Page 109
CHAPTER 8
POWER ON SETUP The Power On Setup utility is used to set up or change the operation settings of the terminal. Power On Setup includes functions to do the following:
• Download new firmware to the terminal • Download user applications to the terminal • Select the application mode • Set communications settings for the terminal • Adjust display settings (contrast, backlight, orientation) • Enter network (Ethernet) settings • Enter/change password (if used) • Perform touch screen calibration (touch screen-based terminals only) • Set the real-time clock Most of these parameters can also be accessed and changed by the application at runtime. Refer to the Qlarity Foundry online documentation for the GetSystemSetting( ) and SetSystemSetting( ) API functions. The method of entering the Power On Setup utility varies depending on whether you use a touch screen, a keypad or a keyboard. Instructions are provided for each type of input device in the following sections.
8.1 Using a Touch Screen The touch areas used to enter the Power On Setup utility and calibrate the touch screen are not shown on the screen. However, after you enter the Power On Setup utility, the touch keys used to perform the functions are shown on the screen, with the exception of the QTERM-G58 (see the note on page 99). The [Setup] touch area on a screen in landscape orientation is the left quarter of the touch screen, and the [Calibration] touch area is the right quarter of the touch screen. If the terminal screen is in portrait orientation, the [Setup] touch area is the top quarter of the touch screen, and the [Calibration] touch area is the bottom quarter of the touch screen. This means that you can touch the upper left corner to access the Power On Setup utility and the lower right corner to perform calibration in either orientation.
Qlarity-Based Terminal Hardware
97
Page 110
Using a Touch Screen
Power On Setup
Figure 41 and Figure 42 identify the touch areas in each orientation.
Figure 41 Touch Screen Landscape Orientation
Figure 42 Touch Screen Portrait Orientation NOTE
☞
If your touch screen is not working properly, it may need calibration. Refer to section 8.5 for instructions. Do the following to start Power On Setup using a touch screen. 1. Turn off power to the terminal. 2. Press and hold the [Setup] touch area (see Figures 41 and 42) as you power on the terminal.
98
Qlarity-Based Terminal Hardware
Page 111
Power On Setup
Using a Touch Screen
3. Continue pressing until “Power On Setup” appears on the screen, then release the touch area. 4. If a password is required, the prompt, “Enter password,” is displayed. Press the arrow touch keys on the screen (↑ ↓ ← →) to enter the password, and then press [Select]. After the password is entered, Power On Setup starts. If you enter the password incorrectly, you must power the terminal off and back on and start over if you want to access all Power On Setup functions. If a password is required but not entered or entered incorrectly, Power On Setup starts and some limited functions are available including Display, Calibration, and Done. Use the touch keys described below to select functions and options in Power On Setup. To move from category to category: Press [Next] to move forward from one category of functions (e.g., Flash Memory, Display, Calibration, etc.) to another. A heading is highlighted when you move to it. Continue to press [Next] to move to the next page. Press [Back] to move backwards through the categories. To move within a category: When the heading of the category you want to edit is highlighted, press [Select] to move to the first function. Press [Next] and [Back] to move from function to function in the category. To go back to the category heading, go to the topmost function in the category and press [Back]; or go to the bottommost function and press [Next]. [Next] and [Back] then move from category to category again. To change a function: When at a function that you want to edit, press [Select] to move to the available options. Press [Next] or [Back] to toggle through the options (e.g., “off” and “on”). When the option you want is displayed, press [Select] to select the option and move back to the function name. To save and exit: When you are ready to exit Power On Setup, press either [Next] or [Back] (with a category heading highlighted) to move to DONE on the last page, and press [Select]. “Save and Exit” is highlighted. Press [Select] to save your changes and exit Power On Setup. To exit without saving the changes, press [Next] to move to Exit w/o Save and then press [Select]. NOTE
☞
Due to screen size limitations, the QTERM-G58 Power On Setup screen does not include touch keys for [Next], [Back] and [Select]. Instead, use the keypad as described in section 8.2. Refer to section 8.4 for information on specific functions.
