Page 41

M SERIES DAC CABLING ____________________________________________________________________________

Once the V78 CRM-1 has been installed in the M Series chassis, connect a cable with a DB-25 male connector to the input connector, J2. The wiper (common), normally open (NO), and normally closed (NC) contacts of each relay are provided on a specific pin. Connect your control circuitry to the desired relay contacts as shown below. Circuit Connection

Pin #

Circuit Connection

Relay #1 Wiper Relay #1 NC Relay #1 NO

1 2 3

14 15 16

Relay #5 Wiper Relay #5 NC Relay #5 NO

Relay#2 Wiper

4

17

Relay #6 Wiper

Relay #2 NC

5

18

Relay #6 NC

Relay #2 NO

6

19

Relay #6 NO

Relay #3 Wiper

7

20

Relay #7 Wiper

Relay #3 NC

8

21

Relay #7 NC

Relay #3 NO

9

22

Relay #7 NO

Relay #4 Wiper

10

23

Relay #8 Wiper

Relay #4 NC Relay #5 NO No Connection

11 12 13

24 25

Relay #8 NC Relay #8 NO

Relay Contact Connection

V79/V80 Pinout The V79 PDI-1 and V80 PDI-2 are installed in the M Series chassis as described in the installation section of this manual. NOTE: The V79 PDI-1 or V80 PDI-2 cannot be installed as Module 1. If a V79 PDI-1 or V80 PDI-2 is removed from a module slot and a different V79 PDI-1 or V80 PDI-2 is installed in that location, the newly installed module acquires the previous module's configuration. Moving an V79 PDI-1 or V80 PDI-2 to a different module location requires reconfiguration because the

29

Page 42

M SERIES DAC CABLING ____________________________________________________________________________ configuration parameters are stored as a function of slot location and module type. The configuration information does not stay with a relocated module. The V79 PDI-1 and V80 PDI-2 modules each have a DC-37F connector. Equipment connections for each module is similar. Each input of the V79 PDI-1 module has a ground connection and each input of the V80 PDI-2 module has a return connection. The figures below show the V79 PDI-1 and V80 PDI-2 connections respectively. Circuit

Pin # Circuit Connection Connection

Circuit

Circuit

Connection

Connection

Input #1

Ground #10

Input #1

1

20

Input #11

Return #1

2

21

Ground #11

Input #2

3

22

Input #12

Return #2

4

23

Ground #12

Input #3

5

24

Input #13

Return #3

6

25

Ground #13

Input #4

7

26

Input #14

Return #4

8

27

Ground #14

Input #5

9

28

Input #15

Return #5

10 29

Ground #15

Input #6

11 30

Input #16

Return #6

12 31

Ground #16

Input #7

13 32

N.C.

Return #7

14 33

N.C.

Input #8

15 34

N.C.

Return #8

16 35

N.C.

Input #9

17 36

1 20 Return #10 Ground #1 2 21 Input #11 Input #2 3 22 Return #11 Ground #2 4 23 Input #12 Input #3 5 24 Return #12 Ground #3 6 25 Input #13 Input #4 7 26 Return #13 Ground #4 8 27 Input #14 Input #5 9 28 Return #14 Ground #5 10 29 Input #15 Input #6 11 30 Return #15 Ground #6 12 31 Input #16 Input #7 13 32 Return #16 Ground #7 14 33 N.C. Input #8 15 34 N.C. Ground #8 16 35 N.C. Input #9 17 36 N.C.

30

Pin #

Page 43

M SERIES DAC CABLING ____________________________________________________________________________ Ground #9 N.C. Input #10

18 37

N.C.

19

V79 Input Connections

0.2

Return #9

18 37

Input #10

19

V80 Input Connections

PDI-2 AC INPUT SETUP

The PDI-2 module has two banks of dip switches which are used to add ripple filtering for AC inputs. AC input is selected by individual channel. Location of the dip switches is shown in Figure 3.

