Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 14

Qlarity-Based Terminal Hardware Manual: Power On Setup, pages 127 to 134

Pages 127 to 134 of 134, from Qlarity-Based Terminal Hardware Manual

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the QSI Corp QTERM-G55 and Beijer QTERM-G55

Page 127

Power On Setup

Power On Setup Functions

Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.8.6 AutoPower When AutoPower is enabled, the terminal will enter a low power sleep mode when the Power key on the keypad is pressed. If asleep, pressing the Power key awakens the terminal and resumes program execution. Set AutoPower to Off to disable this behavior. When AutoPower is disabled, pressing the Power key will generate normal key messages, and the Power LED may be manipulated using the SetLED API. Press [Next] to move to AutoPower, then press [Select] to move to the options. Press [Next] or [Back] to select On or Off. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.8.7 Keypad Backlight This section will only appear if your terminal includes a keypad backlight. Use this function to set the default state of the keypad backlight (at power on). Select On to turn the keypad backlight on when the power is applied to the unit, or select Off to turn the keypad backlight off when the power is applied. Press [Next] to move to BACKLIGHT in the KEYPAD section, then press [Select] to move to the options. Press [Next] or [Back] to select On or Off. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.9 Keyboard You will only see this category if you have a keyboard connected to the terminal. The Keyboard functions are used to set the key repeat delay time and rate.

8.4.9.1 Rpt Delay Use this function to select the delay time that you want between when a key is pressed and when it begins to repeat automatically. Press [Next] to move to Rpt Delay, and press [Select] to move to the options. Press [Next] or [Back] to select the key repeat delay time. The choices are: 250, 500, 750, or 1000 milliseconds. Press [Select] to return to the function name.

Qlarity-Based Terminal Hardware

115

Page 128

Power On Setup Functions

Power On Setup

Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.9.2 Rpt Rate Use this function to select the time that you want between each repeat when a key begins to repeat automatically. Press [Next] to move to Rpt Rate, and press [Select] to move to the options. Press [Next] or [Back] to select the key repeat rate. The choices range from 2.0 to 30.0 characters per second (cps). The default is 6 cps. Press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.10Sound This section only appears if the audio decoder option has been installed.

8.4.10.1Volume Set the master volume of the speaker. This affects volume of sounds played by the PlaySound API as well as that of the PlayNote API. (Exception: on QTERM-G55 terminals, only the PlayNote API is affected by the volume setting.) Press [Next] or [Back] to move to SOUND. Press [Select] and then press [Select] again to move to the Volume setting. Press [Next] or [Back] until the volume is at the desired level. A tone will be played with each press to indicate the current volume.

8.4.10.2Note Amplitude Set the volume of beeps played by calls to PlayNote on units that include the optional audio decoder. Press [Next] or [Back] to move to SOUND. Press [Select] and then press [Next] again to move to the Note Amp setting. Press [Select] again to start setting the note amplitude. Press [Next] or [Back] until the volume is at the desired level. A tone will be played with each press to indicate the current volume.

8.4.11Feedback The feedback functionality controls how the unit reports development information and fatal errors. Any combination of COM1, Display, USB, and UDP ( Ethernet, if available) can be selected.

116

Qlarity-Based Terminal Hardware

Page 129

Power On Setup

Power On Setup Functions

8.4.11.1Serial Use this function to enable or disable feedback to the primary serial (COM1) interface. Press [Select] and [Next] to move to Serial, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.11.2Video Use this function to enable or disable feedback to the display. Press [Select] and [Next] to move to Video, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.11.3USB Use this function to enable or disable feedback to the USB device communications interface. Press [Select] and [Next] to move to USB, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. NOTE

☞

Feedback via the USB device communications interface requires installation of the Beijer Electronics USB Communications drivers and a PC host application to gather and display the feedback. Contact Beijer Electronics Technical Support for additional details. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.11.4UDP Use this function to enable or disable feedback to the network interface via the UDP protocol. If this option is enabled, you should also set the desired IP address and port number to receive the feedback (see Addr and Port Number below). Press [Select] and [Next] to move to UDP, and press [Select] again to move to the options. Press [Next] or [Back] to select On or Off, then press [Select] to return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

Qlarity-Based Terminal Hardware

117

Page 130

Power On Setup Functions

Power On Setup

8.4.11.5Addr Use this function to set the IP address to send UDP packets to for feedback. Press [Next] or [Back] to move to FEEDBACK. Press [Select] and [Next] to move to the “UDP” field. Press [Select] again to move to the first digit in the “UDP” field. Press [Next] or [Back] to change the digit's value. Press [Select] to move to the next digit and press [Next] or [Back] to change it. Continue to press [Select] and change each digit in the address as required. Press [Select] at the last digit to return to the UDP field. NOTE

☞

If you are using a keyboard, you can use the number keys (0-9) to enter the digits. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.11.6Port Number Use this function to set the port number to send UDP feedback packets to. Press [Next] or [Back] to move to FEEDBACK. Press [Select] and [Next] to move to the “Port” field. Press [Select] again to move to the first digit in the “Port” field. Press [Next] or [Back] to change the digit's value. Press [Select] to move to the next digit and press [Next] or [Back] to change it. Continue to press [Select] and change each digit in the Port number as required. Press [Select] at the last digit to return to the Port field. NOTE

☞

If you are using a keyboard, you can use the number keys (0-9) to enter the digits. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.12Miscellaneous The Miscellaneous functions include the setting up of a password for Power On Setup and also a unit information display screen.