Qlarity-Based Terminal Hardware
99
Page 112
Using a Keypad
Power On Setup
8.2 Using a Keypad You will use the left-most three keys on the top row of the keypad to navigate in Power On Setup. On the Beijer Electronics standard legends, these keys are labeled F1, F2 and F3. Key assignments are as follows. F1
[Back] move between categories, functions and options
F2
[Select] select a category, function or option
F3
[Next] move between categories, functions and options
Do the following to start Power On Setup using a keypad. 1. Turn off power to the terminal. You will need to remove power from the terminal or unplug it to turn off the power. 2. Press and hold any three keys (other than the Power key) as you power on the terminal. If the terminal is in Development Mode (see below), press and hold any single key (other than the Power key) as you apply power to the terminal 3. Continue to hold these keys until the words “Power On Setup” appear on the screen, then release the keys. 4. If a password is required, the prompt, “Enter password,” is displayed. Press the password key sequence on the keypad to enter the password, then press the [Select] key. After the password is entered, Power On Setup starts. If you enter the password incorrectly, you must power the terminal off and back on and start over if you want to access all Power On Setup functions. If a password is required but not entered or entered incorrectly, Power On Setup starts and some limited functions are available including Display, Calibration, and Done. Use the keypad keys described below to select functions and options in Power On Setup. To move from category to category: Press [F3] to move forward from one category of functions (e.g., Flash Memory, Display, Calibration, etc.) to another. A heading is highlighted when you move to it. Continue to press [F3] to move to the next page. Press [F1] to move backwards through the categories. To move within a category: When the category heading you want to edit is highlighted, press [F2] to move to the first function. Press [F1] and [F3] to move from function to function in the category. To go back to the category heading, go to the topmost function and press [F1]; or go to the bottommost function and press [F3]. [F1] and [F3] then move from category to category again.
100
Qlarity-Based Terminal Hardware
Page 113
Power On Setup
Using a Keyboard
To change a function: When at a function that you want to edit, press [F2] to move to the available options. Press [F1] and [F3] to toggle through the options (e.g., “off” and “on”). When the option you want is displayed, press [F2] to select the option and move back to the function name. Saving and Exiting: When you are ready to exit Power On Setup, press either [F1] or [F3] (with a category heading highlighted) to move to DONE on the last page, and press [F2]. “Save and Exit” is highlighted. Press [F2] to save your changes and exit Power On Setup. To exit without saving the changes, press [F3] to move to Exit w/o Save and press [F2]. Refer to section 8.4 for information on specific functions.
8.3 Using a Keyboard You will use the following keyboard keys in Power On Setup. <P> start Power On Setup
←→ move between categories, functions, and options
<Enter> select a category, function, or option
Do the following to start Power On Setup using a keyboard. 1. Turn off power to the terminal. 2. Press and hold the <P> key as you power on the terminal. 3. Continue to hold <P> until the words “Power On Setup” appear on the screen, then release the key. 4. If a password is required, the prompt, “Enter password,” is displayed. Press the arrow keys (↑ ↓ ← →) on the keyboard (not the number key pad) to enter the password, and then press <Enter>. After the password is entered, Power On Setup starts. If you enter the password incorrectly, you must power the terminal off and back on and start over if you want to access all Power On Setup functions. If a password is required but not entered or entered incorrectly, Power On Setup starts and some limited functions are available including Display, Calibration, and Done. Use the keyboard keys described below to select functions and options in Power On Setup. To move from category to category: Press → to move forward from one category of functions (e.g., Flash Memory, Display, Calibration, etc.) to another. A heading is highlighted when you move to it. Continue to press → to move to the next page. Press ← to move backwards through the categories.
Qlarity-Based Terminal Hardware
101
Page 114
Power On Setup Functions
Power On Setup
To move within a category: When the category heading you want to edit is highlighted, press <Enter> to move to the first function. Press → and ← to move from function to function in the category. To go back to the category heading, go to the topmost function and press ←; or go to the bottommost function and press →. → and ← then move from category to category again. To change a function: When at a function that you want to edit, press <Enter> to move to the available options. Press → and ← to toggle through the options (e.g., “off” and “on”). When the option you want is displayed, press <Enter> to select the option and move back to the function name. Saving and Exiting: When you are ready to exit Power On Setup, press either → or ← (with a category heading highlighted) to move to DONE on the last page, and press <Enter>. “Save and Exit” is highlighted. Press <Enter> to save your changes and exit Power On Setup. To exit without saving the changes, press → to move to Exit w/o Save and then press [Enter]. Refer to section 8.4 for information on specific functions.
8.4 Power On Setup Functions This section describes the functions in the Power On Setup utility by category. The categories are as follows:
• Flash Memory • Display • Calibration • Network (with optional Ethernet port only) • COM1 (and any additional installed serial ports) • Keypad (optional) • Keyboard (optional) • Sound • Feedback • Miscellaneous • Diagnostics (with keyboard/keypad only) • Done
102
Qlarity-Based Terminal Hardware
Page 115
Power On Setup
Power On Setup Functions
The following descriptions provide instructions for using the touch keys on a touch screen. If you are using a keyboard, the corresponding keyboard keys are as follows. Touch key
Keyboard key
Keypad key
[Select]
<Enter>
[F2]
[Back]
← →
[F1]
[Next]
[F3]
8.4.1 Flash Memory The Flash Memory functions are used to place the terminal in the proper mode to download new firmware or a user application, place the terminal in the proper mode for developing a new user application or normal operation, and erase the flash file system.
