions

Power On Setup

Press [Select] at the last digit to return to the function name. The date is immediately changed. NOTE

☞

If you are using a keyboard, you can use the number keys (0–9) to enter the digits. If you are using a terminal with a keypad (24- or 40-key with standard Beijer Electronics legend), you can use the number keys (0-9) to enter the digits. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.3.3 Time This function is used to set or change the real-time clock’s time. Press [Next] or [Back] to move to CALIBRATION, and press [Select] to move to Time. Then enter the hour, minutes, and seconds in 24-hour (or military) time (e.g., 13:10:25 for 1:10:25 p.m.) as follows. Press [Select] to move to the first digit in the “hour” field, and press [Next] or [Back] to change the digit. Press [Select] to move to the second digit in the “hour” field, and press [Next] or [Back] to change the digit. Press [Select] to move to each digit in the “minutes” field, and press [Next] or [Back] to change the digits. Press [Select] to move to each digit in the “seconds” field, and press [Next] or [Back] to change the digits. Press [Select] at the last digit to return to the function name. The time is immediately changed. NOTE

☞

If you are using a keyboard, you can use the number keys (0–9) to enter the digits. If you are using a terminal with a keypad (24 or 40 key with standard Beijer Electronics legend), you can use the number keys (0-9) to enter the digits. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.3.4 Touchscreen You will only see this function if you are using a touch screen-based terminal. If the touch screen is not working properly, you can use this function to calibrate it. NOTE

☞

You can also calibrate the touch screen without entering the Power On Setup utility (see section 8.5). Press [Next] or [Back] to move to CALIBRATION. Press [Select] and [Next] to move to Touchscreen, and press [Select] again. The message, “TOUCHSCREEN CALIBRATION, Please press center of cross” is displayed, and a “+” symbol appears on the screen.

108

Qlarity-Based Terminal Hardware

Page 121

Power On Setup

Power On Setup Functions

Press the “+” symbol. The symbol moves to the bottom of the display. Press the “+” symbol in its new location. This completes calibration. When finished, the terminal returns to Power On Setup. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.4 Network This function is only seen if your terminal has the optional Ethernet communications port. Use this function to enter network addresses for the Ethernet port. If you do not know the network addresses, consult your network administrator. Press [Next] and [Back] to move to NETWORK. Press [Select] and [Next] to move to DHCP or the desired address field. For DHCP, press [Select] to move to the options, then press [Next] or [Back] to select On or Off. Press [Select] to return to the function name. For the address fields, press [Select] at the desired field to move to the first digit of the address. Press [Next] or [Back] to change the digit’s value. Press [Select] to move to the next digit and press [Next] or [Back] to change it. Continue to press [Select] and change each digit in the address as required. Press [Select] at the last digit to return to the function name. NOTE

☞

If you are using a keyboard, you can use the number keys (0–9) to enter the digits. If you are using a terminal with a keypad (24 or 40 key with standard Beijer Electronics legend), you can use the number keys (0-9) to enter the digits. DHCP: On | Off Enable or disable Dynamic Host Configuration Protocol. DHCP allows the unit to obtain its network configuration (IP address, subnet mask, gateway) dynamically from a server on the local area network. When DHCP is turned on, the address fields will disappear. They will re-appear when DHCP is turned off. There may be a short delay while the unit updates the network settings when DHCP is turned on. IP: xxx.xxx.xxx.xxx Enter the terminal’s IP address. Sub: xxx.xxx.xxx.xxx Enter the subnet mask. Gate: xxx.xxx.xxx.xxx Enter the IP address of the gateway (default route). Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

