Page 31
M SERIES DAC CABLING ____________________________________________________________________________
C. DCD "IN" or low which is necessary when a V74 or V75 port is connected to a modem. See figures 29 & 30 for jumper location.
PORT #
JP POSITIONS
PORT #1
11 GROUND 12 IN
PORT #2
9 GROUND 10 IN
PORT #3
7 GROUND 8 IN
PORT #4
5 GROUND 6 IN
USE ADAPTER: 25FRJ45MD-4 Refer to the line drawings below for DCD "IN", DCD "OUT" or "GROUND" selections and also for EIA-422 or EIA-232 selection. V75 JUMPERS are given on the drawing below. The RJ-45 connectors face toward the bottom of the page. Insert v75 jumper drawing
V74 JUMPERS are given on the drawing below. The RJ-45 connectors face toward the bottom of the page. Insert v74 jumper drawing
14.1.3
V75 SERIAL INTERFACE SELECTION
The desired V75 serial interface is selected by positioning jumpers on the main board of the module for each individual port. The factory default serial interface is EIA422.
19
Page 32
M SERIES DAC CABLING ____________________________________________________________________________
Refer to Figure 29 on previous page and locate the eight jumper locations for serial interface selection. These jumper locations are marked on the mechanical layout as JP13 and JP14 for Port 1, JP15 and JP16 for port 2, JP17 and JP18 for Port 3 and JP19 and JP20 for Port 4. Each port is configurable for EIA-422 or EIA-232 serial interface by installing two, 4 position jumpers to either the 422 or 232 position as marked on the board. The center row of pins for each port will be occupied by four of the jumper positions and the row of pins for either 422 or 232 will be occupied by the other four positions of these two jumpers. IMPORTANT: If the V75 module is installed in the base unit chassis, remove power from the unit by positioning the On/Off switch to "O" (off) and unplug the power cord from the AC outlet. Remove the module by unscrewing the two screws securing it to the back panel and pull the module out. 14.1.4
V74 AND V75 CABLE/ADAPTER INFORMATION
Refer to the following modular adapter drawings to interface your computers or terminals to the V74 and the V75 module using EIA-232 serial interface. Use the "...PC-1" adapters in most data acquisition and control applications where the V74 or V75 will not have modem connections. Refer to Figure 31 if your computers/terminals have DB-25 male connectors or to Figure 32 if your computers/terminals have DE-9 connectors.
Insert drawings for the 25 pin and 9 pin pc1 adapter
Refer to the following modular adapter drawings to interface your computers or terminals to the V74 or V75 module using EIA-232 serial interface. Use the "...PC3" adapters in applications where a port of the V75 will look like a modem connection when a computer or terminal is connected to the port. Some terminals and popular communications software packages require that DCD is "high" for a connection to be completed. Refer to Figure 33 if your computers/terminals have DB-25 male connectors or to Figure 34 if your computers/terminals have DE-9 connectors. Insert drawings of the 25 and 9 pin PC3 adapters
20
Page 33
M SERIES DAC CABLING ____________________________________________________________________________
Refer to the following modular adapter drawing (Figure 35) to interface modems to the V74 or V75 module. Insert the 25 pin md4 adapter Refer to the modular adapter drawing (Figure 36) below to connect an EIA-232 serial printer to the V74 or V75 module. Insert the 25 pin pr2 adapter
IMPORTANT: When BayTech modular adapters are used as given in Figures 31-36, a crossed 8-wire modular cable is required. Do not use 4wire modular cabling. Insert the crossed cable drawing
14.1.5
V75 EIA-422 CABLING
The cable required to connect an EIA-422 device to the V75 module using EIA-422 serial interface must have TX+ wired to RX+ (and vice versa), TX- wired to RX- (and vice versa), HSO wired to HSI (and vice versa), and the grounds connected. Please see Figure 37. V75 (EIA-422) RJ-45
Equipment Connections
1 HSO 2 GND 3 TX+ 4 TX5 RX6 RX+ 7 GND 8 HSI
HSI GND RX+ RXTXTX+ GND HSO
Figure 37: V75 EIA-422 Connection
21
Page 34
M SERIES DAC CABLING ____________________________________________________________________________
