M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ Port Select Code is:$BT Enter Port Select Code (Max. 8 Characters) and ENTER when done:
Type the desired port select code followed by <cr>. For example, if you type #PORT followed by <cr>, the V71 will respond with: Port Select Code is:#PORT Enter Port Select Code (Max. 8 Characters) and ENTER when done:
If no additional change is desired, type <cr>. The V71 saves the new port select code permanently in the non-volatile memory and return to the main configuration menu. NOTE: You cannot program the port select code to be $BAYTECH from the service port. If you wish to use $BAYTECH as the port select code, you must program the port select code from the V71 host module. SERIAL PORT CONFIGURATION Type “3” and <cr> to enter the serial port menu. The V71 will respond: Port
Baud Rate
1 9600 Exit/Save Set Baud Rate Set Word Size
Word Size
Stop Bits
8
1 1 2 3
Parity
Xon / Xoff Xmit Recv None Off Off Set Stop Bits 4 Set Parity 5 Set XON/XOFF 6
Line Interface EIA-232 Set Line Interface
7
Enter Request :
You can now reconfigure the V71 by selecting the appropriate option from the menu (1 to 7). For example, to change the baud rate to 115.2K baud, send "2" (Set baud rate). The V71 will respond with this menu: 1 for 50 2 for 75 3 for 110 4 for 135 5 for 150 6 for 300 7 for 600 8 for 1200 9 for 2400 A for 4800 B for 9600 C for 19200
49
Page 62
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ D for 38400 E for 57600 F for 76800 G for 115.2K Enter Request :
Send "G" for 115.2K baud rate, and the V71 will respond with the reconfigured status of the port, the option menu, and the prompt: Port
Baud Rate
Word Size
Stop Bits
Parity
1
115200
8
1
None
Exit/Save Set Baud Rate Set Word Size
1 2 3
Xon / Xoff Xmit Recv Off Off
Set Stop Bits Set Parity Set XON/XOFF
4 5 6
Line Interface EIA-232 Set Line Interface
7
Enter Request :
You can now select other options from the menu. For example, to change the line interface to EIA-422, type "7" (Set Line Interface) and the V71 will respond with: 1 for EIA-232 2 for EIA-422 3 for 20mA Current Loop Enter Request :
Type "2" for EIA-422 line interface and the V71 will respond with the reconfigured status of the port, the option menu, and the prompt: Port
Baud Rate 1 115200 Exit/Save Set Baud Rate Set Word Size
Word Size 8 1 2 3
Stop Parity Xon / Xoff Bits Xmit Recv 1 None Off Off Set Stop Bits 4 Set Parity 5 Set XON/XOFF 6
Line Interface EIA-422 Set Line Interface
7
Enter Request :
If there are no other changes, send "1" (Exit/Save) and the V71 will return to the main configuration menu. NOTE: The new serial port configuration changes do not take effect until after you exit configuration mode.
50
Page 63
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
EXIT CONFIGURATION Type “X” and <cr> to exit the configuration menu. The V71 will respond: Change your devices to match new configuration
This reminds you to change the host computer to match any serial port configuration changes. You should change the appropriate host computer parameters to match the new serial port configuration of the V71 at this point. CAUTION: Failure to change the host computer serial parameters to match the new serial parameters of the V71 after exiting configuration mode locks you out of all V71 functions. If this happens and you forget what changes were made, you can review the V71 configuration status and make any changes from the service port or the service modem of the M Series base unit. IMPORTANT: After exiting the V71 configuration mode and making any necessary changes to the host computer, you must send the port select code immediately followed by <cr> (e.g., $BT<cr>) to resume normal communications between the V71 and the relevant I/O modules. Failure to do so prevents the V71 from receiving any data from the I/O modules.