Qlarity-Based Terminal Hardware

109

Page 122

Power On Setup Functions

Power On Setup

8.4.5 Wireless This function is only seen if your terminal has the optional 802.11b/g wireless Ethernet interface. Use this function to enter the service set and connection type information for the wireless network which your terminal will connect to. If you do not know this information, consult your network administrator. Press [Next] and [Back] to move to WIRELESS. Press [Select] to enter the submenu, then press [Next] to move to the desired field. SSID: <string, 24 characters or less> Press [Select] with “SSID” highlighted to begin entering the new 802.11 Service Set Identifier. Press [Next] and [Back] to cycle through the alphanumeric characters. Press [Select] to select the highlighted character and move to the next character. To terminate entry after all desired characters in the string are entered, press [Next] until the termination symbol <> is displayed, then press [Select]. The Power On Setup SSID entry method supports alphanumeric characters only. If the SSID must contain other characters, the SSID must be set by the application (see the online documentation for the SetSystemSettings() API function). Net Type: Infra | Ad Hoc This item is used to select Infrastructure or Ad Hoc mode for wireless communications. Press [Select] with “Net Type” highlighted, then press [Next] or [Back] to select the desired mode. Press [Select] to complete selection. Chan: This item is used to select the 802.11 channel for wireless communications. This value is only important if the interface is to be used in Ad Hoc mode. Press [Select] with “Chan” highlighted to begin channel selection. Press [Next] or [Back] to cycle through the available channels until the desired setting is displayed. Then press [Select] to complete selection. Region: This item is used to select the geographical region where the 802.11 wireless interface will be used, as the channel frequencies vary by region. Due to current agency certification limitations, only the North American region is supported at this time.

8.4.6 Security This function is only seen if your terminal has the optional 802.11b/g wireless Ethernet interface. Use this function to enter the wireless security settings and keys for the wireless network which your terminal will connect to. If you do not know this information, consult your network administrator. Press [Next] and [Back] to move to SECURITY. Press [Select] to enter the submenu, then press [Next] to move to the desired field.

110

Qlarity-Based Terminal Hardware

Page 123

Power On Setup

Power On Setup Functions

Auth: Open | SharedKey | WPA PSK | WPA None | WPA2 PSK This item selects the 802.11 authentication scheme. Press [Select] with “Auth” highlighted to begin selection. Press [Next] and [Back] until the desired scheme is displayed. Press [Select] to complete selection. Encryp: None | WEP128 | TKIP | AES This item selects the 802.11 encryption algorithm. Press [Select] with “Encryp” highlighted to begin selection. Press [Next] and [Back] until the desired algorithm is displayed. Press [Select] to complete selection. WEP Key: 1-4 If WEP encryption is selected, this item allows selection of the WEP key to use for 802.11 communications. The terminal supports up to 4 keys. Press [Select] with “WEP Key” highlighted to begin selection. Press [Next] and [Back] until the desired key number is displayed. Press [Select] to complete selection. WEP Key 1 through WEP Key 4: If WEP encryption is selected, these items are used to set the contents of the WEP Keys. Press [Select] with the desired “WEP Key #” highlighted to begin key setting. The key entry field will be displayed. The keys must be set in hexadecimal format. Press [Next] and [Back] until the desired hexadecimal digit is displayed. Press [Select] to accept that digit and move to the next. Unused digits at the end of the key should be set to 0. Entry will automatically terminate after the last digit has been set. WPA Key: If WPA (TKIP or AES) encryption is selected, this item is used to set the contents of the WPA Key. Press [Select] with “WPA Key” highlighted to begin setting the key. The key entry field will be displayed. The keys must be set in hexadecimal format. Press [Next] and [Back] until the desired hexadecimal digit is displayed. Press [Select] to accept that digit and move to the next. Unused digits at the end of the key should be set to 0. Entry will automatically terminate after the last digit has been set. NOTE

☞

Key lengths must be at least 8 characters (16 hexadecimal digits). WPA keys may be up to 32 characters in length, but the Power On Setup utility only supports setting of 8-16 character keys (up to 32 hexadecimal digits). Longer keys must be set by the application.

8.4.7 COM1 and Any Additional Installed Serial Ports NOTE

☞

If you have an optional secondary serial port, you will also see the “COM2” category. You should configure both COM1 and COM2 as described in this section. Some custom terminals may be configured with up to 10 serial ports. On these units, sections for COM1 through COM10 will appear in the menu. All serial ports are configured in a similar manner. Use the following functions to configure your serial communications port(s).

Qlarity-Based Terminal Hardware

111

Page 124

Power On Setup Functions

Power On Setup

Press [Next] or [Back] to move to COM1 or COM2 (or the desired port). Press [Select] and [Next] to move to each field. Press [Select] at each field to move to the field entry. Press [Next] or [Back] to select the appropriate entry at each field. Press [Select] to return to the function name. Baud Rate: Select the baud rate (600 – 115,200 bps). Data Bits: Select the number of data bits, 7 or 8. NOTE