8.4.12.1Information Use this function to determine the current version of firmware, current BFF version, minimum BFF version, amount of RAM, amount of flash memory, the current flash file system size, and Ethernet MAC address of the unit. Press [Next] or [Back] to move to MISCELLANEOUS. Press [Select] to move to Information, and press [Select] again to view this data.

118

Qlarity-Based Terminal Hardware

Page 131

Power On Setup

Power On Setup Functions

Press any key to exit this screen and return to the function name. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.12.2Use Password Use this function to determine whether or not a password is required to access the Power On Setup utility. Press [Next] or [Back] to move to MISCELLANEOUS. Press [Select] to move to Use Password, and press [Select] again to move to the options. Press [Next] or [Back] to select Yes or No, then press [Select] to return to the function name. If you selected Yes, the “Change Password” function appears for you to define the password, as described in the following section. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.12.3Change Password You will only see this function if you selected Yes at the “Use Password” field. Use this function to set up or change the Power On Setup password (see section 8.4.12.2). Press [Next] to move to Change Password, and press [Select]. The “Enter Password” prompt and the arrow keys (↑ ↓ ← →) with the [Select] key in the center are displayed. Press a series of arrow keys in the order they must be entered as the password (e.g., ↑↑→→). An asterisk (*) appears in the “Enter Password” prompt for each arrow you press. When you have finished entering the password, press [Select] (in the center of the display). The “Confirm New Password” box is displayed. Enter the password a second time to confirm it. The message, “Password will be changed on exit with save” is displayed. Press [Next] or [Back] to move to the DONE section, and select Save and Exit to exit Power On Setup. The next time you access Power On Setup, the new password will be required.

8.4.13Diagnostics You will only see this category if your terminal is set up to use a keypad or keyboard. Use the Diagnostics functions to verify that a keypad or keyboard key is working properly. NOTE

☞

Because the <Enter> key is required to exit Diagnostics, you cannot test it. All other keys may be tested.

Qlarity-Based Terminal Hardware

119

Page 132

Power On Setup Functions

Power On Setup

8.4.13.1Keypad Key Use this function to verify that keypad keys are mapped correctly on the terminal. Press → or ← to move to DIAGNOSTICS. Press <Enter> to move to Keypad Key, and press <Enter> again. Press the key on the keypad that you want to test. The location (row and column) of the key that you pressed is displayed so that you can verify that it is correct. Press each key that you want to test. Press <Enter> to end diagnostics. Press → or ← to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.13.2Keybrd Key You will only see this function if you have a keyboard connected to your terminal. Use this function to verify that keyboard keys are mapped correctly on the terminal. Press → or ← to move to DIAGNOSTICS. Press <Enter> to move to Keybrd Key, and press <Enter> again. Press the key on the keyboard that you want to test. The character that is mapped to the key you pressed is displayed, along with the decimal scan code in parenthesis. Press each key that you want to test. To test mapping of key combinations, press <Shift>, <Ctrl>, or <Alt> (as applicable) with the appropriate key. Press <Enter> to end diagnostics and return to the function name. Press → or ← to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.13.3Transmit Key Use this function to send the results of the “Keypad or Keyboard Key” test through the COM1 port. Press → or ← to move to DIAGNOSTICS. Press <Enter> and then → to move to Transmit Key, and press <Enter> to move to the options. Press → or ← to select Yes or No, then press <Enter> to return to the function name. Press → or ← to move to the DONE section, and select Save and Exit to exit Power On Setup.

8.4.13.4SDRAM Test Some Qlarity-based terminals include the ability to do a comprehensive, non-destructive test on the synchronous DRAM memory. The contents of memory and the processor state are unharmed by the test.

120

Qlarity-Based Terminal Hardware

Page 133

Power On Setup

Touch Screen Calibration

Press [Next] to move to SDRAM TEST. Press [Select] to execute the test. A small dialog will appear indicating that the test is in process. When the test is completed (typically a few seconds) the dialog will change to indicate success or failure. Contact the Service Department at Beijer Electronics if you terminal reports a failure.

8.4.14Done Use the Done functions to exit Power On Setup with or without saving your changes.

8.4.14.1Save and Exit Press [Next] or [Back] to move to DONE. Press [Select] to move to Save and Exit, and press [Select] again to save your changes and exit Power On Setup. All changes that were made while in the Power On Setup utility are saved and reflected the next time the terminal is powered on. NOTE

☞

Changes performed to the settings for “Erase FFS,” “Time,” and “Date” take effect immediately.

8.4.14.2Exit w/o Save Press [Next] or [Back] to move to DONE. Press [Select] and then [Next] to move to Exit w/o Save, and press [Select] again [Select] to exit Power On Setup without saving the changes.

8.5 Touch Screen Calibration If the touch screen is not working properly (e.g., if the touch keys do not work), it probably needs calibration. If you cannot navigate with the touch keys in the Power On Setup utility, do the following to switch the terminal to calibration mode and calibrate the touch screen without entering Power On Setup. 1. Turn off power to the terminal. 2. Press and hold the [Calibrate] touch area (see the illustrations in section 8.1, “Using a Touch Screen” for touch area locations) as you power on the terminal. 3. Continue pressing until the message, “TOUCHSCREEN CALIBRATION, Please press center of cross” is displayed and a “+” symbol appears on the screen. 4. Press the “+” symbol. The symbol moves to the bottom of the display. 5. Press the “+” symbol in its new location to complete calibration. NOTE

☞

You can also calibrate the touch screen using the “Touchscreen” function in Power On Setup (see section 8.4.3.4).

Qlarity-Based Terminal Hardware

121

Page 134

Touch Screen Calibration

Power On Setup

Notes

122

Qlarity-Based Terminal Hardware