V72TP HOST MODULE CONFIGURATION MAIN CONFIGURATION MENU Configuration changes for the V72/V72TP host modules are made through the service port, or the service modem. To access the configuration mode of of the V72/V72TP module use the procedures on page 45. With $CONFIG input the V72/V72TP host module installed as Module X will respond with an identification block and a menu of the available configuration options similar to the following: M-Series V72-TP DAC Host Unit : 1 Module: 1 F 0.28 Copyright (c) 1995-1997
51
Page 64
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ Bay Technical Associates IP Addr: Gateway Addr: Ethernet Addr: Unit Mem (MB): TCP Sessions: BrkLen
200.4.3.190 200.4.3.1 00.C0.48.1A.24.5D 16 0 350 ms
IP Address Subnet Mask Gateway Select Code Password User Interface Diagnostics Exit
1 2 3 4 5 6 7 X
Subnet Mask: Select Code: ID MSG/Login: IMR/CRT: Menu/ATTN: Hst Cfg/RTel
255.255.255.0 $BT enabled/enabled disabled/disabled disabled disabled/enabled
NOTE: The Unit Mem (MB) line, showing the amount of memory is displayed only if an M03 memory module is installed. You can now make whatever changes are necessary by responding to the above menu. The "X" selection (Exit Configuration) will return you to the operations mode. IP ADDRESS Type “1” (in the configuration main menu) and <cr> to change the IP address. The module will respond: Enter IP address in dotted decimal form:
Enter the desired IP address as a series of four numbers separated by periods (e.g., 197.3.14.9) followed by <cr>. IMPORTANT: The IP address must be programmed before the V72 module can be accessed on the network. After programming the IP address, the MSeries unit must be reset for the new information to take effect. SUBNET MASK Type “2” (in the configuration main menu) and <cr> to change the subnet mask. The module will respond: Enter Subnet Mask in dotted decimal form:
Enter the desired Subnet Mask as a series of four numbers separated by periods (e.g., 255.255.255.0) followed by <cr>. IMPORTANT: The Subnet Mask must be programmed before the V72 module can be accessed on the network. After programming the Subnet Mask, the M-Series unit must be reset for the new information to take effect. GATEWAY
52
Page 65
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
Type “3” (in the configuration main menu) and <cr> to change gateway. The module will respond: Enter Gateway address in dotted decimal form:
Enter the desired Gateway or router address as a series of four numbers separated by periods (e.g., 197.3.14.1) followed by <cr>. IMPORTANT: After programming the Gateway address, the M-Series unit must be reset for the new information to take effect. SELECT CODE Type “4” (in the configuration main menu) and <cr> to change the select code. The module will respond: Enter Select Code (8 chars max):
Type the desired port select code followed by <cr>. The V72 saves the new port select code permanently in the non-volatile memory and returns to the main configuration menu. NOTE: The select code is case sensitive. You cannot program the port select code to be $BT from the service port or service modem. NOTE: It is not necessary to reset the unit for this option to take effect. PASSWORD Type “5” (in the configuration main menu) and <cr> to change the password. The module will respond: Current password: BTA Enter Password (8 chars max):
Type the desired password up to eight ASCII characters. Press <cr> to return to the main configuration menu. IMPORTANT: Record your password and keep it in a secure place. If a password is lost or forgotten, you must contact a BayTech applications engineer and provide authenticated authorization for the password retrieval procedure. NOTE: The password is case sensitive. Any non-alphanumeric character including <BACKSPACE> and <DELETE> or a password greater than eight characters is interpreted as an input error and you will be prompted to enter the password again. Terminate the password entry by typing the <cr> key. The V72 will respond with:
53
Page 66
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ Accept password as typed above? (Y/N) :
Press "Y" to accept the new password or "N" to reject it. If you press "N", the V72 will return to the "Enter Password" prompt. If you type "Y", the V72 will return to the main configuration menu. NOTE: It is not necessary to reset the unit for this option to take effect. USER INTERFACE Type “6” (in the configuration main menu) and <cr> to move through the following options: User interface options, press <CR> to skip option . Enable/Disable Module ID Message? (E/D):
Press “E” to enable the Module ID Message, press “D” to disable the ID Message or press <cr> to leave the option unchanged. The default is “enabled”. Enable/Disable Login? (E/D):
Press "E" to enable the Login Procedure, press "D" to disable the Login Password Procedure or press <cr> to leave this option unchanged. The default is “enabled NOTE: It is not necessary to reset the unit for this option to take effect. Enable/Disable Immediate Msg Quick Release? (E/D):
Press "E" to enable the Immediate Mode Message Quick Release Procedure, press "D" to disable this procedure, returning the module to normal message handling mode or press <cr> to leave this option unchanged. The default is “disabled”. Enable/Disable strip LF/NUL after CR? (E/D):
Press "E" to make the V72’s Telnet processor to strip line feeds or nulls which follow carriage returns, press “D” to allow the characters to pass through or press <cr> to leave this option unchanged. The default is “disabled”. Enable menu interface? (E/D):