NOTE: The HSO, HSI, and GND signals do not need to be connected if you are not using hardware handshake lines. 14.3 V87 CABLING INFORMATION The V87 module has four ports that are user selectable as EIA-422 or EIA-485 serial interface. Ports on the V87 module use the following pins and signals for communication:
V87 PINOUT INFORMATION PIN
SERIAL INTERFACE
DIRECTION
DESCRIPTION
EIA-422
EIA-485
1
HSO
HSO
Output
Handshake Out. Used to enable or disable the receiving of characters
2
GND
GND
----
Signal Ground
3
TX+
TX+/RX+
Output Output/Input
422 - Transmit Data (+) 485 - Transmit/Receive Data (+)
4
TX-
TX-/RX-
Output Output/Input
422 - Transmit Data (-) 485 - Transmit/Receive Data (-)
5
RX-
NU
Input/----
232 - Receive Data (-) 485 - Not Used
6
RX+
NU
Input/----
422 - Receive Data (+) 485 - Not Used
22
Page 35
M SERIES DAC CABLING ____________________________________________________________________________ 7
GND
8
HSI
14.3.1
V87 SERIAL INTERFACE SELECTION
HSI
----
Signal Ground
Input
Handshake In. Used to enable or disable the transmitting of characters
The desired serial interface is selected by positioning jumpers on the main board of the module for each individual port. Please refer to Section 14.2.3 (V75 EIA-422 Cabling) for cabling information if using EIA-422 serial interface (default). If you wish to change one or more of the ports to operate using a different serial interface, please use the following procedure: a.
IMPORTANT: If the V87 module is installed in the base unit chassis, remove power from the unit by positioning the On/Off switch to "0" (off) and unplugging the power cord from the AC outlet. Remove the module by unscrewing the two straight slot screws securing it to the back panel and pulling the module out.
b.
Refer to Figure 39 on the following page and locate the four six-position jumper locations for serial interface selection. The jumper locations are marked on the assembly drawing for serial interface selection as JP5 for Port 1, JP8 for Port 2, JP11 for Port 3, and JP14 for Port 4.
c.
Each port is configurable for EIA-422 or EIA-485 serial interface by installing a four-position jumper to either the 422 or 485 position as marked on the board. The center row of pins for each port are occupied by two of the jumper positions and the row of pins for either 422 or 485 are occupied by the other two positions of this jumper. NOTE: A termination resistor is installed by default. You can remove the termination resistor for each individual port by moving JP4, JP7, JP1, or JP13 away from the R/T position for Ports 1, 2, 3, or 4 respectively.
d.
Install the V87 module into the base unit chassis (see Section 4.5).
Insert the v87 mechanical drawing
14.3.2
V87 EIA-485 CABLING
23
Page 36
M SERIES DAC CABLING ____________________________________________________________________________
The cable required to connect an EIA-485 device to the V87 module using EIA-485 serial interface must have TX+/RX+ wired to the TX+/RX+ line of your equipment, TX-/RX- wired to TX-/RX-, HSO wired to HSI (and vice versa), and the grounds connected. Please see Figure 40. V87 (EIA-485) RJ-45 1 HSO 2 GND 3 TX+/RX+ 4 TX-/RX7 GND 8 HIS
Equipment Connections HSI GND TX+/RX+ TX-/RXGND HSO
Figure 40: V87 EIA-422 Connection NOTE: The HSO, HSI, and GND signals do not need to be connected if you are not using hardware handshake lines.
RJ-45 CABLES AND ADAPTERS IMPORTANT: All RPC models have an RJ-45 port for connecting to a local EIA-232 device such as a computer terminal or external modem. Most serial computers do not have RJ-45 connections; therefore, an adapter is provided with this unit to convert from a DE-9 connector to an RJ-45 connector (BayTech Part No. 9FRJ45PC-1). An adapter to convert from a DB-25 connector to an RJ-45 connector is also available from BayTech, upon request (BayTech Part No. 25FRJ45PC-1).
24
Page 37
M SERIES DAC CABLING ____________________________________________________________________________
Figure 1: RJ-45 receptacle
Figure 2: RJ-45 plug
The RPC RJ-45 control port uses the following signals: EIA-232 RJ-45 PIN/SIGNAL DEFINITION Pin
EIA-232 Signal
Direction
Description
1
DTR
Output
+10V when activated by DCD. Toggles on logout for modem disconnect.