CHANNEL

SW1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8

Table 1

SW2

1 2 3 4 5 6 7 8

Figure 3

Dip switch SW1 1-8 provides filtering control for channels 1-8 while SW2 1-8 controls channels 9-16. Refer to Table 1 to determine which switch corresponds to a particular channel. A port is configured for AC operation by positioning the corresponding switch to ON position. NOTE:

The default setting for SW 1-8 and SW2 1-8 is "OFF" (AC filtering disabled).

31

Page 44

M SERIES DAC CABLING ____________________________________________________________________________

V83 ECM-1 CABLING The ECM-1 is installed in the M Series chassis as described in Section 3.5 of the base unit operator's manual. NOTE: The ECM-1 cannot be installed as Module 1. If an ECM-1 is removed from a module slot and a different ECM-1 is installed in that location, the newly installed module acquires the previous module's configuration. Moving an ECM-1 to a different module location requires reconfiguration because the configuration parameters are stored as a function of slot location and module type. The configuration information does not stay with a relocated module. The ECM-1 module has a DC-37F connector. The DC-37F connector provides a means for individual connections to each input/out circuit as shown in Figure 1. Each input/output has a paired ground (return) connection. If all the input/output circuits are generated from a common source, a single-point ground can be used. Any of the ground connections can be used to provide the single-point ground.

Figure 1: ECM-1 Signal Connections

32

Circuit Connection

Pin #

Circuit Connection

Input #1 Ground #1 Input # 2

1 2 3

20 21 22

Ground # 10 Input # 11 Ground # 11

Ground # 2

4

23

Input # 12

Input # 3

5

24

Ground # 12

Ground # 3

6

25

Input # 13

Input # 4

7

26

Ground # 13

Ground # 4

8

27

Input # 14

Input # 5

9

28

Ground # 15

Ground # 5

10

29

Input # 16

Input # 6 Ground # 6 Input # 7 Ground # 7

11 12 13 14

30 31 32 33

Ground # 16 NC NC NC

Page 45

M SERIES DAC CABLING ____________________________________________________________________________ Input # 8 Ground # 8 Input # 9 Ground # 9 Input # 10

15 16 17 18 19

34 35 36 37

NC NC NC NC

Relay Contact Connection

NOTE: Ground loops are one of the most common problems encountered when connecting electronics equipment that are physically separated. To prevent noise or erroneous data being introduced, insure your signal connections do not form ground loops. Each counter circuit can be externally controlled through its corresponding "Gate/Out" connection. To operate a counter circuit as an externally controlled counter, set that counter's Gate/Out jumper to the GATE position, as shown in Figure 2. With the jumper in place, the counter input can be controlled by placing a "LO" at the GATE connection. When a counter circuit is to be used as a programmable divider, place the Gate/Out jumper to the "Out" position. Connect a reference signal to the corresponding Counter Input and set the divisor value as explained in Section 5.1.3. The divided output signal is provided at the corresponding Gate/Out connection.

33

Page 46

M SERIES DAC CABLING ____________________________________________________________________________

Figure 2: ECM-1 Board and GATE/OUT Jumpers V84 ADR-1/1A CABLING The ADR-1 and ADR-1A are installed in the M Series chassis as described in Section 4.5 of the base unit operator's manual. NOTE: The ADR-1 and ADR-1A cannot be installed as Module 1. Also, if an ADR-1(A) is removed from a module slot and a different ADR-1(A) is installed in that location, the newly installed module acquires the previous module's configuration. Moving an ADR-1(A) to a different module location requires reconfiguration because the configuration parameters are stored as a function of slot location and module type. The configuration information does not stay with a relocated module.