Press “E” to enable the Menu interface mode of operation for the V72, press “D” to disable the Menu interface mode of operation for the V72, or press <cr> to leave this option unchanged The default is “enabled”. If the menu is enabled the following prompt appears: Enter menu attention Character:
54
Page 67
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
Enter the attention character desired. The default is a semi-colon (;). In the menu mode of operation, the attention character is typed five times with no characters in between. This returns the user to the host module main menu. Enable/Disable configuration from other hosts? (E/D):
Users may configure a V72/V72TP to allow it to be configured through other host modules, rather than just through the serial port. The default setting for “Hst Cfg” (Host Configuration) is disabled. Enable/Disable reverse telnet feature (E/D):
When users want to prevent V71, V93A, or service port users from gaining access to the network through the V72/V72TP, the reverse Telnet feature may be disabled. The default setting for “Rtel” (Reverse Telnet Operation) is enabled. Set Break Length? (Y/N):
Users may configure the V72/V72TP for a break length of 25 - 6.375 milliseconds (.025 - 6.375 seconds) in 25 millisecond increments. When a user, running a Telnet session with the V72/V72TP and connected to a serial port on a V74/V75, sends a Telnet break command (0xF4) to the V72/V72TP, the serial port will send a break signal of the programmed duration. The default setting for the Programmable Break on the V72/V72TP is 350 milliseconds. If you answer yes you will be prompted for the break length: Enter Break Length (25 ms ticks), <CR>:
DIAGNOSTICS Type “7” (in the configuration main menu) and <cr> to display status and diagnostics menu. The module will respond: V72 Status & Diagnostics Menu. System Internal Communications Network Interface Logged Users Exit
1 2 3 4 X
SYSTEM STATUS Type “1” (in the status and diagnostics menu) and <cr> to display the system status. The module will respond: System Status: Available local memory (256 byte buffers): 511 System memory (M03 modules, MB): 0
55
Page 68
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________ Connections in use: 0 Pending messages (module #s): none Immediate Mode User: none Command/Configuration Mode User: Module 0 System up time (days:hh:mm:ss): 0:02:05:29 <Strike any key to continue.>
INTERNAL BUS STATUS Type “2” (in the status and diagnostics menu) and <cr> to display the internal bus status. The module will respond: Internal Bus Status: Internal Bus Errors: 0 Bus transmit data channel: clear <Strike any key to continue.>
NETWORK STATUS Type “3” (in the status and diagnostics menu) and <cr> to display the network status. The module will respond: Network Status: Medium status: good Medium faults: 0 Xmit bufr errs: 0 Available send buffers: 30 Receive queue status: open <Strike any key to continue.>
LOGGED USERS Type “4” (in the status and diagnostics menu) and <cr> to display the active users. The module will respond: Active Users: Address/Port Internal TX/RX TX/RX Module 0 C 0,1/0,1
Net Data Flo TX/RX
<Strike "T" to terminate a session, any other key to continue.>
56
Bus Data Flo ok/ok
Page 69
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
EXIT Type “X” (in the status and diagnostics menu) and <cr> exit the configuration menu. The module will respond: Unit MUST BE RESET for configuration changes to take effect.
V74/V75/V87 SERIAL I/O MODULE CONFIGURATION Configuration changes for the V74/V75/V87 modules are made through any host module, the service port, or the front panel. To access the configuration mode of a 4port serial module from any host module, use the procedures on page 44. MAIN MENU CONFIGURATION With $CONFIG input the serial module installed as Module X will respond with an identification block and a menu of the available configuration options similar to the following: Copyright(C) Bay Technical Associates 199X-199X Model V73/V74/V76 etc. High Speed Serial 4C Revision F.X.XX Unit: 1, Module: 2 Status Serial Port Configuration Port Device Name Port I.D Designate Host Port location Message Terminate Character Mode of Operation Time Tag Mode Connect Port ID Echo Exit
1 2 3 4 5 6 7 8 9 X
Enter Request :
NOTE: Menu selection is case sensitive. It is recommended that your keyboard be in the CAPS LOCK position. IMPORTANT: If you change the Message Terminate Character or Mode of Operation, when you type "X" from the above menu (Exit), the module will respond with: Mode Of Operation or Terminate Character has been Changed! Press Any Key To Reset This Unit...
57
Page 70
M SERIES DAC BASE UNIT AND MODULE CONFIGURATION ____________________________________________________________________________
Typing any key results in the M Series base unit and all installed modules resetting. STATUS Type “1” (in the configuration main menu) and <cr> to display the module status. The module will respond: Current Terminate Character is 0DH Current Host Designation is Module Current Mode of Operation is
1 1
Strike any Key to Continue, or X to Exit Current Module 2 Serial Port Configuration :
Device Name Device A Device B Device C Device D
Baud Rate 9600 9600 9600 9600
Word Size 8 8 8 8
Stop Bits 1 1 1 1
Parity None None None None
Strike any Key to Continue, or X to Exit Current Module 2 Port I.D : Port Port I 1 01:02,1 2 01:02,2 3 01:02,3 4 01:02,4 Strike any Key to Continue, or X to Exit Copyright(C) Bay Technical Associates 199X-199X Model V73/V74/V76 etc. High Speed Serial 4C Revision F. X.XX Unit: 1, Module: 2 Status Serial Port Configuration Port Device Name Port I.D Designate Host Port location Message Terminate Character Mode of Operation
58
1 2 3 4 5 6 7
Xon/ Xoff Xmit Recv Off Off Off Off Off Off Off Off