8.4.1.1 App Mode Download: Select this option to place a terminal with either a serial port or the optional Ethernet port in the mode to download new firmware or a new user application that you want saved in flash memory. (Use “App Mode: Develop” if you do not want to save the user application to flash memory.) The terminal waits for the download and detects the type of file (firmware or user application) as it is sent. NOTE
☞
If using an Ethernet port, make sure you have selected the proper network settings (see section 8.4.4). Press [Next] or [Back] to move to FLASH MEMORY. Press [Select] to move to App Mode, and press [Select] again to move to the options. Press [Next] or [Back] to select Download, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit. The terminal is ready to receive a download. Download the firmware or a user application using the “Download Application” or “Upgrade Firmware” function in Qlarity Foundry (refer to the Qlarity Foundry User's Manual for instructions). When the unit is reset, it will automatically go into the Run App mode. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup. Develop: Select this option to set the terminal to the “Develop” application mode, normally only used when you are developing a new user application and want to download it to the terminal without saving it in flash memory. Press [Next] or [Back] to move to FLASH MEMORY. Press [Select] and then [Next] to move to App Mode, and press [Select] again to move to the
Qlarity-Based Terminal Hardware
103
Page 116
Power On Setup Functions
Power On Setup options. Press [Next] or [Back] to select Develop, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit. The terminal is ready for the user application to be downloaded. Download the application through the serial or Ethernet port interface using the “Download Application” function in Qlarity Foundry (refer to the Qlarity Foundry User's Manual for instructions). (If you use an Ethernet port, make sure you have selected the proper network settings; see section 8.4.4.) While the terminal is in “Develop” mode, a user application downloaded to the terminal is not saved in flash memory. This saves unnecessary wear on the flash memory and speeds up download time while testing an application in development. However, the application is removed when the terminal is powered off. If you previously downloaded an application using the “App Mode: Download” function, that application remains in flash memory (it is not overwritten by an application downloaded while in develop mode). This makes it possible to test a new application without copying over an existing application. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup. Run App: Select this option to set the terminal to the “Run App” operational mode. If the terminal is in “Run App” mode and a user application was saved in flash memory, the application runs when the terminal is powered on. Press [Next] or [Back] to move to FLASH MEMORY. Press [Select] and then [Next] to move to App Mode, and press [Select] again to move to the options. Press [Next] or [Back] to select Run App, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup. Run Default: Select this option to set the terminal to the “Run Default” operational mode. If the terminal is in “Run Default” mode, the default application associated with the firmware runs when the terminal is powered on. Not all firmware builds have a default application. Press [Next] or [Back] to move to FLASH MEMORY. Press [Select] and then [Next] to move to App Mode, and press [Select] again to move to the options. Press [Next] or [Back] to select Run Default, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.
104
Qlarity-Based Terminal Hardware
Page 117
Power On Setup
Power On Setup Functions
8.4.1.2 Erase FFS Use this function to erase the flash file system. The flash file system is used to store data collected by the application. The data is saved to flash memory so that it is available even after the terminal has been powered off and back on. Press [Next] or [Back] to move to FLASH MEMORY. Press [Select] and then [Next] to move to Erase FFS, and press [Select] again to move to the options. Press [Next] or [Back] to select Yes. The flash file system is erased when you press [Select] to return to the function name. If you do not want to erase the flash file system, select No, and press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.
8.4.2 Display The Display functions are used to adjust the terminal display’s contrast setting, adjust the brightness of the display’s backlighting, change the orientation of the display (portrait or landscape), and use of draw caching.
8.4.2.1 Contrast Use this function to adjust the contrast setting of the terminal display. It will not appear on TFT units. Press [Next] or [Back] to move to DISPLAY. Press [Select] to move to Contrast, and press [Select] again to move to the options. The label, “(adjust)” is displayed on the right. Press [Next] or [Back] until the contrast is at the desired level. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup. NOTE
☞
The contrast can also be adjusted using an API function (see the Qlarity-based Terminal Programmer's Reference Manual.).
8.4.2.2 Backlight Use this function to adjust the brightness of the display. Press [Next] or [Back] to move to DISPLAY. Press [Select] and then [Next] to move to Backlight, and press [Select] again. The label, “(adjust)” is displayed on the right. Press [Next] or [Back] until the backlight is at the desired level. Press [Select] to return to the function name.
Qlarity-Based Terminal Hardware
105