34

Page 47

M SERIES DAC CABLING ____________________________________________________________________________

Once the ADR-1 or ADR-1A has been installed in the M Series chassis, connect your analog and isolated voltage input signals to the input connector J1 with a HDL-44 male connector. Connect single-ended A-to-D ground returns to the minus (-) HDL44 pin connector for the channel(s) to be used. For example, if Channel 1 is used in single-ended mode, connect your signal under measurement to Pin 1 and the ground to Pin 2. Make all relay connections to the input connector J2 with a DA-15F connector. Configure your input cable as shown in Figure 1 on the following page for the ADR-1 analog and switch closure inputs, Figure 2 on Page 6 for the ADR-1A analog and isolated voltage inputs, or as shown in Figure 3 on Page 7 for relay connections. J1 Circuit Connection

No Connection A/D Channel #1+ No Connection A/D Channel #1Ground A/D Channel #2+ Ground A/D Channel #2Ground A/D Channel #3+ Ground A/D Channel #3Ground A/D Channel #4+ Ground A/D Channel #4Ground A/D Channel #5+ Ground A/D Channel #5Ground A/D Channel #6+ Ground A/D Channel #6Ground No Connection Ground No Connection Switch Input #1 Ground

Circuit Connection

Pin #

16 1

31

Ground

32

Switch Input #2

33

Ground

34

Switch Input #3

35

Ground

36

Switch Input #4

37

Ground

38

Switch Input #5

39

Ground

40

Switch Input #6

41

No Connection

42

No Connection

43

No Connection

44

No Connection

17 2 18 3 19 4 20 5 21 6 22 7 23 8 24 9 25 10 26 11 27 12 28 13 29 14 30 16

35

Page 48

M SERIES DAC CABLING ____________________________________________________________________________

Figure 1: ADR-1 Analog and Switch Closure Input Connections (HDL-44F)

36

Page 49

M SERIES DAC CABLING ____________________________________________________________________________ J1 Circuit Connection

A/D Channel 8+ A/D Channel #1+ A/D Channel 8A/D Channel #1Ground A/D Channel #2+ Ground A/D Channel #2Ground A/D Channel #3+ Ground A/D Channel #3Ground A/D Channel #4+ Ground A/D Channel #4Ground A/D Channel #5+ Ground A/D Channel #5Ground A/D Channel #6+ Ground A/D Channel #6Ground No Connection Isolated Input # 1+ No Connection Isolated Input # 1Ground

Circuit Connection

Pin #

16 1

31

Isolated Input # 2+

32

Isolated Input # 2-

33

Isolated Input # 3+

34

Isolated Input # 3-

35

Isolated Input # 4+

36

Isolated Input # 4-

37

Isolated Input # 5+

38

Isolated Input # 5-

39

Isolated Input # 6+

40

Isolated Input # 6-

41

No Connection

42

No Connection

43

No Connection

44

No Connection

17 2 18 3 19 4 20 5 21 6 22 7 23 8 24 9 25 10 26 11 27 12 28 13 29 14 30 16

Figure 2: ADR-1A Analog and Isolated Voltage Input Connections (HDL-44F) J2 Circuit Connection

Pin #

No Connection

8

No Connection

7

Circuit Connection

15

No Connection

14

Relay #4 NC

37

Page 50

M SERIES DAC CABLING ____________________________________________________________________________ Relay #2 NC

6

Relay #2 Wiper

5

Relay #2 NO

4

Relay #1 NC

3

Relay #1 Wiper

2

Relay #1 NO

1

13

Relay #4 Wiper

12

Relay #4 NO

11

Relay #3 NC

10

Relay #3 Wiper

9

Relay #3 NO

Figure 3: Relay Connections (DA-15M)

V93A The V93A modem has two modular connectors for device selection and configuration. One connector is for connection to a dial-up line. The other connector is used to communicate with an EIA-232 port. EIA-232 CONNECTION Connect the eight pin modular cable(RJ-45) to the port labeled EIA-232 on the V93A. Connect the DB9 adapter to the serial port of your PC or terminal and then connect the other end of the cable to the RJ-45 side of the adapter. Use adapter BayTech part number 9FRJ45PC-3 and cable, BayTech part number RJ08X007 that come with the RPC. Figure 1 shows the required adapter for a PC with a DB-25 connector. Use a crossed RJ-45 cable to connect these adapters to the EIA-232 port.

1

BLUE

2

ORANGE

3

BLACK

4

RED

5

GREEN

1

RJ-45

38

6

YELLOW

7

BROWN

8

GRAY

DCD

2

RX

3

TX

4

DTR

5

GND

6

DSR

7

RTS

8

CTS