☞

The serial port must be set to 8 data bits to support user application downloads or firmware upgrades. Parity: Select the parity setting, N (none), O (odd), or E (even). Stop bits: Select the number of stop bits, 1 or 2. Flow Ctrl: Select the type of flow control, None, SW (XonXoff, software), or RTS/CTS (hardware). If using hardware flow control (HW), refer to the pinout table in “Serial Ports” section for the appropriate terminal. Some terminals may also support DTR/DSR (hardware) flow control. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup. TX Timeout: Select the maximum amount of time to wait to send, if flow control is being used, before a transmission error occurs (and thus terminates the transmission). This setting helps to keep the unit from hanging indefinitely while waiting to transmit if communication between the unit and its counterpart breaks down. The timeout is specified in the number of 20 ms ticks to wait. Press [Next] or [Back] to move to the appropriate COM. Press [Select] and [Next] to move to the “TX Timeout” field. Press [Select] again to move to the first digit in the field. Press [Next] or [Back] to change the digit's value. Press [Select] to move to the next digit and press [Next] or [Back] to change it. Continue to press [Select] and change each digit in the TX Timeout as required. Press [Select] at the last digit to return to the Port field.

NOTE

☞

If you are using a keyboard, you can use the number keys (0-9) to enter the digits. If you are using a terminal with a keypad (24 or 40 key with standard Beijer Electronics legend), you can use the number keys (0-9) to enter the digits. Protocol: For terminals equipped with a serial multiport, use this function to select the desired serial protocol (EIA-232, EIA-422, or EIA-485).

112

Qlarity-Based Terminal Hardware

Page 125

Power On Setup

Power On Setup Functions

Press [Select] and [Next] to move to Protocol, and press [Select] again to move to the options. Press [Next] or [Back] to select the desired protocol, then press [Select] to return to the function name. NOTE

☞

The multiport protocol setting will change the signal levels on the serial port pins. To prevent potential damage to equipment, set the protocol setting to the desired level before attaching the terminal to external devices. Termination: For terminals equipped with a serial multiport, this item will appear if the 485 protocol is selected. Use this function to enable or disable the EIA-485 termination network Press [Select] and [Next] to move to Termination, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. Failsafe: For terminals equipped with a serial multiport, this item will appear if the 485 protocol is selected. Use this function to enable or disable the EIA-485 failsafe network, which pulls the signal lines to the passive signal levels when no device is driving the bus. Press [Select] and [Next] to move to Failsafe, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name.

8.4.8 Keypad You will only see this category if your terminal is set up to use a keypad. The Keypad functions are used to turn the keyclick, key repeat and auto shift features on or off. The default state of the keypad backlight (if available) is also set in this section.

8.4.8.1 Keyclick Use this function to turn the audible keyclick on or off. If “on,” you will hear a click when a key on the keypad is pressed. Press [Next] or [Back] to move to KEYPAD. Press [Select] to move to Keyclick, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.8.2 Key Repeat Use this function to turn the key repeat feature on or off. If “on,” a key entry repeats if you hold down the key on the keypad.

Qlarity-Based Terminal Hardware

113

Page 126

Power On Setup Functions

Power On Setup

Press [Next] or [Back] to move to KEYPAD. Press [Select] and then [Next] to move to Key Repeat, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off. Press [Select] to return to the function name. If you selected On, you will see two additional functions, as described in the following sections. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.8.3 Rpt Delay You will only see this function if you selected On at the “Key Repeat” field (see section 8.4.8.2). Use this function to select the delay time that you want between when a key is pressed and when it begins to repeat automatically. Press [Next] to move to Rpt Delay, and press [Select] to move to the options. Press [Next] or [Back] to select the key repeat delay time in milliseconds. The time increments or decrements by 20 ms each time you press [Next] or [Back]. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.8.4 Rpt Rate You will only see this function if you selected On at the “Key Repeat” field (see section 8.4.8.2). Use this function to select the time that you want between each repeat when a key begins to repeat automatically. Press [Next] to move to Rpt Rate, and press [Select] to move to the options. Press [Next] or [Back] to select the key repeat rate in milliseconds. The rate increments or decrements by 20 ms each time you press [Next] or [Back]. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.8.5 AutoShift When AutoShift is enabled, the system software will automatically handle the Shift function of the keypad, i.e., when the Shift key is pressed, the Shift LED is lit and subsequent key presses will return shifted key codes to the Qlarity application. Set AutoShift to Off to disable this automatic shift behavior. When AutoShift is disabled, pressing the Shift key will generate normal key messages, and the Shift LED may be manipulated using the SetLED API. Press [Next] to move to AutoShift, then press [Select] to move to the options. Press [Next] or [Back] to select On or Off. Press [Select] to return to the function name.