2
GND
----
Signal Ground
3
RTS
Output
+10V when powered is applied, not used as a handshake line
4
TX
Output
Transmit Data (data out)
5
RX
Input
Receive Data (data in)
6
N/C
N/C
No Connection
7
GND
-------
Signal Ground
8
DCD
Input
DCD into the RPC/Not used on RPC-2 MD01
Modem Communications: A modem can be connected to the EIA-232 serial port by using a 25MRJ45MD-8 adapter (Figure 6). Several types of modem adapters are available from BayTech. Contact an applications engineer for help in choosing the correct adapter.
25
Page 38
M SERIES DAC CABLING ____________________________________________________________________________
RJ-45
1
BLUE
2
ORANGE
3
BLACK
4
RED
5 6
1
DCD
2
RX
3
TX
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
FEMALE DE-9
GREEN YELLOW
7
BROWN
8
GRAY
Figure 5: Computer/Terminal Adapter BayTech Part No. 9FRJ45PC-1 Crossed RJ-45 cable is required
Figure 7: Crossed 8-pin Modular Cable BayTech Part No. RJ08X007 (7 feet)
IMPORTANT: Crossed RJ-45 cables are required when modular connectors are used, as shown in Figures 4 – 6, or to interface the RPC to another BayTech product with modular connectors, such as the DS-Series data switch.
26
Page 39
M SERIES DAC CABLING ____________________________________________________________________________
V77 Pinout The V77 ADM-1 is installed in the M Series chassis as described in the installation section of this manual. NOTE: The V77 ADM-1 cannot be installed as Module 1. If a V77 ADM-1 is removed from a module slot and a different V77 ADM-1 is installed in that location, the newly installed module acquires the previous module's configuration. Moving a V77 ADM-1 to a different module location requires reconfiguration because the configuration parameters are stored as a function of slot location and module type. The configuration information does not stay with a relocated module. IMPORTANT: You must install jumper JP1 to use +10V range. First, remove the ADM-1 from the M Series chassis. Next, locate JP1 in Appendix B and install a jumper connector on JP1. Once the ADM-1 has been installed in the M Series chassis, connect a cable with a DB-25 male connector to the input connector, J2. Determine if you will be using single-ended or differential inputs. Singled-ended operation allows up to 16 inputs using grounds of the same potential. Differential operation allows up to 8 inputs using different reference polarities. Configure your input cable as shown below for single-ended operation or for differential operation.
Input
Pin # Pin #
Input
DI Channel #
27
Page 40
M SERIES DAC CABLING ____________________________________________________________________________ Ground
1 14 10 & 22 Ground 2 15 9 & 21 Channel 8 3 16 8 & 20 Channel 7 4 17 7 & 19 Channel 6 5 18 6 & 18 Channel 5 6 19 5 & 17 Channel 4 7 20 4 & 16 Channel 3 8 21 3 & 15 Channel 2 9 22 + Channel 1 10 23 Polarity Ground 11 24 Ground 12 25 Ground 13
Ground
1
Channel 16
2
Channel 15
3
Channel 14
4
Channel 13
5
Channel 12
6
Channel 11
7
Channel 10
8
Channel 9 Ground Ground Ground
Single-ended Input Connection
Differential Input Connections
IMPORTANT: If you are connecting multiple single-ended devices, it is imperative all the grounds returns are at the same potential or erroneous operation could result. If a channel is not connected to an external circuit, it should be terminated to ground or programmed as inactive (see Section 5.1.5.4). This prevents the presentation or reporting of erroneous data from unused inputs. V78
Pinout
The V78 CRM-1 is installed in the M Series chassis as described in the installation section of this manual. NOTE: The V78 CRM-1 cannot be installed as Module 1. If a V78 CRM-1 is removed from a module slot and a different V78 CRM-1 is installed in that location, the newly installed module acquires the previous module's configuration. Moving an V78 CRM-1 to a different module location requires reconfiguration because the configuration parameters are stored as a function of slot location and module type. The configuration information does not stay with a relocated module.
28